This page has only limited features, please log in for full access.

Dr. Friedrich Idam
ICOMOS

Basic Info

Basic Info is private.

Research Keywords & Expertise

0 Building Analysis
0 Building Materials
0 Building Physics
0 Wood Technology
0 Industrial Archaeology

Honors and Awards

The user has no records in this section


Career Timeline

The user has no records in this section.


Short Biography

The user biography is not available.
Following
Followers
Co Authors
The list of users this user is following is empty.
Following: 0 users

Feed

Aufsatz
Published: 03 February 2021 in Bauphysik
Reads 0
Downloads 0

Das Ende des 19. Jahrhunderts errichtete Burgtheater in Wien ist eines der bedeutendsten Sprechtheater Europas. Es verfügt über eine aus der Errichtungszeit stammende Luftbrunnenanlage zur Frischluftversorgung und Konditionierung des Zuschauerhauses. Dabei wird Frischluft im nahegelegenen Volksgarten angesaugt und über einen unterirdischen Gang und Bodenauslässe in den Zuschauerraum geführt. Warme, verbrauchte Luft wird über die Decke des Zuschauerhauses und eine drehbare Öffnung auf dem Dach des Theaters abgeführt. Im Rahmen der vorliegenden Untersuchung wurden an maßgeblichen Stellen des Belüftungssystems Sensoren zur Überwachung von Lufttemperatur, Luftgeschwindigkeit und Luftfeuchtigkeit platziert. Schließlich wurden Optimierungspotenziale in der Betriebssteuerung und eine adiabate Luftkühlung durch Wasservernebelung evaluiert. Es konnten dabei erfolgsversprechende Handlungsoptionen zur nachhaltigen Konditionierung des Burgtheaters formuliert werden.

ACS Style

DI (Fh) DI Dr. Günther Kain; DI Dr. Friedrich Idam; Alfons Huber; DI Markus Goldsteiner. Luftbrunnenanlage des Burgtheaters Wien: Nachhaltige Klimatisierungsstrategien. Bauphysik 2021, 43, 1 -11.

AMA Style

DI (Fh) DI Dr. Günther Kain, DI Dr. Friedrich Idam, Alfons Huber, DI Markus Goldsteiner. Luftbrunnenanlage des Burgtheaters Wien: Nachhaltige Klimatisierungsstrategien. Bauphysik. 2021; 43 (1):1-11.

Chicago/Turabian Style

DI (Fh) DI Dr. Günther Kain; DI Dr. Friedrich Idam; Alfons Huber; DI Markus Goldsteiner. 2021. "Luftbrunnenanlage des Burgtheaters Wien: Nachhaltige Klimatisierungsstrategien." Bauphysik 43, no. 1: 1-11.

Journal article
Published: 17 September 2020 in Applied Sciences
Reads 0
Downloads 0

Wooden shingles are a traditional roofing material on many culturally important building artifacts. Currently, the roof space of many traditional buildings is used for residential purposes and, consequently, cold roof constructions with ventilation layers are applied. In this study, it is evaluated whether the moisture content of wooden shingles is adversely affected by such constructions, compared with unvented shingle roofs over cold attics and whether a temporary closing of the ventilation gaps at the eaves contributes to a lower wood moisture content. Various sensors were installed in and around a building with wooden shingles on a ventilated roof and temperature, air moisture, and air speed in the ventilation layer were measured throughout a year. The findings show that the air speed in the ventilation layer can be adjusted from 0.06 to 0.25 m/s depending on the layout of the eaves. A hygrothermal model was applied to evaluate the effects of different ventilation operation modes and cardinal orientations of the roof on the moisture content of the wooden shingles. The results show that roof ventilation results in a 1% lower shingle moisture content on average than an unventilated roof over a cold attic. Finally, it is shown that the wood moisture content repeatedly reaches dangerous levels above 25% throughout a year, which is worse on north-facing roofs and, hence, measures to increase the dry-out are relevant.

ACS Style

Günther Kain; Friedrich Idam; Franz Federspiel; Roman Réh; Ľuboš Krišťák. Suitability of Wooden Shingles for Ventilated Roofs: An Evaluation of Ventilation Efficiency. Applied Sciences 2020, 10, 6499 .

AMA Style

Günther Kain, Friedrich Idam, Franz Federspiel, Roman Réh, Ľuboš Krišťák. Suitability of Wooden Shingles for Ventilated Roofs: An Evaluation of Ventilation Efficiency. Applied Sciences. 2020; 10 (18):6499.

Chicago/Turabian Style

Günther Kain; Friedrich Idam; Franz Federspiel; Roman Réh; Ľuboš Krišťák. 2020. "Suitability of Wooden Shingles for Ventilated Roofs: An Evaluation of Ventilation Efficiency." Applied Sciences 10, no. 18: 6499.

Journal article
Published: 16 April 2020 in Sustainability
Reads 0
Downloads 0

Properly designed wooden truss bridges are environmentally compatible construction systems. The sharp decline in the erection of such structures in the past decades can be led back to the great effort needed for design and production. Digital parametric design and automated prefabrication approaches allow for a substantial improvement of the efficiency of design and manufacturing processes. Thus, if combined with a constructive wood protection following traditional building techniques, highly efficient sustainable structures are the result. The present paper describes the conceptual design for a wooden truss bridge drawn up for the overpass of a two-lane street crossing the university campus of one of Vienna’s main universities. The concept includes the greening of the structure as a shading design element. After an introduction, two Austrian traditional wooden bridges representing a good and a bad example for constructive wood protection are presented, and a state of the art of the production of timber trusses and greening building structures is given as well. The third part consists of the explanation of the boundary conditions for the project. Subsequently, in the fourth part, the conceptual design, including the design concept, the digital parametric design, the optimization, and the automated prefabrication concept, as well as the potential greening concept are discussed, followed by a summary and outlook on future research.

ACS Style

Benjamin Kromoser; Martin Ritt; Alexandra Spitzer; Rosemarie Stangl; Friedrich Idam. Design Concept for a Greened Timber Truss Bridge in City Area. Sustainability 2020, 12, 3218 .

AMA Style

Benjamin Kromoser, Martin Ritt, Alexandra Spitzer, Rosemarie Stangl, Friedrich Idam. Design Concept for a Greened Timber Truss Bridge in City Area. Sustainability. 2020; 12 (8):3218.

Chicago/Turabian Style

Benjamin Kromoser; Martin Ritt; Alexandra Spitzer; Rosemarie Stangl; Friedrich Idam. 2020. "Design Concept for a Greened Timber Truss Bridge in City Area." Sustainability 12, no. 8: 3218.

Journal article
Published: 08 August 2019 in Bauphysik
Reads 0
Downloads 0
ACS Style

Günther Kain; Friedrich Idam; Sarah Tonini; Angelika Wimmer. Torfmoos (Sphagnum) – historisches Erfahrungswissen und neue Einsatzmöglichkeiten für ein Naturprodukt. Bauphysik 2019, 41, 199 -204.

AMA Style

Günther Kain, Friedrich Idam, Sarah Tonini, Angelika Wimmer. Torfmoos (Sphagnum) – historisches Erfahrungswissen und neue Einsatzmöglichkeiten für ein Naturprodukt. Bauphysik. 2019; 41 (4):199-204.

Chicago/Turabian Style

Günther Kain; Friedrich Idam; Sarah Tonini; Angelika Wimmer. 2019. "Torfmoos (Sphagnum) – historisches Erfahrungswissen und neue Einsatzmöglichkeiten für ein Naturprodukt." Bauphysik 41, no. 4: 199-204.

Article
Published: 03 April 2017 in Bauphysik
Reads 0
Downloads 0

Historische Kastenfenster stehen noch immer in Verwendung, werden aber seit den 1980er Jahren vermehrt durch sogenannte Thermofenster aus Holz, Metall oder Kunststoff ersetzt. Als Hauptargument für den Fenstertausch wird neben der Haltbarkeit der Oberflächenbeschichtung vor allem der hohe Wärmedurchgang bei Kastenfenstern ins Treffen geführt. Dabei werden aber für diese historischen Fenster nicht Messergebnisse am realen Bestand, sondern normativ festgelegte Default-Werte herangezogen. Diese Default-Werte betragen allerdings das Drei- bis Vierfache der Laborwerte der industriell gefertigten Thermofenster. Um den tatsächlichen Wärmedurchgang bei Kastenfenstern bestimmen zu können, wurde an der Höheren Technischen Bundeslehranstalt (HTBLA) in Hallstatt/Oberösterreich die Entwicklung eines Messverfahrens in Angriff genommen, das an Ort und Stelle am realen Objekt einsetzbar ist. Die erste Messreihe legt den Schluss nahe, dass der reale Wärmedurchgang bei Kastenfenstern deutlich niedriger liegt, als die Default-Werte vorgeben. Thermal conductivity of box-type windows – an in-situ evaluation concept for historical buildings. Historic box-type windows are still in use, but are, starting with the 1980ies, increasingly replaced by insulating glass windows made from wood, metal, or plastic. Primary argument for a window change is the durability of the surface coating and the high heat loss with box-type windows. Historic windows are thereby not evaluated with real, experimental values, but are characterized by default-values. These values are three to four times as high as the heat transfer values of modern insulating glass windows measured in the laboratory. In order to determine the real heat transfer values of box-type windows, a measuring system is developed at the Higher Technical College in Hallstatt, which can be applied in-situ the real object. First results suggest that the real heat transfer through box-type windows is significantly lower than assumed.

ACS Style

Günther Kain; Florian Gschwandtner; Friedrich Idam. Der Wärmedurchgang bei Doppelfenstern - Konzept zur In-situ-Bewertung historischer Konstruktionen. Bauphysik 2017, 39, 144 -147.

AMA Style

Günther Kain, Florian Gschwandtner, Friedrich Idam. Der Wärmedurchgang bei Doppelfenstern - Konzept zur In-situ-Bewertung historischer Konstruktionen. Bauphysik. 2017; 39 (2):144-147.

Chicago/Turabian Style

Günther Kain; Florian Gschwandtner; Friedrich Idam. 2017. "Der Wärmedurchgang bei Doppelfenstern - Konzept zur In-situ-Bewertung historischer Konstruktionen." Bauphysik 39, no. 2: 144-147.