Sonodynamic therapy is an effective treatment for eliminating tumor cells by irradiating sonosentitizer in a patient’s body with higher penetration ultrasound and inducing the free radicals. Titanium dioxide has attracted the most attention due to its properties among many nanosensitizers. Hence, in this study, carbon doped titanium dioxide, one of inorganic materials, is applied to avoid the foregoing, and furthermore, carbon doped titanium dioxide is used to generate ROS under ultrasound irradiation to eliminate tumor cells. Spherical carbon doped titanium dioxide nanoparticles are synthesized by the sol-gel process. The forming of C-Ti-O bond may also induce defects in lattice which would be beneficial for the phenomenon of sonoluminescence to improve the effectiveness of sonodynamic therapy. By dint of DCFDA, WST-1, LDH and the Live/Dead test, carbon doped titanium dioxide nanoparticles are shown to be a biocompatible material which may induce ROS radicals to suppress the proliferation of 4T1 breast cancer cells under ultrasound treatment. From in vivo study, carbon doped titanium dioxide nanoparticles activated by ultrasound may inhibit the growth of the 4T1 tumor, and it showed a significant difference between sonodynamic therapy (SDT) and the other groups on the seventh day of the treatment.
1 March 2001 in Journal of Microelectromechanical Systems
A prototype contact-type micro piezoresistive shear-stress sensor that can be utilized to measure the shear stress between skin of stump and socket of above-knee (AK) prosthesis was designed, fabricated and tested. Micro-electro-mechanical system (MEMS) technology has been chosen for the design because of the low cost, small size and adaptability to this application. In this paper, the finite element method (FEM) package ANSYS has been employed for the stress analysis of the micro shear-stress sensors. The sensors contain two transducers that will transform the stresses into an output voltage. In the developed sensor, a 3000/spl times/3000/spl times/300 /spl mu/m/sup 3/ square membrane is formed by bulk micromachining of an n-type [100] monolithic silicon. The piezoresistive strain gauges were implanted with boron ions with a dose of 10/sup 15/ atoms/cm/sup 2/. Static characteristics of the shear sensor were determined through a series of calibration tests. The fabricated sensor exhibits a sensitivity of 0.13 mV/mA-MPa for a 1.4 N full scales shear force range and the overall mean hysteresis error is than 3.5%. In addition, the results simulated by FEM are validated by comparison with experimental investigations.
Nerve conduction block using high-intensity focused ultrasound (HIFU) has been conducted with nerves of mixed fibres in normal animal models. This study tested the feasibility and safety of HIFU for sensory nerve conduction block in diabetic neuropathic nerves to determine its potential for pain relief. Diabetes was induced in Sprague–Dawley rats using streptozotocin, and HIFU at 2.68 MHz was used for the block. This study consisted of two sections, in vitro and in vivo. For the in vitro experiments, the entire contiguous sciatic–sural nerves were obtained. Compound action potentials and sensory action potentials were recorded in the sciatic and sural nerves, respectively. For the in vivo experiments, compound muscle action potentials (CMAPs) were recorded from the gastrocnemius muscles. All data were expressed as median (range). The in vitro results showed that HIFU temporarily inhibited sensory action potentials of the control and diabetic rat nerves to 33.9 (8.2) and 14.0 (10.7)% of the baseline values, respectively, whereas the compound action potentials were suppressed to 53.6 (8.4) and 76.2 (7.5)% of baseline, respectively. The in vivo results showed that HIFU acutely blocked CMAPs to 32.9 (12.6) and 19.9 (10.9)% of baseline in control and diabetic rat nerves, respectively. Measurements of CMAPs and histological exanmination were used for indirect assessment of the safety of the HIFU technique. High-intensity focused ultrasound safely and reversibly suppressed nerve conduction in diabetic rat nerves when the stimulation parameters were appropriate. The results suggest that HIFU may have potential to block sensory nerves reversibly and provide peripheral pain relief.
1 January 2015 in Ultrasound in Medicine & Biology