Bernhard Meyer

Prof. Bernhard Meyer

Technical University of Munich (TUM)
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2010 in Spine
Verified
Journal Article
Closed access
DDDennis P. Devito
Dennis P. Devito
LKLeon Kaplan
Leon Kaplan
RDRupert Dietl
Rupert Dietl
MPMichael Pfeiffer
Michael Pfeiffer
DHDale Horne
Dale Horne
MSMoshe Shoham
Moshe Shoham
Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.

1 April 2012 in Spine
Verified
Journal Article
Closed access
FRFlorian Ringel
Florian Ringel
CSCarsten Stüer
Carsten Stüer
ARAndreas Reinke
Andreas Reinke
APAlexander Preuss
Alexander Preuss
MBMichael Behr
Michael Behr
BMBernhard Meyer
Bernhard Meyer
Single-center prospective randomized controlled study. To evaluate the accuracy of robot-assisted (RO) implantation of lumbar/sacral pedicle screws in comparison with the freehand (FH) conventional technique. SpineAssist is a miniature robot for the implantation of thoracic, lumbar, and sacral pedicle screws. The system, studied in cadaver and cohort studies, revealed a high accuracy, so far. A direct comparison of the robot assistance with the FH technique is missing. Patients requiring mono- or bisegmental lumbar or lumbosacral stabilization were randomized in a 1:1 ratio to FH or RO pedicle screw implantation. Instrumentation was performed using fluoroscopic guidance (FH) or robot assistance. The primary end point screw position was assessed by a postoperative computed tomography, and screw position was classified (A: no cortical violation; B: cortical breach <2 mm; C: ≥2 mm to <4 mm; D: ≥4 mm to <6 mm; E: ≥6 mm). Secondary end points as radiation exposure, duration of surgery/planning, and hospital stay were assessed. A total of 298 pedicle screws were implanted in 60 patients (FH, 152; RO, 146). Ninety-three percent had good positions (A or B) in FH, and 85% in RO. Preparation time in the operating room (OR), overall OR time, and intraoperative radiation time were not different for both groups. Surgical time for screw placement was significantly shorter for FH (84 minutes) than for RO (95 minutes). Ten RO screws required an intraoperative conversion to the FH. One FH screw needed a secondary revision. In this study, the accuracy of the conventional FH technique was superior to the RO technique. Most malpositioned screws of the RO group showed a lateral deviation. Attachment of the robot to the spine seems a vulnerable aspect potentially leading to screw malposition as well as slipping of the implantation cannula at the screw entrance point.

1 May 2015 in JAMA Otolaryngology–Head & Neck Surgery
Verified
Journal Article
Open access
PDF file
IMIsabelle Mosnier
Isabelle Mosnier
JBJean-Pierre Bebear
Jean-Pierre Bebear
MMMathieu Marx
Mathieu Marx
BFBernard Fraysse
Bernard Fraysse
ETEric Truy
Eric Truy
OSOlivier Sterkers
Olivier Sterkers
Large prospective studies have established an independent association between hearing impairment and cognitive decline.1,2 Individuals with mild to severe hearing loss have a 2- to 5-fold increased risk of developing dementia compared with those with normal hearing.1 Moreover, neuroimaging studies3,4 report an association between peripheral hearing impairment and temporal lobe cortex and whole brain atrophy. A combination of several interdependent mechanisms could account for this association, such as vascular risk factors, neurodegenerative processes affecting both peripheral auditory pathways and the cerebral cortex, social isolation, and reduced cognitive stimulation. Based on these reports, hearing rehabilitation using conventional hearing aids has logically been proposed as a treatment to help improve neurocognitive performance; however, the impact of the rehabilitation generated controversial results, with a beneficial effect reported in only half of the elderly groups presented in the 6 published analyses.5-10

1 May 2013 in Neurosurgery
Verified
Journal Article
Closed access
PDF file
TPThomas Picht
Thomas Picht
Sandro M KriegSandro M Krieg
Sandro M Krieg
Nico SollmannNico Sollmann
Nico Sollmann
JRJudith Rösler
Judith Rösler
BNBirat Niraula
Birat Niraula
FRFlorian Ringel
Florian Ringel
BACKGROUND:. Navigated transcranial magnetic stimulation (nTMS) is increasingly used in presurgical brain mapping. Preoperative nTMS results correlate

8 July 2022 in Science
Verified
Journal Article
Closed access
SLSahil Loomba
Sahil Loomba
JSJakob Straehle
Jakob Straehle
VGVijayan Gangadharan
Vijayan Gangadharan
NHNatalie Heike
Natalie Heike
AKAbdelrahman Khalifa
Abdelrahman Khalifa
MHMoritz Helmstaedter
Moritz Helmstaedter
The human cerebral cortex houses 1000 times more neurons than that of the cerebral cortex of a mouse, but the possible differences in synaptic circuits between these species are still poorly understood. We used three-dimensional electron microscopy of mouse, macaque, and human cortical samples to study their cell type composition and synaptic circuit architecture. The 2.5-fold increase in interneurons in humans compared with mice was compensated by a change in axonal connection probabilities and therefore did not yield a commensurate increase in inhibitory-versus-excitatory synaptic input balance on human pyramidal cells. Rather, increased inhibition created an expanded interneuron-to-interneuron network, driven by an expansion of interneuron-targeting interneuron types and an increase in their synaptic selectivity for interneuron innervation. These constitute key neuronal network alterations in the human cortex.

4 April 2010 in Nature Genetics
Verified
Journal Article
Open access
PDF file
KYKatsuhito Yasuno
Katsuhito Yasuno
KBKaya Bilguvar
Kaya Bilguvar
PBPhilippe Bijlenga
Philippe Bijlenga
Siew-Kee LowSiew-Kee Low
Siew-Kee Low
BKBoris Krischek
Boris Krischek
MGMurat Günel
Murat Günel
Murat Gunel and colleagues report a genome-wide association study for intracranial aneurysm and identify risk variants near RBBP8, CNNM and STARD13. Saccular intracranial aneurysms are balloon-like dilations of the intracranial arterial wall; their hemorrhage commonly results in severe neurologic impairment and death. We report a second genome-wide association study with discovery and replication cohorts from Europe and Japan comprising 5,891 cases and 14,181 controls with ∼832,000 genotyped and imputed SNPs across discovery cohorts. We identified three new loci showing strong evidence for association with intracranial aneurysms in the combined dataset, including intervals near RBBP8 on 18q11.2 (odds ratio (OR) = 1.22, P = 1.1 × 10−12), STARD13-KL on 13q13.1 (OR = 1.20, P = 2.5 × 10−9) and a gene-rich region on 10q24.32 (OR = 1.29, P = 1.2 × 10−9). We also confirmed prior associations near SOX17 (8q11.23–q12.1; OR = 1.28, P = 1.3 × 10−12) and CDKN2A-CDKN2B (9p21.3; OR = 1.31, P = 1.5 × 10−22). It is noteworthy that several putative risk genes play a role in cell-cycle progression, potentially affecting the proliferation and senescence of progenitor-cell populations that are responsible for vascular formation and repair.