Andrea Montisci

Dr. Andrea Montisci

Division of Cardiothoracic Intensive Care, ASST Spedali Civili di Brescia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2018 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
MMMassimo Meco
Massimo Meco
Andrea MontisciAndrea Montisci
Andrea Montisci
AMAntonio Miceli
Antonio Miceli
PPPaolo Panisi
Paolo Panisi
FDFrancesco Donatelli
Francesco Donatelli
MGMattia Glauber
Mattia Glauber
Background: Aortic stenosis is the most common valvular disease and has a dismal prognosis without surgical treatment. The aim of this meta‐analysis was to quantitatively assess the comparative effectiveness of the Perceval (LivaNova) valve versus conventional aortic bioprostheses. Methods and Results: A total of 6 comparative studies were identified, including 639 and 760 patients who underwent, respectively, aortic valve replacement with the Perceval sutureless valve (P group) and with a conventional bioprosthesis (C group). Aortic cross‐clamping and cardiopulmonary bypass duration were significantly lower in the P group. No difference in postoperative mortality was shown for the P and C groups (2.8% versus 2.7%, respectively; odds ratio [OR]: 0.99 [95% confidence interval ( CI ), 0.52–1.88]; P =0.98). Incidence of postoperative renal failure was lower in the P group compared with the C group (2.7% versus 5.5%; OR: 0.45 [95% CI , 0.25–0.80]; P =0.007). Incidence of stroke (2.3% versus 1.7%; OR: 1.34 [95% CI , 0.56–3.21]; P =0.51) and paravalvular leak (3.1% versus 1.6%; OR : 2.52 [95% CI , 0.60–1.06]; P =0.21) was similar, whereas P group patients received fewer blood transfusions than C group patients (1.16±1.2 versus 2.13±2.2; mean difference: 0.99 [95% CI , −1.22 to −0.75]; P =0.001). The incidence of pacemaker implantation was higher in the P than the C group (7.9% versus 3.1%; OR : 2.45 [95% CI , 1.44–4.17]; P =0.001), whereas hemodynamic Perceval performance was better (transvalvular gradient 23.42±1.73 versus 22.8±1.86; mean difference: 0.90 [95% CI , 0.62–1.18]; P =0.001), even during follow‐up (10.98±5.7 versus 13.06±6.2; mean difference: −2.08 [95% CI , −3.96 to −0.21]; P =0.030). We found no difference in 1‐year mortality. Conclusions: The Perceval bioprosthesis improves the postoperative course compared with conventional bioprostheses and is an option for high‐risk patients.

1 January 2020 in Journal of Cardiothoracic and Vascular Anesthesia
Verified
Journal Article
Closed access
MMMassimo Meco
Massimo Meco
Andrea MontisciAndrea Montisci
Andrea Montisci
EGEnrico Giustiniano
Enrico Giustiniano
MGMassimiliano Greco
Massimiliano Greco
FPFederico Pappalardo
Federico Pappalardo
GAGiovanni Albano
Giovanni Albano

1 March 2018 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
LBLars Mikael Broman
Lars Mikael Broman
MMMaximilian V. Malfertheiner
Maximilian V. Malfertheiner
Andrea MontisciAndrea Montisci
Andrea Montisci
Federico PappalardoFederico Pappalardo
Federico Pappalardo
Veno-venous extracorporeal membrane oxygenation (VV ECMO) is a rescue treatment for acute respiratory distress syndrome (ARDS) failing protective mechanical ventilation. It temporarily provides proper gas exchange: hypoxia is treated by adjusting the blood flow rate and fraction in spired oxygen over the ventilator (FiO2) on the extracorporeal membrane oxygenation (ECMO) circuit while CO2 removal is regulated by the ECMO fresh gas flow. Therefore, ventilator settings can be gradually reduced allowing the lungs to rest and recover. Nowadays, indications for ECMO referral and implantation are clearly formulated; on the contrary, little evidence currently exists to guide the process of weaning from ECMO support, especially concerning the timing during the course of lung healing. Therefore, indications to stop ECMO are less well standardized so that in clinical trials extracorporeal assistance is generally continued until lung recovery, with neither specific nor homogenous criteria for withdrawal. Notably, in almost all papers dealing with data on VV ECMO support, the management of weaning and the weaning procedure itself are not described. The aim of this paper is to make a picture of VV ECMO weaning, as it is performed in three European large volume intensive care units (ICUs) which represent referral centers for VV ECMO treatment. We focused on data concerning the timing of VV ECMO weaning and parameters at the time of weaning, in order to assess adequacy and safety of VV ECMO removal.

1 November 2020 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
AAAlberto Aiolfi
Alberto Aiolfi
TBTullio Biraghi
Tullio Biraghi
Andrea MontisciAndrea Montisci
Andrea Montisci
GBGianluca Bonitta
Gianluca Bonitta
GMGiancarlo Micheletto
Giancarlo Micheletto
DBDavide Bona
Davide Bona

1 May 2015 in ASAIO Journal
Verified
Journal Article
Closed access
Andrea MontisciAndrea Montisci
Andrea Montisci
GMGiulia Maj
Giulia Maj
AZAlberto Zangrillo
Alberto Zangrillo
DWDario Winterton
Dario Winterton
Federico PappalardoFederico Pappalardo
Federico Pappalardo
Venovenous extracorporeal membrane oxygenation (VV ECMO) in acute respiratory distress syndrome (ARDS) is currently a widely used therapeutic strategy. However, patients are often still hypoxemic despite complete ECMO support. The major determinants of peripheral oxygen saturation (SpO2) during VV ECMO are pump flow, degree of recirculation, patient's systemic venous return and its oxygen saturation, hemoglobin concentration and residual lung function. Current guidelines state that the support can be considered adequate when the patient's SpO2 is equal or greater than 80%, but a possible objection could be that such a value of O2-tension may be too low and may worsen the patient's prognosis. Moving from the pathophysiology of hypoxemia during VV ECMO, this review focuses on recirculation of blood and on the possible strategies to minimize it, on the pharmacologic modulation of intrapulmonary shunt and on the questions related to management of ECMO flow and the risks and benefits of permissive hypoxemic states. Transfusional strategy during VV ECMO, administration of neuromuscular blocking agents and sedatives, therapeutic hypothermia, and prone positioning is also reviewed. The potential advantages of β-blockers are discussed. Finally, transition from VV ECMO to venoarterial ECMO (VA ECMO) or a hybrid configuration is also examined.

11 September 2017 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
MMMassimo Meco
Massimo Meco
AMAntonio Miceli
Antonio Miceli
Andrea MontisciAndrea Montisci
Andrea Montisci
FDFrancesco Donatelli
Francesco Donatelli
SCSilvia Cirri
Silvia Cirri
MGMattia Glauber
Mattia Glauber
OBJECTIVES: The aim of this meta-analysis was to compare outcomes of patients undergoing transcatheter aortic valve implantation (TAVI) with those undergoing surgical aortic valve replacement using sutureless valves. METHODS: A systematic review and meta-analysis in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was performed. RESULTS: No randomized controlled trials were identified. Six comparative studies using propensity score matching met the inclusion criteria. This meta-analysis identified 1462 patients in that 731 patients underwent surgical aortic valve replacement using sutureless valves (SU) and 731 patients underwent a TAVI. The 30-day or in-hospital mortality was lower in the SU group [odds ratio (OR) 0.54, 95% confidence interval (CI) 0.36–0.80; P = 0.003]. In the TAVI group, the incidence of postoperative stroke was higher (OR 0.36, 95% CI 0.17–0.79; P = 0.01). The incidence of moderate or severe paravalvular regurgitation was higher in the TAVI group (OR 0.22, 95% CI 0.14–0.35; P = 0.001). There were neither differences in the postoperative renal failure (OR 1.44, 95% CI 0.46–4.58; P = 0.53) nor in the number of patients requiring postoperative pacemaker implantation (OR 1.06, 95% CI 0.54–2.08; P = 0.86). Patients in the SU group required more transfusions (OR 4.47, 95% CI 2.77–7.21; P = 0.0001), whereas those in the TAVI group had higher major vascular complications (OR 0.06, 95% CI 0.01–0.25; P = 0.0001). Intensive care unit stay was not different (mean difference 0.99, 95% CI − 1.22 to 1.40; P = 0.53). One-year survival was better in the SU group (Peto OR 0.35, 95% CI 0.18–0.67; P = 0.001), as was the 2-year survival (Peto OR 0.38, 95% CI 0.17–0.86; P = 0.001). CONCLUSIONS: Surgical aortic valve replacement using sutureless valves is associated with better early and mid-term outcomes compared with TAVI in high- or intermediate-risk patients.