This paper presents a modified small-signal model of a voltage source inverter (VSI) and a voltage source converter (VSC) that captures model nonlinearities such as deadtime and modulation effects that were not presented in the literature. Previous research has concentrated on developing compensation methods for these types of phenomena in a switching model, but very little on predicting them. In this paper, the small-signal model of the VSI in literature is used, and the different phenomena are then incorporated into the model to get a complete one. In addition, the effect of voltage and current feedback control is also analyzed. The output impedance of the VSI is derived with the modified small-signal model, compared to the conventional one and validated with switching model and experimental results.
7 September 2020 in IEEE Internet of Things Journal
Unlike conventional servers housed in a centralized and secured indoor environment (e.g., data centers), Internet-of-Things (IoT) devices such as sensor/actuator are geographically distributed and may be closely located to the physical systems where IoT devices are utilized. However, the resource-constrained nature of IoT devices limits their capacity to deploy sophisticated security solutions. The proposed approach assumes that a device can be compromised and hence, the need to be able to automatically isolate the compromised device(s). In order to enforce security policies even when devices are compromised, we propose using blockchain in the monitoring framework. Unlike existing centralized or distributed security solutions (which do not consider the possibility that the solutions themselves can be compromised), the proposed blockchain-based framework can enforce the security policies as long as a majority of the devices are not compromised. By employing the permissioned blockchain (Hyperledger Fabric) and add-on hardware modules, the proposed framework offers significantly lower latency and overhead compared to permissionless blockchain frameworks (e.g., Ethereum) and allows existing IoT devices to join the framework without modification.
28 July 2017 in IEEE Transactions on Industry Applications
This paper presents a universal flying restart strategy for scalar (V/f) controlled induction machines. The proposed method performs a frequency search to estimate the rotor speed, and applies the correct frequency and voltage to minimize the inrush current during the restart. This method uses the measured phase current and the motor nameplate parameters, thus making the approach ideal for scalar-controlled motor drives. In addition, the restart algorithm provides controllable restart dynamics, independent of the motor parameters. The main advantages of this method include simple and cost effective implementation without the need for additional sensors, and controllable restart dynamics independent of the motor parameters. Beyond the development of the algorithm, we consider implementation issues to provide a general guideline for the application of the developed algorithm.
Electric vehicles (EVs) play a crucial role in achieving sustainability goals, mitigating energy crises, and reducing air pollution. However, their rapid adoption poses significant challenges to the power grid, particularly during peak charging periods, necessitating advanced load management strategies. This study introduces an artificial intelligence (AI)-integrated optimal charging framework designed to facilitate fast charging and mitigate grid stress by smoothing the “duck curve”. Data from Caltech’s Adaptive Charging Network (ACN) at the National Aeronautics and Space Administration (NASA) Jet Propulsion Laboratory (JPL) site was collected and categorized into day and night patterns to predict charging duration based on key features, including start charging time and energy requested. The AI-driven charging strategy developed optimizes energy management, reduces peak loads, and alleviates grid strain. Additionally, the study evaluates the impact of integrating 1.5 million, 3 million, and 5 million EVs under various AI-based charging strategies, demonstrating the framework’s effectiveness in managing large-scale EV adoption. The peak power consumption reaches around 22,000 MW without EVs, 25,000 MW for 1.5 million EVs, 28,000 MW for 3 million EVs, and 35,000 MW for 5 million EVs without any charging strategy. By implementing an AI-driven optimal charging optimization strategy that considers both early charging and duck curve smoothing, the peak demand is reduced by approximately 16% for 1.5 million EVs, 21.43% for 3 million EVs, and 34.29% for 5 million EVs.
The growing penetration of distributed energy resources (DERs) has increased the complexity of the power system due to their intermittent characteristics and lower inertial response, such as photo voltaic (PV) systems and wind turbines. This restructuring of power system has considerable effect on transient response of the system resulting in inter area oscillations, less synchronized coupling and power swings. Furthermore the concept of being distributed itself and generating electricity from multiple locations in power system makes the transient impact of DERs even worse by raising issues such as reverse power flows. This paper investigated some impacts of the changing nature of power system which are limiting the large scale integration of DERs. In addition a solution to increase the inertial response of the system is addressed by adding virtual inertia to the inverter based DERs in power system. The proposed control resulted in increasing the stability margin and tracking the rated frequency of the system. The injected synchronized active power to the system prevents the protection relays from tripping by improving the rate of change of frequency. The proposed system operation is implemented on a sample power grid comprising of generation, transmission and distribution and results are verified experimentally through the Opal-RT real-time simulation system.