Cao Zhongliang

Mr. Cao Zhongliang

School of Mechanical Engineering, Jiangsu Institute of Technology, Changzhou
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
CZCao Zhongliang
Cao Zhongliang
DMDong Mingjun
Dong Mingjun
Kailei LiuKailei Liu
Kailei Liu
HFHongya Fu
Hongya Fu
Under the effect of different process parameters, the temperature field inside the thermoplastic fiber is very complex and directly affects the fusion quality between the resins. Considering the heat transfer behavior of thermoplastic fiber polyether ether ketone (PEEK) as the research object, a mathematical model of heat transfer in the thermoplastic composite fiber placement with the relevant boundary conditions was established. Ansys Parametric Design Language (APDL) was used to generate the finite element model and simulate the transient process, not only to explore the influence of various process parameters on the temperature field, but also to build an online temperature field measurement system. The influence rules of placement process parameters and mold initial temperature with respect to the temperature field in the first layer were obtained. Combining the relationship between heating temperature and placement speed, when the first layer was laid, the placement process temperature could be quickly reached by low speed and high temperature. The temperature data were collected by the online detection system. Compared with the temperature data from the simulation, the error was below 8%, which verified the correctness of the heat transfer model. The academic research results will lay a theoretical foundation for the thermoplastic fiber placement.

7 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
QHQingming Hu
Qingming Hu
JGJianhua Guo
Jianhua Guo
CZCao Zhongliang
Cao Zhongliang
HJHongyuan Jiang
Hongyuan Jiang
Enhancing mixing is of significant importance in microfluidic devices characterized by laminar flows and low Reynolds numbers. An asymmetrical induced charge electroosmotic (ICEO) vortex pair generated on the herringbone floating electrode can disturb the interface of two-phase fluids and deliver the fluid transversely, which could be exploited to accomplish fluid mixing between two neighbouring fluids in a microscale system. Herein we present a micromixer based on an asymmetrical ICEO flow induced above the herringbone floating electrode array surface. We investigate the average transverse ICEO slip velocity on the Ridge/Vee/herringbone floating electrode and find that the microvortex generated on the herringbone electrode surface has good potential for mixing the miscible liquids in microfluidic systems. In addition, we explore the effect of applied frequencies and bulk conductivity on the slip velocity above the herringbone floating electrode surface. The high dependence of mixing performance on the floating electrode pair numbers is analysed simultaneously. Finally, we investigate systematically voltage intensity, applied frequencies, inlet fluid velocity and liquid conductivity on the mixing performance of the proposed device. The microfluidic micromixer put forward herein offers great opportunity for fluid mixing in the field of micro total analysis systems.

7 January 2021 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
Kailei LiuKailei Liu
Kailei Liu
Shangpeng KangShangpeng Kang
Shangpeng Kang
CZCao Zhongliang
Cao Zhongliang
RLRongsheng Liu
Rongsheng Liu
ZDZhaoxuan Ding
Zhaoxuan Ding
The electrohydraulic leveling system of the hydraulic press can realize automatic leveling control function. In order to eliminate the eccentric load force accurately, an electrohydraulic leveling system with independent metering is designed. Quasi-static behavior analysis of the leveling cylinders output forces performance is applied to the electrohydraulic leveling system with independent metering. The angle and force hybrid control method is proposed, and then the AMESim/Simulink cosimulation model is built. The HSIC controller and PID controller are used in the simulation, respectively. Simulation results show that both of the leveling angle control and leveling cylinders output forces control can be realized, simultaneously, and the HSIC controller has higher rapidity and smaller overshoot than the PID controller.

24 February 2018 in Polymer Composites
Verified
Journal Article
Closed access
PDF file
CZCao Zhongliang
Cao Zhongliang
HFHongya Fu
Hongya Fu
Zhenyu HanZhenyu Han
Zhenyu Han

30 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
CZCao Zhongliang
Cao Zhongliang
DGDengke Guo
Dengke Guo
HFHongya Fu
Hongya Fu
Zhenyu HanZhenyu Han
Zhenyu Han
By changing the placement angle of the placement path, the fiber direction can be controlled and adjusted to change the load distribution in the laminate, and the stress and natural frequency performances of the laminate can then be altered to finally obtain laminates with desired mechanical properties. In this paper, the finite element analysis model of variable-stiffness laminates is established based on the fiber placement reference path defined by the Bezier curve method. Based on the analysis of the mechanical properties of the thermoplastic fiber variable-angle laminates obtained by variable-angle trajectory planning, the changes in the stress and deformation of the thermoplastic fiber variable-angle laminate with the connection point parameter β under a compressive load are analyzed. The influence of the parameter β on the static performances of the variable-angle laminates is studied. The simulation results indicate that the maximum stress of the laminate increases first and then decreases as the parameter β increases and reaches the maximum value when the parameter β is 0.5. The minimum stress also shows the same trend as that of the maximum stress and reaches the minimum value when the connection point parameter β is 0.3. The deformation of the variable-angle laminates varies with the change of the connection point parameter β. The maximum deformation increases at first and then decreases for the laminate with the parameter β increasing and reaches the maximum value when the parameter β is 0.8. The minimum deformation of the laminate decreases initially and then increases as the connection point parameter β increases and reaches the minimum value when the parameter β is 0.6. The deformation gradually decreases from the upper and lower ends to the middle, and the deformation area has a symmetrical form. The initial regular rectangular area gradually changes to an elliptical distribution and the area of maximum deformation gradually decreases.

28 February 2025 in Journal of Thermoplastic Composite Materials
Verified
Journal Article
Closed access
CZCao Zhongliang
Cao Zhongliang
XGXiangrui Geng
Xiangrui Geng
HZHao Zhu
Hao Zhu
KHKejun Hu
Kejun Hu
Aiming at the problem of water vapor condensation caused by the unit cell sealing of traditional grid core materials, a thermoplastic CF/PEEK sandwich structure with cross-grid cores was proposed. The finite element analysis model of high-speed impact and progressive damage of sandwich panels with cross-grid cores is established. The model is used to study the high-speed impact response characteristics of sandwich panels, to explore the influence of panel geometric parameters on its high-speed impact resistance, and to discuss the energy absorption of panels at different impact velocities. In addition, compared with the traditional honeycomb sandwich panel, the advantages and disadvantages of energy absorption efficiency and impedance impact are compared. The results show that the thermoplastic CF/PEEK sandwich structures with cross-grid cores were proposed to have an attenuation effect on the impact and can provide some protection for the object located behind the panel. The main contributors to its impact energy absorption are the front and rear panels. Once a certain speed limit is reached, the energy absorption rate of the front and rear panels is basically the same. The maximum strain at the front of the sandwich panel is about 5%. In addition, the sandwich structure has a better impedance effect on high-speed impact load.