The present paper presents the main results obtained by the Italian Working Group on Natural Esters recently promoted by the University of Rome "La Sapienza", the Firefighters Authority, the Department for Geological Survey of Italy (ISPRA) and the Department of Technological Innovations, Safety of Product, Plants and Anthropic Settlements of the National Institute for Insurance against Accidents at Work (INAIL). This WG on Natural Esters was set up at the beginning of 2016 with the aim of establish the effective possibility of reducing the risks to human health and the environment, through increased spread of innovative transformers insulated with natural esters. In the paper are presented and discussed the following topics: main properties of natural esters and mineral oils; fire risk evaluation of distribution and transmission transformers, including an experimental comparison of fire behavior of natural esters and mineral insulating oils; risk evaluation and different remedial solution for leakage and spill of natural esters and mineral insulating oils.
23 January 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
IEC 60156 and IEC 60897 were standardized with the purpose of evaluating the breakdown voltage of liquid dielectrics both under AC and impulse voltages. AC breakdown voltage determination is a simple method but only able to provide information on the presence of contaminants. The limit of this test is the large scatter in the results and, for this reason, this IEC standard has been recently revised. Impulse breakdown voltage determination allows discrimination of different dielectric liquids, also in terms of their chemical composition. This test has only limited application because of the dimensions of the high voltage generator. The present paper shows a comparison among breakdown voltages of various mineral oils and natural esters under both AC and impulse voltages. The paper presents also an effort to describe how these two tests may reveal the electrical performance of the dielectric liquid under test.
10 November 2015 in IEEE Transactions on Dielectrics and Electrical Insulation
There are several reasons to test the breakdown voltage of insulating liquids: acceptance tests on new deliveries, testing of treated liquids prior to or during filling into electrical equipment, and monitoring and maintaining oil-filled apparatus in service. Among others, the test for the determination of breakdown voltage at 50 or 60 Hz is one of the most important. In fact, it is worldwide accepted that this test gives quickly very useful information even if mainly related with moisture and particle content than the intrinsic properties of the insulating liquids. This test is standardized by IEC and ASTM but has some limitations in terms of the statistical scatter of mean value of the breakdown voltage. The present paper presents an improvement on the scatter of the mean values of the breakdown voltage by increasing the number of requested shots and discarding the most disperse results. In addition, it is presented as a revised test cell having stirring device on the top and round edges at the bottom may further reduce the standard deviation of the same breakdown voltage. Others experimental parameters which may still influence the scatter of the same standardized test are also examined and discussed.
The present paper reports an experimental investigation on the thermal behavior of medium voltage underground cables laid in different types of soils and under different conditions of the ambient temperatures. The same paper shows as thermal degradation of the insulating system of the cables and their joints can become more consistent and faster due to the effect of the continuously overheating due to the ambient temperatures and to the thermal resistivity of the soil of higher values. An other source of thermal degradation of the cables and their joints may be indicated in the fault currents affecting the metallic shields in systems operating with a compensated neutral connection to ground. In particular, in these systems the fault current is lasted for a time of some tens of seconds to allow a faster localization of the failure, through the automatic sectioning switches. During this time, currents flow through the metallic shields of the cables, overheating the same shields especially in correspondence of pour connections which may be present inside the joints. In case that the single-fault-to-ground evolves in a double-fault-to-ground the same shield will be interested by much higher current (short-circuit) which will create a deeper degradation of the semiconductive compounds and the insulation located nearby the metallic shields. The paper also presents the results of visual inspections of failed cable joints, due to thermal causes. Based on these considerations, important solutions may be indicated to reduce the failure rate of the MV electrical system allowing improvements in the overall power quality of the entire electrical systems.