1 August 2005 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
MDM. Duval
M. Duval
James DukarmJames Dukarm
James Dukarm
Dissolved gas analysis (DGA) is widely used to detect incipient faults in oil-filled electrical equipment. There is always some degree of inaccuracy in laboratory dissolved-gas measurements, especially at low gas concentrations, which affects gas ratios and other diagnostic calculations. This paper examines the measurement inaccuracy problem in detail using recent CIGRE data. It shows how proper allowance for this inaccuracy can improve transformer condition assessment and diagnosis by DGA.

20 December 2011 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
FJFredi Jakob
Fredi Jakob
PNPaul Noble
Paul Noble
James DukarmJames Dukarm
James Dukarm
Dissolved gas analysis (DGA) has been used to classify the type and severity of faults in transformers. The method commonly used to identify severity is to measure the total fault gas concentration and its rate of change, without regard to the relative concentrations of individual gases. Thermodynamic analysis indicates that the energy required to form gases increases in the order CH4 <; C2H6 ≤ CO ≤ C2H4 <; H2 ≪ C2H2. Based on these results, an energy-weighted dissolved gas analysis (EWDGA) is proposed, where concentrations of individual gases are multiplied by a weighting factor that is proportional to the energy required to produce each gas. Statistical calculations are used to show that EWDGA is more sensitive to high-energy faults than simple DGA, hence minimizing the damage caused by those faults.

30 December 2002
Verified
Conference Paper
Closed access
James DukarmJames Dukarm
James Dukarm
Dissolved-gas analysis (DGA) is widely used for detection and diagnosis of incipient faults in large oil-filled transformers. Many factors contribute to extreme "noisiness" in the data and make early fault detection and diagnosis difficult. This paper shows how fuzzy logic and neural networks are being used to automate standard DGA methods and improve their usefulness for power transformer fault diagnosis. The use of neural networks for DGA-with or without fuzzy logic-is discussed, and some related work is described briefly.

23 March 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
FJFredi Jakob
Fredi Jakob
James DukarmJames Dukarm
James Dukarm
Conventional practice for transformer dissolved gas analysis (DGA) is to use concentrations of several fault gases, with or without total dissolved combustible gas, for evaluating apparent fault severity. We suggest a simpler approach based on the normalized energy intensity (NEI), a quantity related directly to fault energy dissipated within the transformer. DGA fault severity scoring based on NEI is shown to be sensitive to all IEC fault types and to be more responsive to shifts in the relative concentrations of the fault gases than scoring based on fault gas concentrations. Instead of eight or more gas concentration limits, NEI scoring requires only two or three limits that can be empirically derived to suit local requirements for any population of mineral-oil-filled power transformers.

1 January 1987 in Colloquium Mathematicum
Verified
Journal Article
Open access
PDF file
James DukarmJames Dukarm
James Dukarm

7 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
James DukarmJames Dukarm
James Dukarm
Zachary DraperZachary Draper
Zachary Draper
TPTomasz Piotrowski
Tomasz Piotrowski
A Duval triangle is a diagram used for fault type identification in dissolved-gas analysis of oil-filled high-voltage transformers and other electrical apparatus. The proportional concentrations of three fault gases (such as methane, ethylene, and acetylene) are used as coordinates to plot a point in an equilateral triangle and identify the fault zone in which it is located. Each point in the triangle corresponds to a unique combination of gas proportions. Diagnostic pentagons published by Duval and others seek to emulate the triangles while incorporating five fault gases instead of three. Unfortunately the mapping of five gas proportions to a point inside a two-dimensional pentagon is many-to-one; consequently, dissimilar combinations of gas proportions are mapped to the same point in the pentagon, resulting in mis-diagnosis. One solution is to replace the pentagon with a four-dimensional simplex, a direct generalization of the Duval triangle. In a comparison using cases confirmed by inspection, the simplex outperformed three ratio methods, Duval triangle 1, and two pentagons.