1 June 2003 in Biomaterials
15 October 2014 in Journal of Dental Research
One of the leading causes for the failure of dental composite restorations is secondary caries. Effectively inhibiting cariogenic biofilms and reducing secondary caries could extend the service life of composite restorations. Dental composites releasing antibacterial agents such as chlorhexidine (CHX) have shown biofilm-inhibitory efficacy, but they usually have poor physical and mechanical properties. Herein, we present a study of a new method to encapsulate and release CHX from dental composite using mesoporous silica nanoparticles (MSNs). SBA-15 MSNs were synthesized according to a reported procedure. CHX (62.9 wt%) was encapsulated into dried MSN from 0.3 M CHX ethanol solution. The dental composites containing 0% (control), 3%, 5%, and 6.3% CHX or the same amounts of CHX entrapped in MSN (denoted as [email protected]) were fabricated with methacrylate monomers and silanized glass fillers (CHX or [email protected] + glass filler particle = 70 wt%). The monomer mixture consisted of bisphenol A glycidyl methacrylate (BisGMA), hexanediol dimethacrylate (HDDMA), ethoxylated bisphenol A dimethacrylate (EBPADMA), and urethane dimethacrylates (UEDMA) at a weight ratio of 40:30:20:10. The composites were tested for CHX release and recharge, flexural strength and modulus (at 24 hr and 1 mo), surface roughness, in vitro wear, and antibacterial activity against Streptococcus mutans and Lactobacillus casei (in both planktonic growth and biofilm formation). The results showed that the composites with [email protected] largely retained mechanical properties and smooth surfaces and showed controlled release of CHX over a long time. In contrast, the composites with directly mixed CHX showed reduced mechanical properties, rough surfaces, and burst release of CHX in a short time. The composites with CHX either directly mixed or in MSN showed strong inhibition to S. mutans and L. casei. This research has demonstrated the successful application of MSNs as a novel nanotechnology in dental materials to inhibit oral biofilm without sacrificing materials’ mechanical properties and surface integrity.
24 March 2012 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
1 April 2012 in Dental Materials
1 November 2006 in Dental Materials
1 January 2006 in Journal of Esthetic and Restorative Dentistry
Background: In Class II composite restorations, the adhesive covering the gingival floor of the deep cavity preparation is 2 to 8 mm from the light guide and may not be adequately cured with a typical 10‐second curing time. Purpose: The purpose of this study was to evaluate the dentin bond strengths of resin composite when the curing light guide (quartz‐tungsten‐halogen light) was placed at various distances and to investigate the relationships between radiant exposure, degree of conversion, and shear bond strength. Materials and Methods: Single Bond (3M ESPE, St. Paul, MN, USA) was placed onto the dentin following the manufacturer's directions. Four groups of 10 teeth were cured for 20 seconds through a 0, 2.3, 4.6, or 6.9 mm spacer. Two other groups of 10 teeth were cured through a 4.6 mm spacer for 40 seconds and 60 seconds, respectively. Z100 resin composite (3M ESPE) was placed over the cured adhesive and polymerized at the same distance as the adhesive. After 24 hours of storage in water, the shear bond strengths were tested. The irradiance through each spacer was measured using a digital radiometer. The degree of conversion of the adhesive was determined by near infrared spectroscopy. The data were analyzed using analysis of variance and Tukey‐B post hoc tests. Results: Dentin shear bond strengths decreased significantly with increasing distance, but they increased significantly when the curing time increased from 20 to 40 or 60 seconds. There is a linear correlation between shear bond strength, degree of conversion, and logarithm (radiant exposure). Conclusion: Increasing curing time can compensate for the decreased bond strength owing to a decreased irradiance associated with increased curing distance. CLINICAL SIGNIFICANCE Under the conditions of this study, when curing the adhesives in deep proximal boxes with a quartz‐tungsten‐halogen light, the curing time should be increased to 40 to 60 seconds to ensure optimal polymerization.