Benjamin Heidt

Mr. Benjamin Heidt

Maastricht University, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
BHBenjamin Heidt
Benjamin Heidt
Williane SiqueiraWilliane Siqueira
Williane Siqueira
KEKasper Eersels
Kasper Eersels
HDHanne Diliën
Hanne Diliën
BGBart Van Grinsven
Bart Van Grinsven
TCThomas Cleij
Thomas Cleij
Point of care (PoC) diagnostics are at the focus of government initiatives, NGOs and fundamental research alike. In high-income countries, the hope is to streamline the diagnostic procedure, minimize costs and make healthcare processes more efficient and faster, which, in some cases, can be more a matter of convenience than necessity. However, in resource-limited settings such as low-income countries, PoC-diagnostics might be the only viable route, when the next laboratory is hours away. Therefore, it is especially important to focus research into novel diagnostics for these countries in order to alleviate suffering due to infectious disease. In this review, the current research describing the use of PoC diagnostics in resource-limited settings and the potential bottlenecks along the value chain that prevent their widespread application is summarized. To this end, we will look at literature that investigates different parts of the value chain, such as fundamental research and market economics, as well as actual use at healthcare providers. We aim to create an integrated picture of potential PoC barriers, from the first start of research at universities to patient treatment in the field. Results from the literature will be discussed with the aim to bring all important steps and aspects together in order to illustrate how effectively PoC is being used in low-income countries. In addition, we discuss what is needed to improve the situation further, in order to use this technology to its fullest advantage and avoid “leaks in the pipeline”, when a promising device fails to take the next step of the valorization pathway and is abandoned.

1 August 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JLJoseph W. Lowdon
Joseph W. Lowdon
KEKasper Eersels
Kasper Eersels
RRRenato Rogosic
Renato Rogosic
TBTine Boonen
Tine Boonen
BHBenjamin Heidt
Benjamin Heidt
TCThomas J. Cleij
Thomas J. Cleij

1 March 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JLJoseph W. Lowdon
Joseph W. Lowdon
KEKasper Eersels
Kasper Eersels
RRRenato Rogosic
Renato Rogosic
BHBenjamin Heidt
Benjamin Heidt
HDHanne Diliën
Hanne Diliën
TCThomas J. Cleij
Thomas J. Cleij

10 November 2020 in Molecules
Verified
Journal Article
Open access
PDF file
JLJoseph W. Lowdon
Joseph W. Lowdon
KEKasper Eersels
Kasper Eersels
RCRocio Arreguin Campos
Rocio Arreguin Campos
MCManlio Caldara
Manlio Caldara
BHBenjamin Heidt
Benjamin Heidt
BGBart Van Grinsven
Bart Van Grinsven
The rapid sensing of drug compounds has traditionally relied on antibodies, enzymes and electrochemical reactions. These technologies can frequently produce false positives/negatives and require specific conditions to operate. Akin to antibodies, molecularly imprinted polymers (MIPs) are a more robust synthetic alternative with the ability to bind a target molecule with an affinity comparable to that of its natural counterparts. With this in mind, the research presented in this article introduces a facile MIP-based dye displacement assay for the detection of (±) amphetamine in urine. The selective nature of MIPs coupled with a displaceable dye enables the resulting low-cost assay to rapidly produce a clear visual confirmation of a target’s presence, offering huge commercial potential. The following manuscript characterizes the proposed assay, drawing attention to various facets of the sensor design and optimization. To this end, synthesis of a MIP tailored towards amphetamine is described, scrutinizing the composition and selectivity (ibuprofen, naproxen, 2-methoxphenidine, quetiapine) of the reported synthetic receptor. Dye selection for the development of the displacement assay follows, proceeded by optimization of the displacement process by investigating the time taken and the amount of MIP powder required for optimum displacement. An optimized dose–response curve is then presented, introducing (±) amphetamine hydrochloride (0.01–1 mg mL−1) to the engineered sensor and determining the limit of detection (LoD). The research culminates in the assay being used for the analysis of spiked urine samples (amphetamine, ibuprofen, naproxen, 2-methoxphenidine, quetiapine, bupropion, pheniramine, bromopheniramine) and evaluating its potential as a low-cost, rapid and selective method of analysis.

26 March 2020 in Physica Status Solidi (a)
Verified
Journal Article
Open access
PDF file
BHBenjamin Heidt
Benjamin Heidt
RRRenato Rogosic
Renato Rogosic
SBSilvio Bonni
Silvio Bonni
JPJuliette Passariello-Jansen
Juliette Passariello-Jansen
DDDavid Dimech
David Dimech
TCThomas J. Cleij
Thomas J. Cleij
In laboratory environments, 3D printing can be used for fast prototyping of assays and devices. Stereolithographic (SLA) 3D printers have been proven to be the best choice for most researchers due to their small feature size, which is achieved by selectively curing liquid resin using a laser with a small focal point and then forming consecutive layers out of cured polymer. However in microfluidic applications, where the limits of these machines are reached, the final results are influenced by many factors. In this work, the Form2 SLA printer is tested to show how to achieve the best printing results for the creation of microfluidic channels. Several test structures were designed and printed with embedded and open channels in different orientations, sizes and resins. Embedded channels significantly under performed when compared to open surface channels in terms of accuracy. Under the best printing conditions, 500 μm is the limit for embedded channels while the open surface channels showed good accuracy up to widths and depths of 250 μm

11 June 2018 in Nutrients
Verified
Journal Article
Open access
PDF file
KEKasper Eersels
Kasper Eersels
HDHanne Diliën
Hanne Diliën
JLJoseph W. Lowdon
Joseph W. Lowdon
ERErik Steen Redeker
Erik Steen Redeker
RRRenato Rogosic
Renato Rogosic
BGBart Van Grinsven
Bart Van Grinsven
Vitamin K was originally discovered as a cofactor required to activate clotting factors and has recently been shown to play a key role in the regulation of soft tissue calcification. This property of vitamin K has led to an increased interest in novel methods for accurate vitamin K detection. Molecularly Imprinted Polymers (MIPs) could offer a solution, as they have been used as synthetic receptors in a large variety of biomimetic sensors for the detection of similar molecules over the past few decades, because of their robust nature and remarkable selectivity. In this article, the authors introduce a novel imprinting approach to create a MIP that is able to selectively rebind vitamin K1. As the native structure of the vitamin does not allow for imprinting, an alternative imprinting strategy was developed, using the synthetic compound menadione (vitamin K3) as a template. Target rebinding was analyzed by means of UV-visible (UV-VIS) spectroscopy and two custom-made thermal readout techniques. This analysis reveals that the MIP-based sensor reacts to an increasing concentration of both menadione and vitamin K1. The Limit of Detection (LoD) for both compounds was established at 700 nM for the Heat Transfer Method (HTM), while the optimized readout approach, Thermal Wave Transport Analysis (TWTA), displayed an increased sensitivity with a LoD of 200 nM. The sensor seems to react to a lesser extent to Vitamin E, the analogue under study. To further demonstrate its potential application in biochemical research, the sensor was used to measure the absorption of vitamin K in blood serum after taking vitamin K supplements. By employing a gradual enrichment strategy, the sensor was able to detect the difference between baseline and peak absorption samples and was able to quantify the vitamin K concentration in good agreement with a validation experiment using High-Performance Liquid Chromatography (HPLC). In this way, the authors provide a first proof of principle for a low-cost, straightforward, and label-free vitamin K sensor.