Rui F. Martins

Prof. Dr. Rui F. Martins

NOVA School of Science and Technology (NOVA FCT), Caparica, Portugal
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Engineering Failure Analysis
Verified
Journal Article
Closed access
JGJoao Gomes
Joao Gomes
NGNarciso Gaivota
Narciso Gaivota
Rui F. MartinsRui F. Martins
Rui F. Martins
PSPaulo Silva
Paulo Silva

28 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
ESEmmanuel Silva
Emmanuel Silva
Duarte MarquesDuarte Marques
Duarte Marques
MPMário Rito Pereira
Mário Rito Pereira
VVVictor Talarico leal Vieira
Victor Talarico leal Vieira
MVMarco Versiani
Marco Versiani
The current study aimed to compare the F1 endodontic instruments from five different heat-treated rotary systems regarding their design, metallurgical properties, and mechanical performance. Five F1 root canal shaping instruments (ProTaper Gold [PTG], Premium Taper Gold, Go-Taper Flex, EdgeTaper Platinum, and Super Files Blue)—plus, a conventional ProTaper Universal (PTU)—which were evaluated regarding their design, nickel/titanium ratio, phase transformation temperatures, microhardness, cyclic fatigue, and torsional and bending strengths. Mood's median test was used for the statistical comparison with a significance set at 5%. The instruments were similar regarding the nickel/titanium ratio and overall design. Go-Taper Flex had the closest transformation temperatures to PTG. PTU and Go-Taper Flex had the highest microhardness (408.3 and 410.5 HVN). The time to fracture of Super Files Blue was three and seven times higher than PTG and PTU, respectively. No difference was observed in the maximum torque to fracture among PTG (1.30 N·cm) and the other systems, except for the Premium Taper Gold (1.05 N·cm) and Go-Taper Flex (1.10 N·cm). Significantly lower bending loads than PTG (269.2 gf) were observed for the EdgeTaper Platinum (158.3 gf) and Premium Taper Gold (103.5 gf) instruments. Super Files Blue outperformed PTG in the cyclic fatigue test, while EdgeTaper Platinum and Premium Taper Gold were more flexible. Premium Taper Gold and Go-Taper Flex showed lower torsional strength.

1 January 2015 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
HBHugo Bissig
Hugo Bissig
HPHarm Tido Petter
Harm Tido Petter
PLPeter Lucas
Peter Lucas
EBElsa Batista
Elsa Batista
EFEduarda Filipe
Eduarda Filipe
WSWouter Sparreboom
Wouter Sparreboom
Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.

3 June 2022 in Journal of Endodontics
Verified
Journal Article
Closed access
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
Rui F. MartinsRui F. Martins
Rui F. Martins
FFFrancisco Manuel Braz Fernandes
Francisco Manuel Braz Fernandes
ESEmmanuel J.N.L. Silva
Emmanuel J.N.L. Silva

25 January 2022 in International Journal of Fracture
Verified
Journal Article
Open access
PDF file
Wojciech MacekWojciech Macek
Wojciech Macek
Rui F. MartinsRui F. Martins
Rui F. Martins
RBRicardo Branco
Ricardo Branco
ZMZbigniew Marciniak
Zbigniew Marciniak
Mirosław SzalaMirosław Szala
Mirosław Szala
SWSebastian Wroński
Sebastian Wroński
The paper focuses on researching the effect of fatigue loading on metallic structure, lifetime, and fracture surface topographies in AISI H13 steel specimens obtained by selective laser melting (SLM). The topography of the fracture surfaces was measured over their entire area, according to the entire total area method, with an optical three-dimensional surface measurement system. The fatigue results of the SLM 3D printed steel specimens were compared with those reported for conventionally manufactured 13H steel. The investigation also considers the roughness of the specimens’ side surface. Moreover, the fractographic evaluation conducted using scanning electron microscopy confirms that the predominant fracture mechanism is transgranular fracture. Microtomography done after mechanical loading also showed the influence of the stress level on the porosity distribution. Both fractographic and Micro-CT investigations confirm that higher stresses result in coarser and much more uniform porosity observed in fractured samples. These comprehensive quantitative and qualitative fracture analyses are beneficial to predict the failure conditions of SLM steel parts, especially in the case of fatigue damage. From the quantitative analysis of the H13 SLM-manufactured fracture surface topography, it was possible to conclude that the larger the loadings acting on the specimen, the rougher the fracture surface because the ductile fracture mode dominates. It has also been proven that the porosity degree changes along the length of the sample for the most stressed specimens.

13 July 2022 in International Journal of Fatigue
Verified
Journal Article
Open access
Ricardo BrancoRicardo Branco
Ricardo Branco
Rui F. MartinsRui F. Martins
Rui F. Martins
JCJ.A.F.O. Correia
J.A.F.O. Correia
ZMZ. Marciniak
Z. Marciniak
WMW. Macek
W. Macek
JJJ. Jesus
J. Jesus