Shuguang Li

Prof. Shuguang Li

University of Nottingham, Nottingham, UK
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Composites Part A: Applied Science and Manufacturing
Verified
Journal Article
Open access
SLShuguang Li
Shuguang Li
ESElena Sitnikova
Elena Sitnikova
YLYuning Liang
Yuning Liang
AKAbdul-Salam Kaddour
Abdul-Salam Kaddour
This paper is to rationalise the empirical aspect of the Tsai-Wu failure criterion in the context of UD composites associated with the determination of the interactive strength property F12 based on the analytic geometry. It reveals that the condition of closed failure envelope cannot be satisfied by all UD composites and hence the restriction should be abandoned. Depending on the way the failure envelope opens, UD composites can be classified into two categories. (a) F12 can be determined uniquely using the conventional strength properties with an additional assumption that the material exhibits very high or infinite strength under triaxial compression at a specific stress ratio; or (b) The Tsai-Wu criterion leads to one of the two scenarios: either allowing infinite strength for an in-plane stress state or allowing infinite strength under triaxial stresses involving tension along fibres

22 October 2020 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
SLShuguang Li
Shuguang Li
The maximum strain failure criterion is unified with the maximum stress failure criterion, after exploring the implications of two considerations responsible for this: (1) the failure strains for the direct strain components employed in the maximum strain criterion are all defined under uniaxial stress states, not uniaxial strain states, and (2) the contributions to the strain in a direction as a result of the Poisson effect do not contribute to the failure of the material in that direction. Incorporating these considerations into the maximum strain criterion, the maximum stress criterion is reproduced. For 3D stress/strain state applications primarily, the unified maximum stress/strain criterion is then subjected to further rationalization in the context of transversely isotropic materials by eliminating the treatments that undermine the objectivity of the failure criterion. The criterion is then applied based on the maximum and minimum direct stresses, the maximum transverse shear stress and the maximum longitudinal shear stress as the invariants of the stress state, instead of the conventional stress components directly.

13 March 2015 in Journal of Engineering Mathematics
Verified
Journal Article
Closed access
PDF file
SLShuguang Li
Shuguang Li
LJL. F. C. Jeanmeure
L. F. C. Jeanmeure
QPQ. Pan
Q. Pan

1 July 2013 in Chinese Physics B
Verified
Journal Article
Closed access
PDF file
WQWei Qin
Wei Qin
SLShuguang Li
Shuguang Li
JXJian-Rong Xue
Jian-Rong Xue
XXXü-Jun Xin
Xü-Jun Xin
LZLei Zhang
Lei Zhang
This paper presents a theoretical study on a photonic crystal fiber plasmonic refractive index biosensor. The proposed photonic crystal fiber sensor introduces the concept of simultaneous detection with the linearly polarized and radially polarized modes because the sensing performance of the sensor based on both modes is relatively high, which will be useful for selecting the modes to make the detection accurately. The sharp single resonant peaks of the linearly polarized mode and radially polarized mode, are stronger and more sensitive to the variation of analyte refractive index than that of any other polarized mode in this kind of photonic crystal fiber. For linearly polarized mode and radially polarized mode, the maximum sensitivities of 10448.5 nm per refractive index unit and 8230.7 nm per refractive index unit can be obtained, as well as 949.8 and 791.4 for figure of merits in the sensing range of 1.33–1.45, respectively. Compared with the conventional Au-metalized surface plasmon resonance sensors, our device is better and can be applied as a biosensor.

1 June 2020 in Composites Part A: Applied Science and Manufacturing
Verified
Journal Article
Closed access
MXMingming Xu
Mingming Xu
ESElena Sitnikova
Elena Sitnikova
SLShuguang Li
Shuguang Li

1 September 2017 in Composites Science and Technology
Verified
Journal Article
Open access
ESElena Sitnikova
Elena Sitnikova
SLShuguang Li
Shuguang Li
DLDafei Li
Dafei Li
XYXiaosu Yi
Xiaosu Yi
In cross-ply laminates, the shape of delamination areas, which form due to low velocity impact, have two subtle features, which have been observed consistently in numerous experiments. Those are the pointed delamination tips and the intact zone between the lobes of delamination. However, there have not been any account available in the literature how they can be consistently captured through numerical modelling, and hence these features in published modelling results were often absent. It is the objective of this paper to identify the underlying modelling considerations so that these features can be captured with confidence. A key and unique reason has been identified in each case. Namely, inclusion of intra-laminar damage allows to reproduce the pointed delamination tips, while the gap between the lobes of delamination can be captured by models with sufficiently refined mesh, where friction between the laminas is taken into account. The capability of capturing these subtle features helps to raise the level of fidelity on the simulation of delamination due to impact