Marko Jankovec

Prof. Marko Jankovec

University of Ljubljana, Faculty of Electrical Engineering
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Energy & Environmental Science
Verified
Journal Article
Open access
PDF file
JZJianghui Zheng
Jianghui Zheng
WDWeiyuan Duan
Weiyuan Duan
YGYuzhen Guo
Yuzhen Guo
ZZZijun C. Zhao
Zijun C. Zhao
HYHaimang Yi
Haimang Yi
AHAnita W. Y. Ho-Baillie
Anita W. Y. Ho-Baillie

Tandem solar cells are promising for overcoming the theoretical single junction solar cell efficiency limit. Here we report an elegant approach to monolithically integrate perovskites and Si-heterojunction tandem solar cells using an ultra-thin indium tin oxide (ITO) interlayer. It is found that a 1.7 nm ITO interlayer is sufficient to provide the interfacing between the silicon and perovskite subcells with minimum parasitic resistance and efficient trap states for carrier recombination. Thinner ITO interlayers result in discontinuous films while thicker ITO interlayers with improved lateral conductivity are less effective in localising shunts especially for large (≥1 cm2) area tandem cells. Furthermore, it is found that a tandem cell with a 26 nm thick 〈p〉a-Si:H junction in the bottom cell performs better than that with a 13 nm thick junction. When combined with a 1.7 nm ultra-thin ITO layer and a front anti-reflection coating, our champion 1.0 cm2 cell achieved 27.2% power conversion efficiency (PCE) and a fill factor (FF) of 82.4% under reverse scan. This FF is the highest of any perovskite–Si tandem cell. The ultra-thin ITO layer is suitable for large area cells. 24.2% efficiency was demonstrated on an 11.8 cm2 cell. A 21.1% efficient 65.1 cm2 (∼4 inch round) cell was also fabricated. This representative cell shows negligible efficiency loss after 600 hours of continuous 1 sun illumination under MPP tracking. This work provides insights into the role of ultra-thin interfacing ITO layers for monolithic large-area perovskite–Si tandem cells.


6 December 2012 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
MHMatic Herman
Matic Herman
Marko JankovecMarko Jankovec
Marko Jankovec
Marko TopicMarko Topic
Marko Topic
High-efficiency solar cells and modules exhibit strong capacitive character resulting in limited speed of transient responses. A too fastI-Vcurve measurement can thus introduce a significant error due to its internal capacitances. This paper analyses theI-Vcurve error of a measured solar cell or module in light of scan time and irradiance level. It rests on a two-diode solar cell model extended by two bias-dependent capacitances, modelling the junction, and the diffusion capacitance. A method for determination of all extended model parameters from a quasistaticI-Vcurve and open-circuit voltage decay measurement is presented and validated. Applicability of the extended model and the developed parameter extraction method to PV modules is demonstrated and confirmed. SPICE simulations of the extended model are used to obtain theI-Vcurve error versus scan time dependence and theI-Vcurve hysteresis. Determination of the optimal scan time is addressed, and finally the influence of the irradiance level on theI-Vcurve scan time and error is revealed. The method is applied but is not limited to three different wafer-based silicon solar cell types.

13 July 2016 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
Marko JankovecMarko Jankovec
Marko Jankovec
FGFederico Galliano
Federico Galliano
EAEleonora Annigoni
Eleonora Annigoni
HLHeng Yu Li
Heng Yu Li
FSFanny Sculati-Meillaud
Fanny Sculati-Meillaud
Marko TopicMarko Topic
Marko Topic
A new in-situ moisture monitoring technique for photovoltaic (PV) modules is proposed using miniature digital humidity and temperature sensors. The sensors were embedded in three different ethylene-vinyl-acetate (EVA) stacks and proved to be resistant to lamination conditions. The fact that they are in direct contact to EVA does not affect their performance, since their saturated relative humidity (RH) reading is proportional to the external RH in the air. By exposing the sensors to elevated temperature and RH conditions, water vapor transmission rate of the backsheet and diffusion coefficient of the EVA can be determined. Obtained coefficients agree with reference values within their measurement uncertainties. Besides determining material moisture ingress properties, this monitoring technique is also applicable for long-term outdoor PV module monitoring. It shall provide valuable location and installation specific information of RH and temperature stress conditions, especially as feedback information to manufacturers of materials and PV modules.

7 October 2025 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
JZJianghui Zheng
Jianghui Zheng
GWGuoliang Wang
Guoliang Wang
Leiping DuanLeiping Duan
Leiping Duan
WDWeiyuan Duan
Weiyuan Duan
YJYang Jiang
Yang Jiang
AHAnita W. Y. Ho-Baillie
Anita W. Y. Ho-Baillie
Triple‐junction solar cells theoretically outperform their double-junction and single‐junction counterparts in power conversion efficiency, yet practical perovskite–perovskite–silicon devices have fallen short of both theoretical limits and commercial targets. To address surface defects in the top perovskite junction, we introduce a piperazine-1,4-diium chloride treatment, which replaces less stable lithium fluoride. For interfacing the top and middle perovskite junctions, we optimize the size of gold nanoparticles deposited on atomic layer-deposited tin oxide for best ohmic contacting with minimal optical losses. Applying these strategies, our champion 1-cm 2 triple‐junction cell achieved a third party-verified reverse‐scan power conversion efficiency of 27.06% with an open circuit voltage of 3.16 V. Scaling up to 16 cm 2 , the device produced a certified steady‐state power conversion efficiency of 23.3%. Device longevity also improved by eliminating methylammonium and incorporating rubidium into the perovskite bulk alongside the piperazine-1,4-diium chloride surface layer. An encapsulated 1-cm 2 cell retained 95% of its initial efficiency after 407 h at maximum power point and passed the IEC 61215 thermal cycling test. These results represent advancements towards efficient and stable perovskite–perovskite–silicon triple-junction solar cells.

29 April 2013 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
Marko JankovecMarko Jankovec
Marko Jankovec
Marko TopicMarko Topic
Marko Topic
Solar cells' temperature is a very important parameter that affects performance of photovoltaic (PV) modules since main electrical parameters of PV cells and modules are temperature dependent regardless the technology. The present study evaluates and compares different sensor types and mountings for long term outdoor temperature monitoring of PV modules along with a standardized method for determination of cell's temperature from open-circuit voltage. For that purpose, a special multicrystalline silicon PV module with miniature in situ Pt1000 temperature sensors was used for reference temperature measurement. On the back side of the PV module different temperature sensors were attached, including thermocouple (TC), platinum Pt1000 (PT) and digital temperature sensors DS18B20 (DS). All sensors except one were covered by a 1 cm thick insulation block. The whole setup was mounted on the outdoor PV testing site and all temperatures were monitored for several days with selection of different environmental conditions. On the basis of measurement results, deviations of different temperature sensors are investigated and compared to temperature calculated from open-circuit voltage measurement according to standard EN 60904-5. Among sensors attached at the back side, covered PT and TC sensors deliver the best results in range of 1–2 °C of lower temperature in average; while the covered DS sensor gives additional 1–2 °C underestimated temperature values. The worst measurement results demonstrate the PT sensor without insulation. All temperature sensors exhibit similar and adequate time response regarding the thermal capacitance of the PV module. DS sensors, although showing somewhat worse results, offer great advantages if several temperatures have to be acquired simultaneously and require very simple data acquisition equipment. They feature comparable measurement accuracy than commonly used Pt1000 temperature sensors if they are covered by insulation with 10 mm thick walls in lateral direction to avoid micro-environmental changes.

9 May 2024 in Advanced Energy Materials
Verified
Journal Article
Open access
MRMarko Remec
Marko Remec
ŠTŠpela Tomšič
Špela Tomšič
MKMark Khenkin
Mark Khenkin
QEQuiterie Emery
Quiterie Emery
JLJinzhao Li
Jinzhao Li
Marko TopicMarko Topic
Marko Topic
Perovskite‐based solar cells exhibit peculiar outdoor performance which is not yet fully understood. The results of outdoor tests may contain hidden, but valuable information that cannot be fully extracted from measurements alone. One such phenomenon is the effect of nighttime degradation and the subsequent light‐soaking recovery, which can take from a few hours in the morning up to the entire day. In this work, long‐term outdoor monitoring is combined with energy yield modeling to qualitatively and quantitatively investigate the effect of light‐soaking recovery in both single junction and tandem perovskite‐based devices. Following the novel methodology presented in this study, it is observed that the light‐soaking effect depends not only on the daily irradiation but also on the device temperature, and it can be described using a simple empirical formalism. Incorporating this dependency into the energy yield model results in an excellent agreement between the simulated and the measured outdoor data, which allows to perform long‐term prediction studies. The model estimates that the light‐soaking metastability effect decreases the attainable annual energy yield by up to ≈5% for the studied single junction devices, and for tandems by up to ≈3%, depending on the geographical location, and even more for non‐optimal device orientation.