omair shah

Dr. omair shah

sheri kashmir institute of medical sciences

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Indian Journal of Nephrology
Verified
Journal Article
Open access
OSomair shah
omair shah
TKTahir Khan
Tahir Khan
MBMudasir Bhat
Mudasir Bhat
NCNaseerA Choh
NaseerA Choh
SMShadab Maqsood
Shadab Maqsood
TSTahleelA Shera
TahleelA Shera
J Indian Prosthodont Soc, Official publication of Indian Prosthodontic Society

21 September 2021 in International Journal of Angiology
Verified
Journal Article
Closed access
PDF file
OSomair shah
omair shah
NCNaseer Choh
Naseer Choh
TSTahleel Shera
Tahleel Shera
FSFaiz Shera
Faiz Shera
TGTariq Gojwari
Tariq Gojwari
IRIrfan Robbani
Irfan Robbani
Amyloidosis is a systemic disease involving many organs. Cardiac involvement is a significant cause of morbidity and mortality in these patients. Diagnosis of cardiac amyloidosis is based on endomyocardial biopsy which however is invasive and associated with complications. Noninvasive methods of diagnosis include magnetic resonance imaging (MRI) with various methods and sequences involved. Our study aims at describing MRI features of cardiac amyloidosis including new imaging sequences and to prognosticate the patients based on imaging features. We included 35 patients with suspected cardiac amyloidosis who underwent MRI at our center over 4 years. All images were retrieved from our archive and assessed by an experienced radiologist. Common morphological features in our patients included increased wall thickness of left ventricle (LV) (16. 1 ± 4.1 mm), right ventricle (RV) (6.3 ± 1.1 mm), and interatrial septum (6.2 ± 0.8 mm). Global late gadolinium enhancement (LGE) (n = 21 [65%]) including subendocardial or transmural was the most common pattern followed by patchy enhancement. Global transmural LGE was associated with worse prognosis. Four types of myocardial nulling patterns were observed on postcontrast time to invert (TI) scout imaging: normal nulling pattern (myocardium nulls after blood and coincident with spleen) and abnormal nulling pattern (ANP) which is further divided into three types: Type 1—myocardium nulls before blood pool but coincident with spleen, Type 2—myocardium nulling coincident with blood but not coincident with spleen, and Type 3—features of both Type 1 and Type 2. Type 3 ANP was the most common (n = 23) nulling pattern in our patients. Cardiac MRI is an essential in noninvasive diagnosis of cardiac amyloidosis. Transmural global LGE serves as a poor prognosticator in these patients. “Three-tier” TI scout imaging is essential to avoid false-negative enhancement results. Type 3 ANP is the most specific nulling pattern in cardiac amyloidosis.

1 March 2021 in Galician Medical Journal
Verified
Journal Article
Open access
PDF file
OSomair shah
omair shah
FSFaiz Shera
Faiz Shera
NCNaseer Choh
Naseer Choh
TGTariq Gojwari
Tariq Gojwari
FSFahad Shafi
Fahad Shafi
MRMusadiq Rafiq
Musadiq Rafiq
The length of the styloid process varies greatly in different populations and depends on ethnicity and geographical background. The elongated styloid process may be associated with Eagle’s syndrome. Therefore, the mean normal length of the styloid process in different population groups needs to be calculated and the upper cutoff limit for elongated styloid process should be found. The objective of the research was to evaluate the styloid process length in the Kashmiri population using multidetector computed tomography. Materials and Methods. We retrospectively evaluated 304 patients who underwent computed tomography of the head and paranasal sinuses, and the mean styloid process length was calculated on both sides. The mean of three measurements of styloid process length was taken. The study population was grouped as follows: Group I included patients at the age of 21-30 years; Group II comprised patients at the age of 31-40 years; Group III included 68 patients at the age of 41-50 years; Group IV comprised patients > 50 years old. Results. The mean length of the styloid process in the studied population varied from 20 to 51 mm (mean 31.3 ± 4.5 mm). There was no significant difference in the length on both sides (p=0.835). The mean length of the styloid process was 30.1 ± 4.2 mm in females and 32.3 ± 4.8 mm in males (p< 0.034). The lengths of the styloid process in different age groups were as follows: in Group I - 30.9 ± 4.4 mm; in Group II - 31.2 ± 4.8 mm; in Group III - 31.6 ± 4.3 mm; in Group IV - 31.5 ± 4.5 mm. Conclusions. The mean length of the styloid process in our population was higher as compared to many other ethnic groups. The styloid process in males was longer. The elongated styloid process on computed tomography scan should not be labeled as Eagle’s syndrome unless clinical symptoms are present.

Verified
Journal Article
Open access
PDF file
FMFarooq Mir
Farooq Mir
ZRZahoor Raina
Zahoor Raina
OSomair shah
omair shah
TGTariq Gojwari
Tariq Gojwari
IRIrfan Robbani
Irfan Robbani
TSTahleel Shera
Tahleel Shera
The aim is to calculate sensitivity, specificity and diagnostic accuracy of Ultrasonography (USG) as a screening modality in evaluation of Menisco- Ligamentous injuries of knee joint with Magnetic Resonance Imaging (MRI)as gold standard for comparison.Patients with clinically suspected Menisco-Ligamentous injurieswere evaluated by USG initially followed by MRI on the same day. A total of 60 patients (50 males, 10 females) underwent USG and MRI. USG was done using high frequency probe (9-14 Hz) and all the injuries noted. USG of the normal knee was done for comparison. MRI with trauma protocol sequences was done on the same day. The accuracy of USG and MRI in diagnosis of menisco-ligamentous injuries was compared. Majority of the patients (50%) belonged to age group of 21-40 years. Most common injuries seen were medial meniscal tear followed by medial collateral ligament injury. The strength of agreement between USG and MRI was good with Diagnostic accuracy of USG ranging from 83.3% to 95% for different meniscal/ligamentous injuries.USG is an effective imaging modality with high accuracy in diagnosing menisco-ligamentous injuries. USG can act as an effective screening modality in closed knee trauma for evaluation of menisco- ligamentous injuries especially in resource constrained regions owing to its easy availability, portability and lower cost. MRI can be reserved for patients with suspicious USG and clinical findings.

1 March 2022 in Galician Medical Journal
Verified
Journal Article
Open access
PDF file
IZIshfaq Zargar
Ishfaq Zargar
IRIrfan Robanni
Irfan Robanni
OSomair shah
omair shah
TGTariq Gojwari
Tariq Gojwari
RRRiaz Rasool
Riaz Rasool
MWMunir Wani
Munir Wani
Background.The study was aimed at assessing the role of ultrasonography and multidetector computed tomography angiography in evaluating patients with suspected mesenteric ischemia, as well as assessing the effect of the time from presentation to management on mortality and morbidity. Materials and Methods. Patients with clinically suspected mesenteric ischemia underwent Doppler ultrasound and contrast-enhanced computed tomography. On ultrasonography, we assessed any filling defect in the superior mesenteric artery/vein, narrowing or occlusion of the proximal superior mesenteric artery, ascites, bowel wall thickening, and pneumatosis/portal venous gas. Computed tomography angiography was performed looking for any filling defect in the superior mesenteric artery/vein, superior mesenteric artery/vein calibre, bowel wall thickening, calibre and enhancement and pneumatosis/portal vein gas. Most of our patients underwent emergency surgery and the findings correlated with imaging. All the patients were divided into Group A (n=30) and Group B (n=17) based on the time from presentation to management: within 48 hours of presentation and 48 hours after presentation, respectively. Results. On computed tomography scan, mesenteric vascular involvement was seen in 27 (55%) patients, mesenteric/intestinal twist was observed in 12 (25%) patients, and non-occlusive mesenteric ischemia was found in 6% of patients. The computed tomography findings were found to have a sensitivity of 86%, a specificity of 94% and an accuracy of 90% in cases of mesenteric ischemia. Among 35 patients operated on, those presenting within 48 hours, had a significantly less mortality (63%) in comparison to those presenting after 48 hours (90%). Conclusions. Clinical, laboratory and ultrasound features are non-specific in diagnosing mesenteric ischemia. Computed tomography angiography is a sine qua non in mesenteric ischemia diagnosis. Patients with venous ischemia respond well to conservative management. Early intervention within the first 48 hours is associated with better prognosis.

1 January 2018 in Neurology India
Verified
Journal Article
Closed access
PDF file
OSomair shah
omair shah
WAWani Arif
Wani Arif
BMBashir Muiez
Bashir Muiez
SJSuhail Jan
Suhail Jan
DMDar Musaib
Dar Musaib
GTGojwari Tariq
Gojwari Tariq
Neurol India is an peer-reviewed biomedical periodical of Neurological Society of India.