Ibrahim A. Aljamaan

Dr. Ibrahim A. Aljamaan

Biomedical Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in IEEE Access
Verified
Journal Article
Open access
Ibrahim A. AljamaanIbrahim A. Aljamaan
Ibrahim A. Aljamaan
Ibraheem Al-NaibIbraheem Al-Naib
Ibraheem Al-Naib
Predicting the blood glucose level of type 1 diabetes mellitus of patients could prevent hypo/hyperglycemia incidents that are threats for the patients with this disease. A nonlinear system identification approach is proposed in this work to develop a mathematical model, which can be used to predict the blood glucose level over a given period with high accuracy. More specifically, the Hammerstein Box-Jenkins model is used to approximate the system, where two infinite impulse response filters represent the linear and noise processes, and a polynomial basis function represents the nonlinearity. The proposed identification method is based on the Steiglitz-McBride approach to predict the model parameters. Moreover, a simulation software licensed by the USA Food and Drug Administration that simulates the dynamics of the glucose-insulin system metabolism inside the body, called Type I Diabetes Metabolic Simulator (T1DMS), was used to generate the data. Thirty subjects of different age groups were considered, and the data was generated for a week with a sample per minute, i.e. 302430 data points. This data was then processed using a developed MATLAB code to predict the blood glucose level. Various scenarios were established to validate the proposed approach. The simulations showed very promising results with a very low average root mean square error of 1 mg/dl, which is seven times less compared to other prediction techniques. Other cost functions have also been used and they showed very good results. In the future, this approach can be embedded in closed-loop continuous blood glucose monitoring systems in order to give alerts to the patients and help in calculating the needed insulin dose.

26 July 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
MKMustapha Kamel KHALDI
Mustapha Kamel KHALDI
Mujahed AldhaifallahMujahed Aldhaifallah
Mujahed Aldhaifallah
Ibrahim A. AljamaanIbrahim A. Aljamaan
Ibrahim A. Aljamaan
FAFouad M AL-Sunni
Fouad M AL-Sunni
OTOthman Taha
Othman Taha
DADr. Abdullah Alharbi
Dr. Abdullah Alharbi
Some chemical reactors exhibit coupled dynamics with multiple equilibrium points and strong nonlinearities. The accurate modeling of these dynamics is crucial to optimal control and increasing the reactor’s economic performance. While neural networks can effectively handle complex nonlinearities, they sacrifice interpretability. Alternatively, block-oriented Hammerstein–Wiener models and Koopman operator-based linear predictors combine nonlinear representation with linear dynamics, offering a gray-box identification approach. This paper comprehensively reviews recent advancements in both the Hammerstein–Wiener and Koopman operator methods and benchmarks their accuracy against neural network-based approaches to modeling a large-scale industrial Fluid Catalytic Cracking fractionator. Furthermore, Monte Carlo simulations are employed to validate performance under varying signal-to-noise ratios. The results demonstrate that the Koopman bilinear model significantly outperforms the other methods in terms of accuracy and robustness.

10 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ibrahim A. AljamaanIbrahim A. Aljamaan
Ibrahim A. Aljamaan
AAAhmed Alenany
Ahmed Alenany
Anesthesia refers to the process of preventing pain and relieving stress on the patient’s body during medical operations. Due to its vital importance in health care systems, the automation of anesthesia has gained a lot of interest in the past two decades and, for this purpose, several models of anesthesia are proposed in the literature. In this paper, a Wiener Box-Jenkins model, consisting of linear dynamics followed by a static polynomial nonlinearity and additive colored noise, is used to model anesthesia. A set of input–output data is generated using closed-loop simulations of the Pharmacokinetic–Pharmacodynamic nonlinear (PK/PD) model relating the drug infusion rates, in [μgkg−1min−1], to the Depth of Anesthesia (DoA), in [%]. The model parameters are then estimated offline using particle swarm optimization (PSO) technique. Several Monte Carlo simulations and validation tests are conducted to evaluate the performance of the identified model. The simulation showed very promising results with a quick convergence in less than 10 iterations, with a percentage error less than 1.5%.

2 August 2026 in Results in Engineering
Verified
Journal Article
Open access
MRMohamed M. Refaat
Mohamed M. Refaat
Mujahed AldhaifallahMujahed Aldhaifallah
Mujahed Aldhaifallah
Ibrahim A. AljamaanIbrahim A. Aljamaan
Ibrahim A. Aljamaan
ABAbdullah Bubshait
Abdullah Bubshait


8 December 2025 in Results in Engineering
Verified
Journal Article
Open access
RARahaf F. Alqadda
Rahaf F. Alqadda
FAFatimah B. Alhumaidi
Fatimah B. Alhumaidi
KAKawther H. Alsadah
Kawther H. Alsadah
DADalal D. Alahmari
Dalal D. Alahmari
MHMariam M. Hegazi
Mariam M. Hegazi
Ibrahim A. AljamaanIbrahim A. Aljamaan
Ibrahim A. Aljamaan