Veronika Oravczová

Veronika Oravczová

Auto-generated profile, based on publicly available information

Veronika Oravczová


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MTMarek Tatarko
Marek Tatarko
SSSandro Spagnolo
Sandro Spagnolo
VOVeronika Oravczová
Veronika Oravczová
JSJudit Süle
Judit Süle
MHMilan Hun
Milan Hun
Tibor HianikTibor Hianik
Tibor Hianik
A multiharmonic quartz crystal microbalance (QCM) has been applied to study the viscoelastic properties of the aptamer-based sensing layers at the surface of a QCM transducer covered by neutravidin following interaction with bacteria Listeria innocua. Addition of bacteria in the concentration range 5 × 103–106 CFU/mL resulted in a decrease of resonant frequency and in an increase of dissipation. The frequency decrease has been lower than one would expect considering the dimension of the bacteria. This can be caused by lower penetration depth of the acoustics wave (approximately 120 nm) in comparison with the thickness of the bacterial layer (approximately 500 nm). Addition of E. coli at the surface of neutravidin as well as aptamer layers did not result in significant changes in frequency and dissipation. Using the Kelvin–Voight model the analysis of the viscoelastic properties of the sensing layers was performed and several parameters such as penetration depth, Γ, viscosity coefficient, η, and shear modulus, μ, were determined following various modifications of QCM transducer. The penetration depth decreased following adsorption of the neutravidin layer, which is evidence of the formation of a rigid protein structure. This value did not change significantly following adsorption of aptamers and Listeria innocua. Viscosity coefficient was higher for the neutravidin layer in comparison with the naked QCM transducer in a buffer. However, a further increase of viscosity coefficient took place following attachment of aptamers suggesting their softer structure. The interaction of Listeria innocua with the aptamer layer resulted in slight decrease of viscosity coefficient. The shearing modulus increased for the neutravidin layer and decreased following aptamer adsorption, while a slight increase of µ was observed after the addition of Listeria innocua.

2 November 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
VOVeronika Oravczová
Veronika Oravczová
MTMarek Tatarko
Marek Tatarko
JSJudit Süle
Judit Süle
MHMilan Hun
Milan Hun
ZKZoltán Kerényi
Zoltán Kerényi
Tibor HianikTibor Hianik
Tibor Hianik
Early detection of foodborne pathogens is significant for ensuring food safety. Nowadays, the detection of pathogens found in food can take up to 72 h and it might take a week to confirm a positive sample. While standardized methods give test results in a shorter period, the reoccurring costs for each measurement are high. Therefore, it is necessary to develop technology that will be low-cost, fast, simple and accurate enough. Biosensors in combination with nucleic acid aptamers offer such possibilities. This work is focused on the development and testing of a biosensor based on DNA aptamers for detection of pathogenic bacteria Listeria innocua using the method of multi-harmonic quartz crystal microbalances (QCM). The aptasensor was prepared on the surface of a piezo crystal, whose frequency was affected by deposited mass. An aptamer specific to the genus Listeria spp. was used for the detection of this pathogen, which includes 16 subspecies, out of which 3 are excluded as their antigen structure differs from other species (L. murrayi, L. grayi, L. ivanovii). We found that addition of the pathogens at the surface of QCM transducer modified by aptamers resulted in the decrease of the resonant frequency in concentration depending manner. We also confirmed the specificity of the aptamer used for Listeria innocua, as neglected response of the sensor took place for E. coli for which Listeria spp. has some partial antigens identical and thus can cause cross-reactions in serological tests. The developed aptasensor showed promising sensitivity and specificity for real-time detection of Listeria innocua, with a detection time of 30 min. The achieved limit of detection was approximately 1.6 × 103 CFU/mL.