Flow leakage due to cavitation erosion occurred at the socket welding part downstream of the multi-stage orifice installed in the auxiliary feedwater (AFW) pump recirculation line of the domestic nuclear power plant (NPP). To assess the adequacy of the changed operating flow rate proposed by a domestic NPP operator as the corrective measure concerning the flow leakage in the AFW pump recirculation line, the pattern of the cavitation flow in the eight-stage orifice and the connecting pipe depending on the magnitude of the operating flow rate was predicted by using ANSYS CFX R19.1. Additionally, using ANSYS Mechanical, the structural analysis was conducted under the same operating flow rate condition used for the flow analysis, and the structural integrity was evaluated for the allowable stress. Based on the flow analysis results, it was found that the operating flow rate was the main factor to influence the cavitation behavior inside the multi-stage orifice, and cavitation flow still happened even in the vicinity of the corrected operating flow rate, so it should be necessary to fundamentally review the adequacy of the multi-stage orifice design. On the other hand, the geometric dimensions and arrangement of orifice hole position at the individual stage of the multi-stage orifice may have a significant influence on the characteristics of pressure drop and flow patterns (including cavitation). Therefore, these effects were examined by simulating an analysis model in which the hole diameter of the eighth-stage orifice was changed under the design flow rate condition. As a result of flow analysis, it was found that reducing the hole diameter in the eighth stage orifice resulted in increasing the pressure drop. In relation to the structural integrity of the eight-stage orifice and the connecting pipe, it was found that its integrity could be maintained under the design and operating flow rate conditions.
The Korea Institute of Nuclear Safety (KINS) is tasked with the technical supporting for approving the safety of specific components or design modifications in nuclear power plant. When a licensee submits analysis to the Nuclear Safety & Security Commission (NSSC) for acceptance, KINS staff reviews this analysis and sometimes conducts independent audit calculations. Though recently licensing applications supported by using Computational Fluid Dynamics (CFD) software are increasing for nuclear safety problems, there is no CFD software which obtains a licensing from the domestic regulatory body until now. Additionally, there is no domestic regulatory guideline for the comprehensive evaluation of CFD software. Therefore, from the nuclear regulatory perspective, it is necessary to perform the systematic assessment and prepare the domestic regulatory guideline for checking whether valid CFD software is used for nuclear safety problems. In this paper, regulatory audit calculation activities on the applicability of CFD software to nuclear safety problems was briefly explained.