Background: Extracorporeal membrane oxygenation (ECMO) has expanding indications for cardiopulmonary resuscitation including severe acute respiratory distress syndrome (ARDS). Despite the adjunct of ECMO for patients with severe ARDS, they often have prolonged mechanical ventilation and are subject to many of its inherent complications. Here, we describe patients who were cannulated for venovenous (VV) ECMO and were taken off positive pressure ventilation. Methods: This is a primary analysis of patients admitted at a tertiary medical center between the dates of August 2014 to January 2020 who were cannulated to ECMO for refractory respiratory failure. We included all patients ≥18 years old. Patients who were extubated or had a tracheostomy and taken off positive pressure while on ECMO were classified as “off positive pressure ventilation (PPV)” and were compared to patients who remained “on PPV” while on ECMO. Primary outcome was survival to hospital discharge. Secondary outcomes were ventilator free days at 30 days and 60 days after ECMO cannulation, time from cannulation to date of first out-of-bed (OOB), and hospital length of stay (LOS). Patient characteristics were derived from routine clinical information in the electronic health record (EHR). Categorical characteristics were compared using chi-square test or Fisher exact test. Continuous characteristics were compared using independent samples t-test or Wilcoxon–Mann–Whitney test. p-values were reported from all analysis. Results: Sixty-five patients were included in this retrospective analysis. Forty-eight were managed on ECMO with PPV and 17 patients were removed from PPV. Patients removed from PPV had significantly higher lung injury scores prior to cannulation (2.5 ± 0.6 vs. 1.04 ± 0.3; p = 0.031) and non-significantly longer duration of ventilation prior to ECMO (6.1 days ± 2.1 vs. 5.0 days ± 01.1; p = 0.634). One hundred percent (100%) of patients removed from PPV survived to hospital discharge compared to 45% who received PPV throughout their duration of ECMO management (p < 0.001). The mean ventilator free days at day 60 was 15 with PPV and 36 without PPV (p = 0.003). The average duration from cannulation to mobilization (i.e., out-of-bed) was 18 days with PPV and 7 days without PPV (p = 0.015). Conclusions: Patients taken off PPV while on ECMO had a very high likelihood of survival to discharge and were mobilized in half as many days. While this likely reflects patient selection, the benefit of early mobilization is well documented and the approach of extubating while on ECMO warrants further investigation.
For patients on extracorporeal membrane oxygenation (ECMO) who require renal replacement therapy (RRT), dialysis can be achieved through a dedicated hemodialysis (HD) catheter or direct connection to the ECMO circuit. The relative effect of each on filtration efficacy is not known. We conducted a retrospective single-center analysis of patients on ECMO who required CRRT. We examined the outcomes of blood biomarkers and transmembrane filter pressures, comparing sessions by attachment approach. All analyses were clustered by patient. Of the 33 patients (7 ECMO access and 23 HD catheter access) that met the inclusion criteria, there were a total of 493 CRRT sessions (93 ECMO access and 400 HD catheter access). At the end of the first 12 h of CRRT therapy, the ECMO group had a greater rate of decline in serum BUN than the HD catheter access group (2.5 mg/dl (SD 11) vs. 2 mg/dl (SD 6), p = 0.035). Additionally, the platelet level was significantly higher in the ECMO group compared to the HD catheter access group after 72 h (94.5 k/uL (SD 41) vs. 71 k/uL (SD 29), p = 0.008). Utilizing the ECMO circuit as direct venous access for CRRT was associated with some improved filtration proximal outcomes.
The transition from control modes to spontaneous modes is ubiquitous for mechanically ventilated patients yet there is little data describing the changes and patterns that occur to breathing during this transition for patients on ECMO. We identified high fidelity data among a diverse cohort of 419 mechanically ventilated patients on ECMO. We examined every ventilator change, describing the differences in >30,000 sets of original ventilator observations, focused around the time of transition from control modes to spontaneous modes. We performed multivariate regression with mixed effects, clustered by patient, to examine changes in ventilator characteristics within patients, including a subset among patients with low compliance (<30 milliliters (mL)/centimeters water (cmH2O)). We found that during the transition to spontaneous modes among patients with low compliance, patients exhibited greater tidal volumes (471 mL (364,585) vs. 425 mL (320,527); p < 0.0001), higher respiratory rate (23 breaths per minute (bpm) (18,28) vs. 18 bpm (14,23); p = 0.003), greater mechanical power (elastic component) (0.08 mL/(cmH2O × minute) (0.05,0.12) vs. 0.05 mL/(cmH2O × minute) (0.02,0.09); p < 0.0001) (range 0 to 1.4), and lower positive end expiratory pressure (PEEP) (6 cmH2O (5,8) vs. 10 cmH2O (8,11); p < 0.0001). For patients on control modes, the combination of increased tidal volume and increased respiratory rate was temporally associated with significantly low partial pressure of arterial oxygen (PaO2)/fraction of inspired oxygen (FiO2) ratio (p < 0.0001). These changes in ventilator parameters warrant prospective study, as they may be associated with worsened lung injury.
ICUs are loud and there is an association between ambient sound and worsened sleep quality. In contrast to ambient sound, short acoustic interruptions or sound spikes—for example, brief alarm tones—cause arousal from sleep in healthy patients, but remain understudied in critically ill patients, despite the observed frequency of ICU alarms. We collected greater than 2.3 million values of ambient sound (every second) among 14 patients in the ICU over a median of two nights (interquartile range, 1–2) each. We identified brief acoustic interruptions/sound spikes—increases of greater than or equal to 20 dB above ambient—over 1 second. Patients experienced a median of five interruptions greater than or equal to 20 dB (interquartile range, 2–12) per night. Each interruption was associated with a 1-point decrease in patient reported quality of sleep, as assessed by the Richards Campbell Sleep Questionnaire. Our observations suggest a possible relationship between acoustic interruptions and worsened perceived sleep.
About Me
NRAEMT in Level 1 Trauma Center. Research Assistant.
NRAEMT in Level 1 Trauma Center. Research Assistant.