Vasudevan Lakshminarayanan

Prof. Dr. Vasudevan Lakshminarayanan

Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada
+1
orcid

Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ABAmitojdeep Singh Brar
Amitojdeep Singh Brar
SSSourya Sengupta
Sourya Sengupta
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
Deep learning methods have been very effective for a variety of medical diagnostic tasks and have even outperformed human experts on some of those. However, the black-box nature of the algorithms has restricted their clinical use. Recent explainability studies aim to show the features that influence the decision of a model the most. The majority of literature reviews of this area have focused on taxonomy, ethics, and the need for explanations. A review of the current applications of explainable deep learning for different medical imaging tasks is presented here. The various approaches, challenges for clinical deployment, and the areas requiring further research are discussed here from a practical standpoint of a deep learning researcher designing a system for the clinical end-users.

4 April 2011 in Journal of Modern Optics
Verified
Journal Article
Closed access
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
AFAndre Fleck
Andre Fleck
In this paper we review a special set of orthonormal functions, namely Zernike polynomials which are widely used in representing the aberrations of optical systems. We give the recurrence relations, relationship to other special functions, as well as scaling and other properties of these important polynomials. Mathematica code for certain operations are given in the Appendix.

25 November 2015 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
AAAhmed Almazroa
Ahmed Almazroa
RBRitambhar Burman
Ritambhar Burman
Kaamran RaahemifarKaamran Raahemifar
Kaamran Raahemifar
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed.

1 July 1993 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
RARaymond A. Applegate
Raymond A. Applegate
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
Evidence suggests that the psychophysically determined Stiles–Crawford effect of the first kind (SCE) reflects waveguide properties of human photoreceptors. The peak of the SCE data set is assumed to reflect the principal alignment tendencies, and the spread (e.g., ρ value, the curvature or width at half-height) is assumed to reflect the directionality (i.e., interreceptor differences in alignment) of the population of photoreceptors being tested. As such, disruption of the normal SCE can be used and/or has been used (1) to document early natural history of retinal pathology involving the photoreceptors, (2) to provide a firm rationale for therapeutic intervention, and (3) to provide a method for monitoring therapies designed to alter the natural course of retinal-disease processes. We report large-sample norms for foveal SCE peak location and spread (horizontal peak location, nasal 0.51 ± 0.72, horizontal ρ value 0.047 ± 0.013, vertical peak location, superior 0.20 ± 0.64, vertical ρ value 0.053 ± 0.012), compare these norms with values determined in other laboratories, and discuss the various mathematical forms used for the empirical description of SCE data sets.

6 March 2018
Verified
Conference Paper
Closed access
PDF file
AAAhmed A. Almazroa
Ahmed A. Almazroa
SASami Alodhayb
Sami Alodhayb
EOEssameldin Osman
Essameldin Osman
EREslam Ramadan
Eslam Ramadan
MHMohammed Hummadi
Mohammed Hummadi
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
Glaucoma neuropathy is a major cause of irreversible blindness worldwide. Current models of chronic care will not be able to close the gap of growing prevalence of glaucoma and challenges for access to healthcare services. Teleophthalmology is being developed to close this gap. In order to develop automated techniques for glaucoma detection which can be used in tele-ophthalmology we have developed a large retinal fundus dataset. A de-identified dataset of retinal fundus images for glaucoma analysis (RIGA) was derived from three sources for a total of 750 images. The optic cup and disc boundaries for each image was marked and annotated manually by six experienced ophthalmologists and included the cup to disc (CDR) estimates. Six parameters were extracted and assessed (the disc area and centroid, cup area and centroid, horizontal and vertical cup to disc ratios) among the ophthalmologists. The inter-observer annotations were compared by calculating the standard deviation (SD) for every image between the six ophthalmologists in order to determine if the outliers amongst the six and was used to filter the corresponding images. The data set will be made available to the research community in order to crowd source other analysis from other research groups in order to develop, validate and implement analysis algorithms appropriate for tele-glaucoma assessment. The RIGA dataset can be freely accessed online through University of Michigan, Deep Blue website (doi:10.7302/Z23R0R29).

27 August 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
HKHoda Kheradfallah
Hoda Kheradfallah
ASArya Sarkar
Arya Sarkar
JBJanarthanam Jothi Balaji
Janarthanam Jothi Balaji
Diabetic Retinopathy (DR) is a leading cause of vision loss in the world. In the past few years, artificial intelligence (AI) based approaches have been used to detect and grade DR. Early detection enables appropriate treatment and thus prevents vision loss. For this purpose, both fundus and optical coherence tomography (OCT) images are used to image the retina. Next, Deep-learning (DL)-/machine-learning (ML)-based approaches make it possible to extract features from the images and to detect the presence of DR, grade its severity and segment associated lesions. This review covers the literature dealing with AI approaches to DR such as ML and DL in classification and segmentation that have been published in the open literature within six years (2016–2021). In addition, a comprehensive list of available DR datasets is reported. This list was constructed using both the PICO (P-Patient, I-Intervention, C-Control, O-Outcome) and Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) 2009 search strategies. We summarize a total of 114 published articles which conformed to the scope of the review. In addition, a list of 43 major datasets is presented.