Wojciech Filipiak

Dr. Wojciech Filipiak

Faculty of Pharmacy, Collegium Medicum im. Ludwika Rydygiera in Bydgoszcz University Nicolaus Copernicus in Toruń, Bydgoszcz, Kujawsko-Pomorskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2014 in Journal of Breath Research
Verified
Journal Article
Closed access
BCB de Lacy Costello
B de Lacy Costello
AAA Amann
A Amann
HAHuda Al-Kateb
Huda Al-Kateb
CFC Flynn
C Flynn
Wojciech FilipiakWojciech Filipiak
Wojciech Filipiak
NRN M Ratcliffe
N M Ratcliffe
A compendium of all the volatile organic compounds (VOCs) emanating from the human body (the volatolome) is for the first time reported. 1840 VOCs have been assigned from breath (872), saliva (359), blood (154), milk (256), skin secretions (532) urine (279), and faeces (381) in apparently healthy individuals. Compounds were assigned CAS registry numbers and named according to a common convention where possible. The compounds have been grouped into tables according to their chemical class or functionality to permit easy comparison. Some clear differences are observed, for instance, a lack of esters in urine with a high number in faeces. Careful use of the database is needed. The numbers may not be a true reflection of the actual VOCs present from each bodily excretion. The lack of a compound could be due to the techniques used or reflect the intensity of effort e.g. there are few publications on VOCs from blood compared to a large number on VOCs in breath. The large number of volatiles reported from skin is partly due to the methodologies used, e.g. collecting excretions on glass beads and then heating to desorb VOCs. All compounds have been included as reported (unless there was a clear discrepancy between name and chemical structure), but there may be some mistaken assignations arising from the original publications, particularly for isomers. It is the authors' intention that this database will not only be a useful database of VOCs listed in the literature, but will stimulate further study of VOCs from healthy individuals. Establishing a list of volatiles emanating from healthy individuals and increased understanding of VOC metabolic pathways is an important step for differentiating between diseases using VOCs.

29 September 2009 in BMC Cancer
Verified
Journal Article
Open access
PDF file
ABAmel Bajtarevic
Amel Bajtarevic
CAClemens Ager
Clemens Ager
MPMartin Pienz
Martin Pienz
MKMartin Klieber
Martin Klieber
KSKonrad Schwarz
Konrad Schwarz
AAAnton Amann
Anton Amann
Background: Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive diagnosis of lung cancer would improve prognosis and enlarge treatment options. Analysis of exhaled breath would be an ideal diagnostic method, since it is non-invasive and totally painless. Methods: Exhaled breath and inhaled room air samples were analyzed using proton transfer reaction mass spectrometry (PTR-MS) and solid phase microextraction with subsequent gas chromatography mass spectrometry (SPME-GCMS). For the PTR-MS measurements, 220 lung cancer patients and 441 healthy volunteers were recruited. For the GCMS measurements, we collected samples from 65 lung cancer patients and 31 healthy volunteers. Lung cancer patients were in different disease stages and under treatment with different regimes. Mixed expiratory and indoor air samples were collected in Tedlar bags, and either analyzed directly by PTR-MS or transferred to glass vials and analyzed by gas chromatography mass spectrometry (GCMS). Only those measurements of compounds were considered, which showed at least a 15% higher concentration in exhaled breath than in indoor air. Compounds related to smoking behavior such as acetonitrile and benzene were not used to differentiate between lung cancer patients and healthy volunteers. Results: Isoprene, acetone and methanol are compounds appearing in everybody's exhaled breath. These three main compounds of exhaled breath show slightly lower concentrations in lung cancer patients as compared to healthy volunteers (p < 0.01 for isoprene and acetone, p = 0.011 for methanol; PTR-MS measurements). A comparison of the GCMS-results of 65 lung cancer patients with those of 31 healthy volunteers revealed differences in concentration for more than 50 compounds. Sensitivity for detection of lung cancer patients based on presence of (one of) 4 different compounds not arising in exhaled breath of healthy volunteers was 52% with a specificity of 100%. Using 15 (or 21) different compounds for distinction, sensitivity was 71% (80%) with a specificity of 100%. Potential marker compounds are alcohols, aldehydes, ketones and hydrocarbons. Conclusion: GCMS-SPME is a relatively insensitive method. Hence compounds not appearing in exhaled breath of healthy volunteers may be below the limit of detection (LOD). PTR-MS, on the other hand, does not need preconcentration and gives much more reliable quantitative results then GCMS-SPME. The shortcoming of PTR-MS is that it cannot identify compounds with certainty. Hence SPME-GCMS and PTR-MS complement each other, each method having its particular advantages and disadvantages. Exhaled breath analysis is promising to become a future non-invasive lung cancer screening method. In order to proceed towards this goal, precise identification of compounds observed in exhaled breath of lung cancer patients is necessary. Comparison with compounds released from lung cancer cell cultures, and additional information on exhaled breath composition in other cancer forms will be important.

20 June 2012 in BMC Microbiology
Verified
Journal Article
Open access
PDF file
Wojciech FilipiakWojciech Filipiak
Wojciech Filipiak
ASAndreas Sponring
Andreas Sponring
MBMaria Magdalena Baur
Maria Magdalena Baur
AFAnna Filipiak
Anna Filipiak
CAClemens Ager
Clemens Ager
AAAnton Amann
Anton Amann
Background: The routinely used microbiological diagnosis of ventilator associated pneumonia (VAP) is time consuming and often requires invasive methods for collection of human specimens (e.g. bronchoscopy). Therefore, it is of utmost interest to develop a non-invasive method for the early detection of bacterial infection in ventilated patients, preferably allowing the identification of the specific pathogens. The present work is an attempt to identify pathogen-derived volatile biomarkers in breath that can be used for early and non- invasive diagnosis of ventilator associated pneumonia (VAP). For this purpose, in vitro experiments with bacteria most frequently found in VAP patients, i.e. Staphylococcus aureus and Pseudomonas aeruginosa, were performed to investigate the release or consumption of volatile organic compounds (VOCs). Results: Headspace samples were collected and preconcentrated on multibed sorption tubes at different time points and subsequently analyzed with gas chromatography mass spectrometry (GC-MS). As many as 32 and 37 volatile metabolites were released by S. aureus and P. aeruginosa, respectively. Distinct differences in the bacteria-specific VOC profiles were found, especially with regard to aldehydes (e.g. acetaldehyde, 3-methylbutanal), which were taken up only by P. aeruginosa but released by S. aureus. Differences in concentration profiles were also found for acids (e.g. isovaleric acid), ketones (e.g. acetoin, 2-nonanone), hydrocarbons (e.g. 2-butene, 1,10-undecadiene), alcohols (e.g. 2-methyl-1-propanol, 2-butanol), esters (e.g. ethyl formate, methyl 2-methylbutyrate), volatile sulfur compounds (VSCs, e.g. dimethylsulfide) and volatile nitrogen compounds (VNCs, e.g. 3-methylpyrrole). Importantly, a significant VOC release was found already 1.5 hours after culture start, corresponding to cell numbers of ~8*106 [CFUs/ml]. Conclusions: The results obtained provide strong evidence that the detection and perhaps even identification of bacteria could be achieved by determination of characteristic volatile metabolites, supporting the clinical use of breath-gas analysis as non-invasive method for early detection of bacterial lung infections.

1 January 2010 in Cancer Epidemiology, Biomarkers & Prevention
Verified
Journal Article
Closed access
PDF file
Wojciech FilipiakWojciech Filipiak
Wojciech Filipiak
ASAndreas Sponring
Andreas Sponring
AFAnna Filipiak
Anna Filipiak
CAClemens Ager
Clemens Ager
JSJochen Schubert
Jochen Schubert
Jakob TroppmairJakob Troppmair
Jakob Troppmair
The aim of this study was to confirm the existence of volatile organic compounds (VOC) specifically released or consumed by the lung cancer cell line A549, which could be used in future screens as biomarkers for the early detection of lung cancer. For comparison, primary human bronchial epithelial cells (HBEpC) and human fibroblasts (hFB) were included. VOCs were detected in the headspace of cell cultures or medium controls following adsorption on solid sorbents, thermodesorption, and analysis by gas chromatography mass spectrometry. Using this approach, we identified VOCs that behaved similarly in normal and transformed cells. Thus, concentrations of 2-pentanone and 2,4-dimethyl-1-heptene were found to increase in the headspace of A549, HBEpC, and hFB cell cultures. In addition, the ethers methyl tert-butyl ether and ethyl tert-butyl ether could be detected at elevated levels in the case of A549 cells and one of the untransformed cell lines. However, especially branched hydrocarbons and alcohols were seen increased more frequently in untransformed than A549 cells. A big variety of predominantly aldehydes and the ester n-butyl acetate were found at decreased concentrations in the headspace of all cell lines tested compared with medium controls. Again, more different aldehydes were found to be decreased in hFB and HBEpC cells compared with A549 cells and 2-butenal was metabolized exclusively by both control cell lines. These data suggest that certain groups of VOCs may be preferentially associated with the transformed phenotype. Cancer Epidemiol Biomarkers Prev; 19(1); 182–95

29 August 2012 in Journal of Breath Research
Verified
Journal Article
Closed access
Wojciech FilipiakWojciech Filipiak
Wojciech Filipiak
VRV Ruzsanyi
V Ruzsanyi
PMPaweł Mochalski
Paweł Mochalski
AFA Filipiak
A Filipiak
ABA Bajtarevic
A Bajtarevic
AAAnton Amann
Anton Amann
Non-invasive disease monitoring on the basis of volatile breath markers is a very attractive but challenging task. Several hundreds of compounds have been detected in exhaled air using modern analytical techniques (e.g. proton-transfer reaction mass spectrometry, gas chromatography-mass spectrometry) and have even been linked to various diseases. However,the biochemical background for most of compounds detected in breath samples has not been elucidated; therefore, the obtained results should be interpreted with care to avoid false correlations. The major aim of this study was to assess the effects of smoking on the composition of exhaled breath. Additionally, the potential origin of breath volatile organic compounds (VOCs) is discussed focusing on diet, environmental exposure and biological pathways based on other's studies. Profiles of VOCs detected in exhaled breath and inspired air samples of 115 subjects with addition of urine headspace derived from 50 volunteers are presented. Samples were analyzed with GC-MS after preconcentration on multibed sorption tubes in case of breath samples and solid phase micro-extraction (SPME) in the case of urine samples. Altogether 266 compounds were found in exhaled breath of at least 10% of the volunteers. From these, 162 compounds were identified by spectral library match and retention time (based on reference standards). It is shown that the composition of exhaled breath is considerably influenced by exposure to pollution and indoor-air contaminants and particularly by smoking. More than 80 organic compounds were found to be significantly related to smoking, the largest group comprising unsaturated hydrocarbons (29 dienes, 27 alkenes and 3 alkynes). On the basis of the presented results, we suggest that for the future understanding of breath data it will be necessary to carefully investigate the potential biological origin of volatiles, e.g., by means of analysis of tissues, isolated cell lines or other body fluids. In particular, VOCs linked to smoking habit or being the results of human exposure should be considered with care for clinical diagnosis since small changes in their concentration profiles(typically in the ppt(v)–ppb(v) range) revealing that the outbreak of certain disease might be hampered by already high background.

24 November 2008 in Cancer Cell International
Verified
Journal Article
Open access
PDF file
Wojciech FilipiakWojciech Filipiak
Wojciech Filipiak
ASAndreas Sponring
Andreas Sponring
TMTomas Mikoviny
Tomas Mikoviny
CAClemens Ager
Clemens Ager
JSJochen Schubert
Jochen Schubert
Jakob TroppmairJakob Troppmair
Jakob Troppmair
Background: The aim of this work was to confirm the existence of volatile organic compounds (VOCs) specifically released or consumed by lung cancer cells. Methods: 50 million cells of the human non-small cell lung cancer (NSCLC) cell line CALU-1 were incubated in a sealed fermenter for 4 h or over night (18 hours). Then air samples from the headspace of the culture vessel were collected and preconcentrated by adsorption on solid sorbents with subsequent thermodesorption and analysis by means of gas chromatography mass spectrometry (GC-MS). Identification of altogether 60 compounds in GCMS measurement was done not only by spectral library match, but also by determination of retention times established with calibration mixtures of the respective pure compounds. Results: The results showed a significant increase in the concentrations of 2,3,3-trimethylpentane, 2,3,5-trimethylhexane, 2,4-dimethylheptane and 4-methyloctane in the headspace of CALU-1 cell culture as compared to medium controls after 18 h. Decreased concentrations after 18 h of incubation were found for acetaldehyde, 3-methylbutanal, butyl acetate, acetonitrile, acrolein, methacrolein, 2-methylpropanal, 2-butanone, 2-methoxy-2-methylpropane, 2-ethoxy-2-methylpropane, and hexanal. Conclusion: Our findings demonstrate that certain volatile compounds can be cancer-cell derived and thus indicative of the presence of a tumor, whereas other compounds are not released but seem to be consumed by CALU-1 cells.