Jose Ramón Lillo-Beviá

Dr. Jose Ramón Lillo-Beviá

University of Alicante, Alicante, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
Purpose: To validate the new drive indoor trainer Hammer designed by Cycleops®. Methods: A total of 11 cyclists performed 44 randomized and counterbalanced graded exercise tests (100–500 W) at 70-, 85-, and 100-rpm cadences in seated and standing positions on 3 different Hammer units, while a scientific SRM system continuously recorded cadence and power output data. Results: No significant differences were detected between the 3 Hammer devices and the SRM for any workload, cadence, or pedaling condition (P value between 1.00 and .350), except for some minor differences (P = .03 and .04) found in the Hammer 1 at low workloads and for Hammer 2 and 3 at high workloads, all in seated position. Strong intraclass correlation coefficients were found between the power output values recorded by the Hammers and the SRM (≥.996; P = .001), independently from the cadence condition and seated position. Bland–Altman analysis revealed low bias (−5.5 to 3.8) and low SD of bias (2.5–5.3) for all testing conditions, except marginal values found for the Hammer 1 at high cadences and seated position (9.6 [6.6]). High absolute reliability values were detected for the 3 Hammers (150–500 W; coefficient of variation <1.2%; SEM <2.1). Conclusions: This new Cycleops trainer is a valid and reliable device to drive and measure power output in cyclists, providing an alternative to larger and more expensive laboratory ergometers and allowing cyclists to use their own bicycles.

7 November 2019 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá
Javier Courel-IbáñezJavier Courel-Ibáñez
Javier Courel-Ibáñez
VCVictor Cerezuela-Espejo
Victor Cerezuela-Espejo
RMRicardo Morán-Navarro
Ricardo Morán-Navarro
AMAlejandro Martínez-Cava
Alejandro Martínez-Cava
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
Lillo-Beviá, JR, Courel-Ibáñez, J, Cerezuela-Espejo, V, Morán-Navarro, R, Martínez-Cava, A, and Pallarés, JG. Is the functional threshold power a valid metric to estimate the maximal lactate steady state in cyclists? J Strength Cond Res 36(1): 167–173, 2022—The aims of this study were to determine (a) the repeatability of a 20-minute time-trial (TT20), (b) the location of the TT20 in relation to the main physiological events of the aerobic-anaerobic transition, and (c) the predictive power of a list of correction factors and linear/multiple regression analysis applied to the TT20 result to estimate the individual maximal lactate steady state (MLSS). Under laboratory conditions, 11 trained male cyclists and triathletes (V̇ o 2 max 59.7 ± 3.0 ml·kg −1 ·min −1 ) completed a maximal graded exercise test to record the power output associated with the first and second ventilatory thresholds and V̇ o 2 max measured by indirect calorimetry, several 30 minutes constant tests to determine the MLSS, and 2 TT20 tests with a short warm-up. Very high repeatability of TT20 tests was confirmed (standard error of measurement of ±3 W and smallest detectable change of ±9 W). Validity results revealed that MLSS differed substantially from TT20 (bias = 26 ± 7 W). The maximal lactate steady state was then estimated from the traditional 95% factor (bias = 12 ± 7 W) and a novel individual correction factor (ICF% = MLSS/TT20), resulting in 91% (bias = 1 ± 6 W). Complementary linear (MLSS = 0.7488 × TT20 + 43.24; bias = 0 ± 5 W) and multiple regression analysis (bias = 0 ± 4 W) substantially improved the individual MLSS workload estimation. These findings suggest reconsidering the TT20 procedures and calculations to increase the effectiveness of the MLSS prediction.

1 July 2020 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá
Ricardo Morán-NavarroRicardo Morán-Navarro
Ricardo Morán-Navarro
VCVictor Cerezuela-Espejo
Victor Cerezuela-Espejo
RMRicardo Mora-Rodriguez
Ricardo Mora-Rodriguez
Three to 5 cycling tests to exhaustion allow prediction of time to exhaustion (TTE) at power output based on calculation of critical power (CP). We aimed to determine the accuracy of CP predictions of TTE at power outputs habitually endured by cyclists. Fourteen endurance-trained male cyclists underwent 4 randomized cycle-ergometer TTE tests at power outputs eliciting (i) mean Wingate anaerobic test (WAnTmean), (ii) maximal oxygen consumption, (iii) respiratory compensation threshold (VT2), and (iv) maximal lactate steady state (MLSS). Tests were conducted in duplicate with coefficient of variation of 5%–9%. Power outputs were 710 ± 63 W for WAnTmean, 366 ± 26 W for maximal oxygen consumption, 302 ± 31 W for VT2 and 247 ± 20 W for MLSS. Corresponding TTE were 00:29 ± 00:06, 03:23 ± 00:45, 11:29 ± 05:07, and 76:05 ± 13:53 min:s, respectively. Power output associated with CP was only 2% lower than MLSS (242 ± 19 vs. 247 ± 20 W; P < 0.001). The CP predictions overestimated TTE at WAnTmean (00:24 ± 00:10 mm:ss) and MLSS (04:41 ± 11:47 min:s), underestimated TTE at VT2 (–04:18 ± 03:20 mm:ss; P < 0.05), and correctly predicted TTE at maximal oxygen consumption. In summary, CP accurately predicts MLSS power output and TTE at maximal oxygen consumption. However, it should not be used to estimate time to exhaustion in trained cyclists at higher or lower power outputs (e.g., sprints and 40-km time trials). Novelty CP calculation enables to predict TTE at any cycling power output. We tested those predictions against measured TTE in a wide range of cycling power outputs. CP appropriately predicted TTE at maximal oxygen consumption intensity but err at higher and lower cycling power outputs.

15 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VRVíctor Rodríguez-Rielves
Víctor Rodríguez-Rielves
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá
ÁBÁngel Buendía-Romero
Ángel Buendía-Romero
ACAlejandro Martínez Cava
Alejandro Martínez Cava
AHAlejandro Hernández-Belmonte
Alejandro Hernández-Belmonte
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
This study aimed to examine the validity and reliability of the recently developed Assioma Favero pedals under laboratory cycling conditions. In total, 12 well-trained male cyclists and triathletes (VO2max = 65.7 ± 8.7 mL·kg−1·min−1) completed five cycling tests including graded exercises tests (GXT) at different cadences (70–100 revolutions per minute, rpm), workloads (100–650 Watts, W), pedaling positions (seated and standing), vibration stress (20–40 Hz), and an 8-s maximal sprint. Tests were completed using a calibrated direct drive indoor trainer for the standing, seated, and vibration GXTs, and a friction belt cycle ergometer for the high-workload step protocol. Power output (PO) and cadence were collected from three different brand, new pedal units against the gold-standard SRM crankset. The three units of the Assioma Favero exhibited very high within-test reliability and an extremely high agreement between 100 and 250 W, compared to the gold standard (Standard Error of Measurement, SEM from 2.3–6.4 W). Greater PO produced a significant underestimating trend (p < 0.05, Effect size, ES ≥ 0.22), with pedals showing systematically lower PO than SRM (1–3%) but producing low bias for all GXT tests and conditions (1.5–7.4 W). Furthermore, vibrations ≥ 30 Hz significantly increased the differences up to 4% (p < 0.05, ES ≥ 0.24), whereas peak and mean PO differed importantly between devices during the sprints (p < 0.03, ES ≥ 0.39). These results demonstrate that the Assioma Favero power meter pedals provide trustworthy PO readings from 100 to 650 W, in either seated or standing positions, with vibrations between 20 and 40 Hz at cadences of 70, 85, and 100 rpm, or even at a free chosen cadence.

1 June 2018
Verified
Journal Article
Closed access
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá

1 January 2022 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
PDF file
VRVíctor Rodríguez-Rielves
Víctor Rodríguez-Rielves
AMAlejandro Martínez-Cava
Alejandro Martínez-Cava
ÁBÁngel Buendía-Romero
Ángel Buendía-Romero
JLJose Ramón Lillo-Beviá
Jose Ramón Lillo-Beviá
Javier Courel-IbáñezJavier Courel-Ibáñez
Javier Courel-Ibáñez
Jesus Garcia-PallaresJesus Garcia-Pallares
Jesus Garcia-Pallares
Purpose: To examine the reproducibility (intradevice and interdevice agreement) of the Rotor 2INpower device under a wide range of cycling conditions. Methods: Twelve highly trained male cyclists and triathletes completed 5 cycling tests, including graded exercise tests at different cadences (70–100 rpm), workloads (100–650 W), pedaling positions (seated and standing), and vibration conditions (20–40 Hz) and an 8-second maximal sprint (>1000 W). An intradevice analysis included a comparison between the power output registered by 3 units of Rotor 2INpower, whereas the power output provided by each one of these units and the gold-standard SRM crankset were compared for the interdevice analysis. Among others, statistical calculations included the standard error of measurement, expressed in absolute (in watts) and relative terms as the coefficient of variation (CV). Results: Except for the graded exercise test seated at 100 rpm/100 W (CV = 10.2%), the intradevice analysis showed an acceptable magnitude of error (CV ≤ 6.9%, standard error of measurement ≤ 12.3 W) between the 3 Rotor 2INpower. Similarly, these 3 units showed an acceptable agreement with the gold standard in all graded exercise test situations (CV ≤ 4.0%, standard error of measurement ≤ 13.1 W). On the other hand, both the intradevice and interdevice agreements proved to be slightly reduced under high cadences (intradevice: CV ≤ 10.2%; interdevice: CV ≤ 4.0%) and vibration (intradevice: CV ≤ 4.0%; interdevice: CV ≤ 3.6%), as well as during standing pedaling (intradevice: CV ≤ 4.1%; interdevice: CV ≤ 2.5%). Although within the limits of an acceptable agreement, measurement errors increased during the sprint tests (CV ≤ 7.4%). Conclusions: Based on these results, the Rotor 2INpower could be considered a reproducible tool to monitor power output in most cycling situations.