Francesco Magoga

Mr. Francesco Magoga

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2024 in La radiologia medica
Verified
Journal Article
Open access
PDF file
SRStefania Rizzo
Stefania Rizzo
LBLuca Bellesi
Luca Bellesi
ADAndrea D’eRmo
Andrea D’eRmo
LBLuca Bonomo
Luca Bonomo
ODOriana D'Ecclesiis
Oriana D'Ecclesiis
FGFilippo Del Grande
Filippo Del Grande
Purposes: The primary objective of this retrospective study was to assess whether the CT dose delivered to oncologic patients was different in a subspecialty radiology department, compared to a general radiology department. The secondary explorative objective was to assess whether the objective image quality of CT examinations was different in the two settings. Materials and methods: Chest and abdomen CT scans performed for oncologic indications were selected from a general radiology department and a subspecialty radiology department. By using a radiation dose management platform, we extracted and compared CT dose index (CTDIvol) and dose length product (DLP) both for each phase and for the entire CT exams. For objective image quality evaluation, we calculated the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) at the level of the liver and of the aorta. A P-value < 0.05 was considered significant. Results: A total of 7098 CT examinations were included. CTDIvol was evaluated in 12,804 phases; DLP in 10,713 phases and in 6714 examinations. The CTDIvol and DLP overall were significantly lower in the subspecialty radiology department compared to the general radiology department CTDI median (IQR) 5.19 (3.91–7.00) and 5.51 (4.17–7.72), DLP median and IQR of 490.0 (342.4–710.6) and 503.4 (359.9–728.8), p < 0.001 and p = 0.01, respectively. The objective image quality showed no significant difference in the general and subspecialty radiology departments, with median and IQR of 4.03 (2.82–5.51) and 3.84 (3.09–4.94) for SNRLiv (p = 0.58); 4.81 (2.70–7.62) and 4.34 (3.05–6.25) for SNRAo (p = 0.30); 0.83 (0.20–1.89) and 1.00 (0.35–1.57) for CNRLiv (p = 0.99); 2.23 (0.09–3.83) and 1.01 (0.15–2.84) for CNRAo (p = 0.24) with SNRLiv (p = 0.58), SNRAo (p = 0.30), CNRLiv (p = 0.99) and CNRAo (p = 0.24). Conclusion: In a subspecialty radiology department, CT protocols are optimized compared to a general radiology department leading to lower doses to oncologic patients without significant objective image quality degradation.

5 March 2022 in La radiologia medica
Verified
Journal Article
Open access
PDF file
SRStefania Rizzo
Stefania Rizzo
CCCarola Catanese
Carola Catanese
CPCarla Puligheddu
Carla Puligheddu
SESamantha Epistolio
Samantha Epistolio
GRGiulia Ramelli
Giulia Ramelli
LCLuca Ceriani
Luca Ceriani
Purpose: The main objective of this study was to assess the presence of pulmonary infiltrates with computed tomography (CT) appearance compatible with infection by coronavirus disease 2019 (COVID-19), in Canton Ticino in the 2 months preceding the first official case. Secondary aims were to compare the classification of infiltrates in the same time frame in 2020 and 2019; to compare the number of chest CT scans in the same period; to search for pathological confirmation of the virus. Materials and methods: Chest CT scans performed between January 1 and February 24 in 2019 and 2020 were collected and classified by COVID-19 Reporting and Data System (CO-RADS). Pathological presence of the virus was searched for when appropriate material was available. Results: The final cohort included 881 patients. Among the CO-RADS 3 and 4 categories, 30 patients had pneumonitis of unknown etiology. Pathological specimens were available in six patients but they were negative for COVID-19. Conclusion: Before the first official case of COVID-19 infection, in Canton Ticino there were about 30 cases of pneumonitis of uncertain origin, with CT appearance compatible with infection by COVID-19, but with no confirmation of the disease. The number of chest CT scans in the first two months of 2020 was > 12% compared to 2019.

29 May 2025 in Cancers
Verified
Journal Article
Open access
PDF file
SRStefania Rizzo
Stefania Rizzo
LBLuca Bellesi
Luca Bellesi
EKEbticem Ben Khalifa
Ebticem Ben Khalifa
SPStefano Presilla
Stefano Presilla
ADAndrea D’ermo
Andrea D’ermo
FGFilippo Del Grande
Filippo Del Grande
Background/Objectives: The primary aim of this study was to evaluate whether the replacement of roughly one-decade-old computed tomography (CT) scanners with new-model CT scanners were associated with an additional reduction in the radiation dose delivered to oncological patients, in a radiological setting where the optimization of protocols had already reached very low radiation doses. An exploratory secondary objective was to evaluate the potential differences in the objective image quality between the CT scans obtained before and after the installation of the new-generation CT scanners. Methods: Chest and abdominal CT examinations conducted for oncologic purposes were retrospectively selected from two time periods—prior to scanner replacement (2022) and following an upgrade (2024)—after five CT systems in our radiology department were replaced. We extracted and compared the CT dose index (CTDI) and dose length product (DLP) for each CT phase. For the objective image quality evaluation, we calculated the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) at the center of the liver and the aorta. An appropriate statistical analysis was performed and a p-value < 0.05 was considered significant. Results: We included 14,601 CT acquisitions, of which 9013 (61.7%) were performed before and 5588 (38.3%) after the replacement of the CT scanners. There were significantly lower values for the CTDI and DLP with the new CT scanners compared to the old ones. The CTDI with the new CT scanners was significantly lower in all phases (p-value = 0.002 for unenhanced phase, and p < 0.001 for arterial, portal venous, and delayed phases). The DLP using the new CT scanners was significantly lower in the arterial, portal venous, and delayed phases (p < 0.001), and it was not significantly different in the unenhanced phase (p = 0.36). There was no significant difference in the SNR at the liver level (p = 0.72) or at the aorta level (p = 0.51). There was no significant difference in the CNR at the liver level (p = 0.24), whereas the CNR was higher with the new CT scanners at the aorta level (p = 0.03). Conclusions: The transition to new-model CT scanners resulted in a significant reduction in the radiation dose delivered by chest and abdomen CT scans, without compromising the objective image quality.

16 April 2025 in Tomography
Verified
Journal Article
Open access
PDF file
Fabio MattiussiFabio Mattiussi
Fabio Mattiussi
Francesco MagogaFrancesco Magoga
Francesco Magoga
SSSimone Schiaffino
Simone Schiaffino
VFVittorio Ferrari
Vittorio Ferrari
ERErmidio Mike Rezzonico
Ermidio Mike Rezzonico
SRStefania Rizzo
Stefania Rizzo
Background/Objectives: Reviewing the entire history of imaging exams of a single patient’s records is an essential step in clinical practice, but it is time and resource consuming, with potential negative effects on workflow and on the quality of medical decisions. The main objective of this study was to evaluate the applicability of three open-source large language models (LLMs) for the automatic generation of concise summaries of patient’s imaging records. Secondary objectives were to assess correlations among the LLMs and to evaluate the length reduction provided by each model. Methods: Three state-of-the-art open-source large language models were selected: Llama 3.2 11B, Mistral 7B, and Falcon 7B. Each model was given a set of radiology reports. The summaries produced by the models were evaluated by two experienced radiologists and one experienced clinical physician using standardized metrics. Results: A variable number of radiological reports (n = 12–56) from four patients were selected and evaluated. The summaries generated by the three LLM showed a good level of accuracy compared with the information contained in the original reports, with positive ratings on both clinical relevance and ease of reference. According to the experts’ evaluations, the use of the summaries generated by LLMs could help to reduce the time spent on reviewing the previous imaging examinations performed, preserving the quality of clinical data. Conclusions: Our results suggest that LLMs are able to generate summaries of the imaging history of patients, and these summaries could improve radiology workflow making it easier to manage large volumes of reports.

19 September 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Fabio MattiussiFabio Mattiussi
Fabio Mattiussi
Francesco MagogaFrancesco Magoga
Francesco Magoga
ACAndrea Cozzi
Andrea Cozzi
SFSalvatore Ferraro
Salvatore Ferraro
GCGabrio Cadei
Gabrio Cadei
SRStefania Rizzo
Stefania Rizzo
Background: ErisNet, a novel AI model to reduce noise in Computed Tomography images. Methods: We trained ErisNet on 23 post-mortem whole-body CT scans. We assessed the objective performance with mean square error (MSE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM) measure, visual information fidelity (VIF), edge preservation index (EPI) and noise variance (NV). We assessed the qualitative performance by six radiologists. To support the visual assessment, we placed circular regions of interest (ROI) in the vitreous body, brain, liver and spleen parenchyma and paravertebral muscle. Results: ErisNet achieved MSE 64.07 ± 46.81, PSNR 31.32 ± 3.69 dB, SSIM 0.93 ± 0.06, VIF 0.49 ± 0.09, EPI 0.97 ± 0.01 and NV 64.69 ± 46.80. The ROI analysis showed a reduction in noise: the SD of the HU decreased by 8% in the vitreous body (from 17.6 to 16.2 HU), by 18% in the brain parenchyma (from 18.85 to 15.40 HU) and by 15–19% in the liver, spleen and paravertebral muscle. The six radiologists confirmed these results by assigning high scores (scale from one to five): overall quality 4.5 ± 0.6, noise suppression/detail preservation 4.7 ± 0.5 and diagnostic confidence 4.8 ± 0.4 (p < 0.01). Conclusions: ErisNet improves the quality of CT images and shows strong potential for processing low-dose scans.