Wookyoung Jang

Mr. Wookyoung Jang

Korea University in korea
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SMSeok Joon Mun
Seok Joon Mun
Wookyoung JangWookyoung Jang
Wookyoung Jang
HPHyun-Seung Park
Hyun-Seung Park
YLYong Jun Lim
Yong Jun Lim
TYTae-Jin Yang
Tae-Jin Yang
KBKi Wan Bong
Ki Wan Bong

15 December 2022 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
Wookyoung JangWookyoung Jang
Wookyoung Jang
SMSeok Joon Mun
Seok Joon Mun
SKSoung-Yon Kim
Soung-Yon Kim
KBKi Wan Bong
Ki Wan Bong

5 June 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Wookyoung JangWookyoung Jang
Wookyoung Jang
ESE Loomee Song
E Loomee Song
SMSeok Joon Mun
Seok Joon Mun
KBKi Wan Bong
Ki Wan Bong

20 July 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
Wookyoung JangWookyoung Jang
Wookyoung Jang
JKJiwoo Kim
Jiwoo Kim
SMSeok Joon Mun
Seok Joon Mun
SKSun Min Kim
Sun Min Kim
KBKi Wan Bong
Ki Wan Bong
Encoded hydrogel microparticles mounting DNA probes are powerful tools for high-performance microRNA (miRNA) detection in terms of sensitivity, specificity, and multiplex detection capability. However, several particle rinsing steps in the assay procedure present challenges for rapid and efficient detection. To overcome this limitation, we encapsulated dense magnetic nanoparticles to reduce the rinsing steps and duration via magnetic separation. A large number of magnetic nanoparticles were encapsulated into hydrogel microparticles based on a discontinuous dewetting technique combined with degassed micromolding lithography. In addition, we attached DNA probes targeting three types of miRNAs related to preeclampsia to magnetically encoded hydrogel microparticles by post-synthesis conjugation and achieved sensitivity comparable to that of conventional nonmagnetic encoded hydrogel microparticles. To demonstrate the multiplex capability of magnetically encoded hydrogel microparticles while maintaining the advantages of the simplified rinsing process when addressing multiple samples, we conducted a triplex detection of preeclampsia-related miRNAs. In conclusion, the introduction of magnetically encoded hydrogel microparticles not only allowed efficient miRNA detection but also provided comparable sensitivity and multiplexed detectability to conventional nonmagnetic encoded hydrogel microparticles.

5 April 2022 in Journal of Polymer Science
Verified
Journal Article
Open access
Wookyoung JangWookyoung Jang
Wookyoung Jang
DKDo Yeon Kim
Do Yeon Kim
SMSeok Joon Mun
Seok Joon Mun
JCJun Hee Choi
Jun Hee Choi
YRYoon Ho Roh
Yoon Ho Roh
KBKi Wan Bong
Ki Wan Bong
Polyethylene glycol (PEG) hydrogel microparticles generated via stop‐flow lithography can be utilized for efficient microparticle‐based cell culture processes because of their high biocompatibility, the molecular diffusion capability in the gel structure, and the tunability of their shape and size. However, the typical functionalization process of PEG microparticles with cell‐adhesion promoters has inevitable limitations, requiring additional linker molecules and the preconjugation of linkers to cell‐adhesion promoters and microparticles. In this study, a simple and direct cell‐adhesion promoter functionalization process of the PEG microparticles is presented by use of aza‐Michael reaction between remnant unreacted acrylate groups in particles and amine groups in cell‐adhesion promoters. On the basis of proposed process, particles are directly conjugated with poly‐l‐lysine (PLL), a typical cell‐adhesion promoter that can electrostatically interact with cellular membranes, in a controllable manner. We demonstrate enhanced cell‐adhesion capabilities of the particles along with the increased amount of conjugated PLL in the particles. Furthermore, to validate extended applicability, the particles are directly conjugated with Gly‐Arg‐Gly‐Asp‐Ser (GRGDS) peptides, in which RGD sequence is involved in the cell‐adhesion behavior of extracellular matrix proteins, including fibronectin. The introduced GRGDS peptides increase the cell‐adhesion capacity of the microparticles binding to integrin proteins in cellular membranes.

12 June 2025 in Small
Verified
Journal Article
Open access
Wookyoung JangWookyoung Jang
Wookyoung Jang
JBJi Won Byun
Ji Won Byun
JCJun Hee Choi
Jun Hee Choi
BKBolam Kim
Bolam Kim
KBKi Wan Bong
Ki Wan Bong
Graphically encoded hydrogel microparticle‐based biosensing is a promising suspension microarray platform by virtue of multiplexing capability, robust sensitivity, and facilitated downstream analysis. However, the absence of a long‐term and stable storage protocol for the hydrogel microparticle has been a bottleneck for the sensing platform to be adapted to practical fields. In this study, the polyethylene glycol (PEG) nanofiller‐mediated lyophilization strategy of the hydrogel microparticles is presented. To inhibit the lyophilization‐induced deformation of the porous structure and geometries of the particles, PEG is utilized as the filler material occupying the porous region in the hydrogel particles to prevent the interaction between polymer chains and the collapse of the porous structure. Based on the filler effect, the high decoding accuracy (more than 95%) for the lyophilized microparticles after reconstitution can be achieved by outstanding preservation of the particle geometries. Furthermore, the immunoassay performance of the antibody‐functionalized microparticles lyophilized with PEG nanofiller is comparable to that of the non‐lyophilized particles. Finally, the possibility of long‐term storage (more than 6 months) of the lyophilized microparticles is confirmed by thermal aging. This finding is expected to promote the hydrogel microparticle‐based sensing platform to be extended to practical fields via the innovation of the storage protocol.