Lluís Freixas

Mr. Lluís Freixas

CIEMAT
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in The Astrophysical Journal
Verified
Journal Article
Open access
HAH. Abe
H. Abe
KAK. Abe
K. Abe
SAS. Abe
S. Abe
AAA. Aguasca-Cabot
A. Aguasca-Cabot
IAIván Agudo
Iván Agudo
JWJ. Watson
J. Watson
The Cherenkov Telescope Array (CTA) is a next-generation ground-based observatory for gamma-ray astronomy at very high energies. The Large-Sized Telescope prototype (LST-1) is located at the CTA-North site, on the Canary Island of La Palma. LSTs are designed to provide optimal performance in the lowest part of the energy range covered by CTA, down to ≃20 GeV. LST-1 started performing astronomical observations in 2019 November, during its commissioning phase, and it has been taking data ever since. We present the first LST-1 observations of the Crab Nebula, the standard candle of very-high-energy gamma-ray astronomy, and use them, together with simulations, to assess the performance of the telescope. LST-1 has reached the expected performance during its commissioning period—only a minor adjustment of the preexisting simulations was needed to match the telescope’s behavior. The energy threshold at trigger level is around 20 GeV, rising to ≃30 GeV after data analysis. Performance parameters depend strongly on energy, and on the strength of the gamma-ray selection cuts in the analysis: angular resolution ranges from 0.°12–0.°40, and energy resolution from 15%–50%. Flux sensitivity is around 1.1% of the Crab Nebula flux above 250 GeV for a 50 hr observation (12% for 30 minutes). The spectral energy distribution (in the 0.03–30 TeV range) and the light curve obtained for the Crab Nebula agree with previous measurements, considering statistical and systematic uncertainties. A clear periodic signal is also detected from the pulsar at the center of the Nebula.

17 March 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
DGDavid Sanchez Gonzalo
David Sanchez Gonzalo
SFSergio Gomez Fernández
Sergio Gomez Fernández
JMJoan Mauricio
Joan Mauricio
Lluís FreixasLluís Freixas
Lluís Freixas
ASAndreu Sanuy
Andreu Sanuy
DGDavid Gascon
David Gascon
Time-of-Flight positron emission tomography scanners demand fast and efficient photo sensors and scintillators coupled to fast readout electronics. This article presents the high resolution flexible Time-over-Threshold (HRFlexToT), a 16-channel application-specific-integrated circuit for silicon photomultipliers (SiPM) anode readout manufactured using XFAB 0.18- $\mu \text{m}$ CMOS technology. The main features of the HRFlexToT are a linear Time-over-Threshold with an extended dynamic range (10 bits) for energy measurement, low power consumption (≈ 3.5 mW/ch), and an excellent timing response. The experimental measurements show an energy linearity error of ≈ 3% and an energy resolution of about 12% at 511 keV. Single-photon time resolution measurements performed using an Fondazione Bruno Kessler (FBK) SiPM NUV-HD ( $4 \times 4$ mm 2 pixel, 40- $\mu \text{m}$ cell) and a Hamamatsu SiPM S13360-3050CS are around 142 and 167 ps full width at half maximum (FWHM), respectively. Coincidence time resolution (CTR) measurements with small cross-section pixelated crystals (LSO:Ce,Ca 0.4%, $2 \times 2 \times 5$ mm 3 ) coupled to the same Hamamatsu S13360-3050CS and FBK NUV-HD sensors yield a CTR of 117 ps and 119 ps, respectively. Measurements performed with a large cross-section monolithic crystal (LFS crystal measuring $25 \times 25 \times 20$ mm 3 ) and a Hamamatsu SiPM array S13361-6050NE-04 show a CTR of 324 ps FWHM after time-walk and time-skew correction.

1 October 2013
Verified
Conference Paper
Closed access
AMAlbert Comerma Montells
Albert Comerma Montells
David GasconDavid Gascon
David Gascon
Lluís FreixasLluís Freixas
Lluís Freixas
LGLluis Garrido
Lluis Garrido
RGRicardo Graciani
Ricardo Graciani
ISIciar Sarasola
Iciar Sarasola
A front end application specific integrated circuit (ASIC) for the readout of common cathode Silicon Photo-Multipliers arrays is presented with the following features: wide dynamic range, high speed, multi channel, low input impedance current amplifier, low power (≈10mW per channel), common cathode connection, directly coupled input with common mode voltage control and separated timing and charge signal output.A 16 channel prototype with 16 independent outputs for energy and pile-up detection and a single fast timing output is described. The low jitter current mode processing together with a configurable differential current mode logic (CML) output provides a timing signal suitable for Time of Flight (TOF) applications, such as TOF-PET (Positron Emission Tomography). Each channel delivers a digital output of a Time Over Threshold (TOT) type with a pulse width proportional to peak current (charge) input. The current mode input stage features a novel double feedback; a low speed feedback loop keeps input node voltage constant while a higher speed feedback loop keeps input impedance low. Dedicated circuitry allows SiPM high over-voltage operation, thus maximizing Photon Detection Efficiency (PDE) and timing resolution. Design was submitted in June 2012 in Austria Microsystems (AMS) 0.35 μm HBT BiCMOS technology and is under test.

14 March 2025 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
KAK. Abe
K. Abe
SAS. Abe
S. Abe
AAA. Abhishek
A. Abhishek
FAF. Acero
F. Acero
AAA. Aguasca-Cabot
A. Aguasca-Cabot
NZN. Zywucka
N. Zywucka
Context. The recurrent nova RS Ophiuchi (RS Oph) underwent a thermonuclear eruption in August 2021. In this event, RS Oph was detected by the High Energy Stereoscopic System (H.E.S.S.), the Major Atmospheric Gamma Imaging Cherenkov (MAGIC), and the first Large-Sized Telescope (LST-1) of the future Cherenkov Telescope Array Observatory (CTAO) at very-high gamma-ray energies above 100 GeV. This means that novae are a new class of very-high-energy (VHE) gamma-ray emitters. Aims. We report the analysis of the RS Oph observations with LST-1. We constrain the particle population that causes the observed emission in hadronic and leptonic scenarios. Additionally, we study the prospects of detecting further novae using LST-1 and the upcoming LST array of CTAO-North. Methods. We conducted target-of-opportunity observations with LST-1 from the first day of this nova event. The data were analysed in the framework of cta-lstchain and Gammapy, the official CTAO-LST reconstruction and analysis packages. One-zone hadronic and leptonic models were considered to model the gamma-ray emission of RS Oph using the spectral information from Fermi-LAT and LST-1, together with public data from the MAGIC and H.E.S.S. telescopes. Results. RS Oph was detected at 6.6σ with LST-1 in the first 6.35 hours of observations following the eruption. The hadronic scenario is preferred over the leptonic scenario considering a proton energy spectrum with a power-law model with an exponential cutoff whose position increases from (0.26 ± 0.08) TeV on day 1 up to (1.6 ± 0.6) TeV on day 4 after the eruption. The deep sensitivity and low energy threshold of the LST-1/LST array will allow us to detect faint novae and increase their discovery rate.

1 January 2013 in Journal of Instrumentation
Verified
Journal Article
Closed access
AMAlbert Comerma Montells
Albert Comerma Montells
David GasconDavid Gascon
David Gascon
LGL Garrido
L Garrido
CDCarlos Delgado
Carlos Delgado
JMJ Marín
J Marín
Lluís FreixasLluís Freixas
Lluís Freixas

29 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JMJoan Mauricio
Joan Mauricio
Lluís FreixasLluís Freixas
Lluís Freixas
ASAndreu Sanuy
Andreu Sanuy
SFSergio Gomez Fernández
Sergio Gomez Fernández
RMRafel Manera
Rafel Manera
David GasconDavid Gascon
David Gascon
This paper presents a highly configurable 16-channel TDC ASIC designed in a commercial 180 nm technology with the following features: time-of-flight and time-over-threshold measurements, 8.6 ps LSB, 7.7 ps jitter, 5.6 ps linearity error, up to 5 MHz of sustained input rate per channel, 9.1 mW of power consumption per channel, and an area of 4.57 mm2. The main contributions of this work are the novel design of the clock interpolation circuitry based on a resistive interpolation mesh circuit and the capability to operate at different supply voltages and operating frequencies, thus providing a compromise between TDC resolution and power consumption.