Laurent Peyrodie

Dr. Laurent Peyrodie

Department of Energy, Electricity and Automatic, HEI, 13 rue de Toul, 59046 Lille, France
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Neurocomputing
Verified
Journal Article
Closed access
XZXinyi Zhang
Xinyi Zhang
HWHaoping Wang
Haoping Wang
YTYang Tian
Yang Tian
LPLaurent Peyrodie
Laurent Peyrodie
XWXikun Wang
Xikun Wang

1 March 2019 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ALAgathe Houzé de L’aulnoit
Agathe Houzé de L’aulnoit
SBSamuel Boudet
Samuel Boudet
RDRomain Demailly
Romain Demailly
ADAline Delgranche
Aline Delgranche
MGMichaël Génin
Michaël Génin
DLDenis Houzé de L’aulnoit
Denis Houzé de L’aulnoit

1 November 2019 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
SBSamuel Boudet
Samuel Boudet
ALAgathe Houzé de L’aulnoit
Agathe Houzé de L’aulnoit
RDRomain Demailly
Romain Demailly
LPLaurent Peyrodie
Laurent Peyrodie
RBRégis Beuscart
Régis Beuscart
DLDenis Houzé de L’aulnoit
Denis Houzé de L’aulnoit

10 January 2023 in IEEE Access
Verified
Journal Article
Open access
YZYang Zhang
Yang Zhang
MBMathieu Bressel
Mathieu Bressel
SGSander De Groof
Sander De Groof
FDFrancois Domine
Francois Domine
LLLuc Labey
Luc Labey
LPLaurent Peyrodie
Laurent Peyrodie
Lower-limb exoskeletons have been proven to be beneficial for motor function disability patients, in both clinical rehabilitation settings and daily activities. However, exoskeletons for the pediatric field are still very limited. In this paper, a novel lower-limb exoskeleton design for children is presented. Based on the anthropometric data of the target group, the size of the exoskeleton is designed adjustable to suit children from 8 to 12 years old. It employs six active joints on the knee and hip, actuated by Brushless DC motors and Harmonic Drive gears. The controller is based on a finite state machine model and the weight shift between two feet to generate the gait trajectory. An innovative automatic step-triggering mechanism is also proposed, based on the feedback from the ground reaction force sensor on the foot. Two user interfaces on the exoskeleton and the host PC are designed for easily operating the exoskeleton by clinicians and engineers. Experiments have been conducted with three healthy volunteers following the predesigned rehabilitation session protocol. Results show that the exoskeleton can well follow the gait trajectory generated by the control algorithm. All volunteers can fulfill all tasks in the test protocol with reduced efforts and the steps are automatically triggered by the presented controller.

11 February 2007 in Signal Processing
Verified
Journal Article
Closed access
SBSamuel Boudet
Samuel Boudet
LPLaurent Peyrodie
Laurent Peyrodie
PGPhilippe Gallois
Philippe Gallois
CVChristian Vasseur
Christian Vasseur

27 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SBSamuel Boudet
Samuel Boudet
ALAgathe Houzé de L’aulnoit
Agathe Houzé de L’aulnoit
LPLaurent Peyrodie
Laurent Peyrodie
RDRomain Demailly
Romain Demailly
DLDenis Houzé de L’aulnoit
Denis Houzé de L’aulnoit
We have developed deep learning models for automatic identification of the maternal heart rate (MHR) and, more generally, false signals (FSs) on fetal heart rate (FHR) recordings. The models can be used to preprocess FHR data prior to automated analysis or as a clinical alert system to assist the practitioner. Three models were developed and used to detect (i) FSs on the MHR channel (the FSMHR model), (ii) the MHR and FSs on the Doppler FHR sensor (the FSDop model), and (iii) FSs on the scalp ECG channel (the FSScalp model). The FSDop model was the most useful because FSs are far more frequent on the Doppler FHR channel. All three models were based on a multilayer, symmetric, GRU, and were trained on data recorded during the first and second stages of delivery. The FSMHR and FSDop models were also trained on antepartum recordings. The training dataset contained 1030 expert-annotated periods (mean duration: 36 min) from 635 recordings. In an initial evaluation of routine clinical practice, 30 fully annotated recordings for each sensor type (mean duration: 5 h for MHR and Doppler sensors, and 3 h for the scalp ECG sensor) were analyzed. The sensitivity, positive predictive value (PPV) and accuracy were respectively 62.20%, 87.1% and 99.90% for the FSMHR model, 93.1%, 95.6% and 99.68% for the FSDop model, and 44.6%, 87.2% and 99.93% for the FSScalp model. We built a second test dataset with a more solid ground truth by selecting 45 periods (lasting 20 min, on average) on which the Doppler FHR and scalp ECG signals were recorded simultaneously. Using scalp ECG data, the experts estimated the true FHR value more reliably and thus annotated the Doppler FHR channel more precisely. The models achieved a sensitivity of 53.3%, a PPV of 62.4%, and an accuracy of 97.29%. In comparison, two experts (blinded to the scalp ECG data) respectively achieved a sensitivity of 15.7%, a PPV of 74.3%, and an accuracy of 96.91% and a sensitivity of 60.7%, a PPV of 83.5% and an accuracy of 98.24%. Hence, the models performed at expert level (better than one expert and worse than the other), although a well-trained expert with good knowledge of FSs could probably do better in some cases. The models and datasets have been included in the Fetal Heart Rate Morphological Analysis open-source MATLAB toolbox and can be used freely for research purposes.