5 September 2019 in IEEE Transactions on Industrial Electronics
Single-stage, single-phase photovoltaic (PV) distributed generation (DG) systems rated below 5 kW are becoming popular because of the reduction in the cost of PV panels and also due to various policy initiatives. One cycle control (OCC) based inverters are ideally suitable for such DG systems because of its cost-effectiveness, simple structure, and phase-locked loop free implementation. These inverter-based DG systems should have a robust islanding detection method (IDM) incorporated into it and should fulfill the recent standard requirements. This article proposes a novel feedback-based passive IDM, which is suitable for OCC-based grid-connected PV inverter system. The proposed method relies on the inbuilt feedback nature of OCC-based system, which drives the voltage at the point of common coupling outside the normal range of operation during an islanding condition. The proposed IDM works effectively under the new standard requirements with negligible nondetection zone. The IDM does not rely on additional computational effort or injection of external disturbance into the grid. Simulation studies are performed to verify the effectiveness of the proposed IDM. A laboratory prototype has been developed, and experimental studies are conducted to ascertain the viability of the proposed method.
12 September 2022 in IEEE Access
CACrestian Almazan Agustin
In this paper, a modulated dual-voltage-vector model-free predictive current control with online duty cycle calculation is proposed and applied to drive a synchronous reluctance motor. The dual-voltage-vector modulation scheme reduces the current ripples and errors in the single-voltage-vector method. The proposed method reduces the predictive current controller’s calculation time by first setting the initial value of the duty cycle to a constant. Then, an optimal switching mode can be selected by minimizing a cost function. Next, the required duty cycle can be calculated directly by the proposed method without any differential calculations instead of its initial value. The proposed method can effectively track the stator current, reducing the maximum average current error by 34.8% compared to the conventional single-voltage-vector scheme. Finally, the correctness and feasibility of the modulated model-free predictive current controller with the online duty cycle calculation proposed in this article are verified by the experimental results using Texas Instruments microcontroller TMS320F28379D.
26 July 2021 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Features like phase-locked-loop free implementation, simple-structure, grid voltage sensor-less operation, and its feedback response make one-cycle-control (OCC) inverters suitable and cost-effective for small singlephase photovoltaic distributed-generator (DG) units. The feedback nature of OCC makes passive islanding detection more effective in comparison with other control methods. A novel hybrid islanding detection method (IDM), which is suitable for OCC inverters, is proposed in this paper. The hybridization is done in two levels and is aimed at reducing the non-detection zone (NDZ) of the existing feedback based passive IDM. The passive first level defense, which is always present, is due to the feedback-nature of OCC. When islanding is suspected, the active second level defense is initiated by injecting a short real power disturbance. This accelerates the feedback action and helps in timely detection of islanding. Unlike other active methods, the disturbance is injected only when an islanding condition is suspected. The induced disturbance in real power is momentary, and the inverter goes back to the normal operation under non-islanded conditions. Simulation and experimental studies are performed to verify the effectiveness of the proposed IDM.