Georgios Romanos

Prof. Dr. Georgios Romanos

Stony Brook University Health Science Center, School of Dental Medicine, Dept. of Periodontology
+1
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Rafael Delgado RuizRafael Delgado Ruiz
Rafael Delgado Ruiz
Georgios RomanosGeorgios Romanos
Georgios Romanos
Implant surface characteristics, as well as physical and mechanical properties, are responsible for the positive interaction between the dental implant, the bone and the surrounding soft tissues. Unfortunately, the dental implant surface does not remain unaltered and changes over time during the life of the implant. If changes occur at the implant surface, mucositis and peri-implantitis processes could be initiated; implant osseointegration might be disrupted and bone resorption phenomena (osteolysis) may lead to implant loss. This systematic review compiled the information related to the potential sources of titanium particle and ions in implant dentistry. Research questions were structured in the Population, Intervention, Comparison, Outcome (PICO) framework. PICO questionnaires were developed and an exhaustive search was performed for all the relevant studies published between 1980 and 2018 involving titanium particles and ions related to implant dentistry procedures. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed for the selection and inclusion of the manuscripts in this review. Titanium particle and ions are released during the implant bed preparation, during the implant insertion and during the implant decontamination. In addition, the implant surfaces and restorations are exposed to the saliva, bacteria and chemicals that can potentially dissolve the titanium oxide layer and, therefore, corrosion cycles can be initiated. Mechanical factors, the micro-gap and fluorides can also influence the proportion of metal particles and ions released from implants and restorations.

1 October 1999 in Journal of Clinical Laser Medicine & Surgery
Verified
Journal Article
Closed access
Georgios RomanosGeorgios Romanos
Georgios Romanos
GNGeorg-Hubertus Nentwig
Georg-Hubertus Nentwig
The aim of this study was to examine the wound healing of soft tissue after the application of a diode laser (980 nm) in oral surgical procedures. Like the CO2 laser, the diode laser can be used for soft tissue surgery without extensive experience in the field of oral surgical. A diode laser was used to treat a variety of oral soft tissue lesions in 22 patients. The oral surgical procedures included removal of soft tissue tumors, frenectomies, excision of gingival hyperplasias, vestibuloplasties, hemangioma removal, and periimplant soft tissue surgery. The laser was used in both pulsed and continuous modes, with and without contact to the tissue. Intraoperative and postoperative clinical observations are reported. Our preliminary clinical findings include sufficient hemostasis and precise incision margin with all of the surgical procedures. The coagulation properties, associated with the use of a diode laser, were particularly beneficial during removal of vascular lesions. The postoperative advantages, i.e., lack of swelling, bleeding, pain or, scar tissue formation, and the good wound healing were observed in all of the clinical applications and were dependent only on the laser physical parameters used. The clinical application of the diode (980 nm) laser in oral and maxillofacial surgical procedures seems to be of beneficial effect for daily practice.

21 October 2020 in International Dental Journal
Verified
Journal Article
Closed access
FKFouad Khoury
Fouad Khoury
PKPhilip L Keeve
Philip L Keeve
ARAusra Ramanauskaite
Ausra Ramanauskaite
FSFrank Schwarz
Frank Schwarz
KKKi-Tae Koo
Ki-Tae Koo
Georgios RomanosGeorgios Romanos
Georgios Romanos

1 May 2000 in Journal of Periodontology
Verified
Journal Article
Closed access
Georgios RomanosGeorgios Romanos
Georgios Romanos
HEHayo Everts
Hayo Everts
GNGeorg H. Nentwig
Georg H. Nentwig
Background: Dental lasers have been recommended for uncovering submerged implants as well as decontaminating implant surfaces when treating peri‐implantitis. The aim of this study was to show the possible alterations in titanium disc surfaces using an Nd:YAG or a diode laser.Methods: Three different titanium discs were used (sandblasted, titanium plasma‐sprayed [TPS], and hydroxyapatite [HA] coated) to determine the effects of laser irradiation on these surfaces using a scanning electron microscope (SEM). The discs were either irradiated with a pulsed Nd:YAG laser with a contact handpiece and power settings of 2.0, 4.0, and 6.0W or with a diode laser at 5.0, 10.0, and 15.0W power settings and continuous wave (cw) in the contact handpiece. Irradiated areas were compared with control titanium sites which were not lased. The specimens were prepared for SEM examination after the disc irradiation.Results: The SEM examination demonstrated extensive melting in all of the Nd:YAG laser irradiated areas. Damage was seen in all TPS‐ and HA‐coated discs even at the lowest power setting. Loss of porosity, coating microfractures, and a relatively smooth surface were observed. In contrast, the diode laser did not cause any damage or modify the disc surface. Regardless of the power setting, there was no visible difference between lased and non‐lased surfaces after cw irradiation with the diode laser.Conclusions: From these findings, it was concluded that the diode laser (980 nm) does not damage titanium surfaces, which should be of value when uncovering submerged implants and treating peri‐implantitis. J Periodontol 2000;71:810‐815.

12 January 2016 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
MAMohammad D. Al Amri
Mohammad D. Al Amri
SKSergio Varela Kellesarian
Sergio Varela Kellesarian
AAAbdulaziz A. Al‐Kheraif
Abdulaziz A. Al‐Kheraif
HMHans Malmstrom
Hans Malmstrom
Fawad JavedFawad Javed
Fawad Javed
Georgios RomanosGeorgios Romanos
Georgios Romanos

1 April 2001 in Journal of Periodontology
Verified
Journal Article
Closed access
Georgios RomanosGeorgios Romanos
Georgios Romanos
CTChooi Gait Toh
Chooi Gait Toh
CSChong Huat Siar
Chong Huat Siar
DSDasan Swaminathan
Dasan Swaminathan
AOAh Hup Ong
Ah Hup Ong
GNGeorg‐Hubertus Nentwig
Georg‐Hubertus Nentwig
Background: There are reports which demonstrate that immediately loaded splinted implants can be osseointegrated when they are placed in the anterior part of the lower jaw. The concept of immediate loading has not been well investigated in the posterior mandible. The aim of this study was to evaluate the bone reactions around immediately loaded implants placed in the posterior region of the lower jaw in the monkey model.Methods: Six adult Macaca fascicularis monkeys were used in this study. A total of 36 implants were placed after extraction of the second premolars, first and second molars, and complete healing of the sockets. Three control (C) group implants were placed in one quadrant of the lower jaw of each monkey. After a delay of 3 months to allow osseointegration to take place, the implants were loaded for 1 month using temporary resin bridges and later for 2 months using metal splinted crowns. In the contralateral region of the lower jaw, 3 test (T) group implants were placed and loaded immediately with the same sequence as carried out for the C implants. Specimens were examined and evaluated histologically after sacrifice.Results: All of the implants were osseointegrated. Compact, cortical bone in contact with the implant surface without any gaps or connective tissue formation was observed.Conclusions: It was concluded that immediately loaded, splinted implants can be osseointegrated with a similar hard and soft tissue peri‐implant response as delayed‐loaded implants in the posterior mandible. J Periodontol 2001;72:506‐511.