Erik Edström

Dr. Erik Edström

Department of Clinical Neuroscience, Karolinska Institutet, SE-171 65 Stockholm, Sweden
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Spine
Verified
Journal Article
Open access
AEAdrian Elmi-Terander
Adrian Elmi-Terander
GBGustav Burström
Gustav Burström
RNRami Nachabe
Rami Nachabe
HSHalldor Skulason
Halldor Skulason
KPKyrre Pedersen
Kyrre Pedersen
PGPaul Gerdhem
Paul Gerdhem
Study Design.: Prospective observational study. Objective.: The aim of this study was to evaluate the accuracy of pedicle screw placement using augmented reality surgical navigation (ARSN) in a clinical trial. Summary of Background Data.: Recent cadaveric studies have shown improved accuracy for pedicle screw placement in the thoracic spine using ARSN with intraoperative 3D imaging, without the need for periprocedural x-ray. In this clinical study, we used the same system to place pedicle screws in the thoracic and lumbosacral spine of 20 patients. Methods.: The study was performed in a hybrid operating room with an integrated ARSN system encompassing a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Three independent reviewers assessed screw placement accuracy using the Gertzbein grading on 3D scans obtained before wound closure. In addition, the navigation time per screw placement was measured. Results.: One orthopedic spinal surgeon placed 253 lumbosacral and thoracic pedicle screws on 20 consenting patients scheduled for spinal fixation surgery. An overall accuracy of 94.1% of primarily thoracic pedicle screws was achieved. No screws were deemed severely misplaced (Gertzbein grade 3). Fifteen (5.9%) screws had 2 to 4 mm breach (Gertzbein grade 2), occurring in scoliosis patients only. Thirteen of those 15 screws were larger than the pedicle in which they were placed. Two medial breaches were observed and 13 were lateral. Thirteen of the grade 2 breaches were in the thoracic spine. The average screw placement time was 5.2 ± 4.1 minutes. During the study, no device-related adverse event occurred. Conclusion.: ARSN can be clinically used to place thoracic and lumbosacral pedicle screws with high accuracy and with acceptable navigation time. Consequently, the risk for revision surgery and complications could be minimized. Level of Evidence: 3

1 July 2006 in The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
Verified
Journal Article
Open access
PDF file
EEErik Edström
Erik Edström
MAMikael Altun
Mikael Altun
MHMartin Hägglund
Martin Hägglund
BUBrun Ulfhake
Brun Ulfhake
Muscle atrophy in many conditions share a common mechanism in the upregulation of the muscle-specific ubiquitin E3-ligases atrophy gene-1/muscle atrophy F-box (Atrogin-1/MAFbx) and muscle ring-finger protein 1 (MuRF1). E3-ligases are part of the ubiquitin proteasome pathway utilized for protein degradation during muscle atrophy. In this study, we provide new data to show that this is not the case in age-related loss of muscle mass (sarcopenia). On the contrary, Atrogin-1/MAFbx and MuRF1 are downregulated in skeletal muscle of 30-month-old rats, and our results suggest that AKT (protein kinase B)-mediated inactivation of forkhead box O 4 (FOXO4) underlies this suppression. The data also suggest that activation of AKT is mediated through the insulin-like growth factor-1 (IGF-1) receptor, signaling via ShcA-Grb2-GAB. Using dietary restriction, we find that it impedes sarcopenia as well as the effects of aging on AKT phosphorylation, FOXO4 phosphorylation, and Atrogin-1/MAFbx and MuRF1 transcript regulation. We conclude that sarcopenia is mechanistically different from acute atrophies induced by disuse, disease, and denervation.

1 September 2007 in Physiology & Behavior
Verified
Journal Article
Closed access
EEErik Edström
Erik Edström
MAMikael Altun
Mikael Altun
EBEsbjörn Bergman
Esbjörn Bergman
HJHans Johnson
Hans Johnson
SKSusanna Kullberg
Susanna Kullberg
BUBrun Ulfhake
Brun Ulfhake

1 March 2007 in Biochemical Pharmacology
Verified
Journal Article
Closed access
OKOlga Karovic
Olga Karovic
Ilaria TonazziniIlaria Tonazzini
Ilaria Tonazzini
NRNelson Rebola
Nelson Rebola
EEErik Edström
Erik Edström
CLCecilia Lövdahl
Cecilia Lövdahl
EDElisabetta Daré
Elisabetta Daré

1 December 2007 in Physiology & Behavior
Verified
Journal Article
Closed access
MAMikael Altun
Mikael Altun
EBEsbjörn Bergman
Esbjörn Bergman
EEErik Edström
Erik Edström
HJHans Johnson
Hans Johnson
BUBrun Ulfhake
Brun Ulfhake

15 July 2018 in Spine
Verified
Journal Article
Open access
AEAdrian Elmi-Terander
Adrian Elmi-Terander
RNRami Nachabe
Rami Nachabe
HSHalldor Skulason
Halldor Skulason
KPKyrre Pedersen
Kyrre Pedersen
MSMichael Söderman
Michael Söderman
EEErik Edström
Erik Edström
Study Design.: Cadaveric laboratory study. Objective.: To assess the feasibility and accuracy of minimally invasive thoracolumbar pedicle screw placement using augmented reality (AR) surgical navigation. Summary of Background Data.: Minimally invasive spine (MIS) surgery has increasingly become the method of choice for a wide variety of spine pathologies. Navigation technology based on AR has been shown to be feasible, accurate, and safe in open procedures. AR technology may also be used for MIS surgery. Methods.: The AR surgical navigation was installed in a hybrid operating room (OR). The hybrid OR includes a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D imaging capabilities, integrated optical cameras for AR navigation, and patient motion tracking using optical markers on the skin. Navigation and screw placement was without any x-ray guidance. Two neurosurgeons placed 66 Jamshidi needles (two cadavers) and 18 cannulated pedicle screws (one cadaver) in the thoracolumbar spine. Technical accuracy was evaluated by measuring the distance between the tip of the actual needle position and the corresponding planned path as well as the angles between the needle and the desired path. Time needed for navigation along the virtual planned path was measured. An independent reviewer assessed the postoperative scans for the pedicle screws’ clinical accuracy. Results.: Navigation time per insertion was 90 ± 53 seconds with an accuracy of 2.2 ± 1.3 mm. Accuracy was not dependent on operator. There was no correlation between navigation time and accuracy. The mean error angle between the Jamshidi needles and planned paths was 0.9° ± 0.8°. No screw was misplaced outside the pedicle. Two screws breached 2 to 4 mm yielding an overall accuracy of 89% (16/18). Conclusion.: MIS screw placement directed by AR with intraoperative 3D imaging in a hybrid OR is accurate and efficient, without any fluoroscopy or x-ray imaging during the procedure. Level of Evidence: N/A