Jae-Hong Kim

Prof. Jae-Hong Kim

Dental Laboratory Science, Catholic University of Pusan, Busan, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
JPJin-Young Park
Jin-Young Park
Hae-Young KimHae-Young Kim
Hae-Young Kim
JKJi-Hwan Kim
Ji-Hwan Kim
JKJae-Hong Kim
Jae-Hong Kim
WKWoong-Chul Kim
Woong-Chul Kim
Park JY, et al. J Adv Prosthodont. 2015 Aug;7(4):294-302. https://doi.org/10.4047/jap.2015.7.4.294

1 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JKJae-Hong Kim
Jae-Hong Kim
Seunghan OhSeunghan Oh
Seunghan Oh
SUSoo-Hyuk Uhm
Soo-Hyuk Uhm
The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a pairedt-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α=0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P<0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120μm, which is the clinically acceptable threshold.

28 December 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MKMin-Young Kim
Min-Young Kim
HCHyunmin Choi
Hyunmin Choi
JLJae Hoon Lee
Jae Hoon Lee
JKJee-Hwan Kim
Jee-Hwan Kim
Han-Sung JungHan-Sung Jung
Han-Sung Jung
Hong Seok MoonHong Seok Moon
Hong Seok Moon
The purpose of this study was to compare and evaluate, through histomorphometric and radiological analysis, the effects of UV photofunctionalization on an implant placed over a critical defect area with and without a bone graft. Four female beagle dogs were first divided into control and bone graft groups. Each group was then subdivided into UV-treated and UV-untreated groups. The mandibular premolars in each dog were extracted. 12 weeks after extraction, implants were placed according to the condition of each group. Four and 12 weeks after implantation on left and right mandible, the dogs were sacrificed. The specimens were prepared for histomorphometric and micro-computed tomographic analysis. In both 4-week and 12-week groups, UV-treated implant surfaces showed better osseointegration than SA implant surfaces. Also, with implant surfaces placed over the critical defect with bone graft, UV photofunctionalization increased bone-to-implant contact (BIC) and new bone formation at the initial stage (4 weeks). Based on the results of this study, it can be suggested that UV photofunctionalization on the surface of implants placed over large critical defects with bone graft aids initial osseointegration and osteogenesis.

1 January 2014 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
KKKi-Baek Kim
Ki-Baek Kim
JKJae-Hong Kim
Jae-Hong Kim
WKWoong-Chul Kim
Woong-Chul Kim
JKJi-Hwan Kim
Ji-Hwan Kim
The purpose of this study was to investigate, by measuring the gap, the possible clinical use of three-unit fixed dental prostheses (FDPs) manufactured using stereolithography. A total of 20 epoxy models were built with a same case (abutment teeth 14, 16). The 40 specimens were produced using the stereolithography (SLA) and wax-up (LW). The 960 gaps of the 40 specimens produced were measured by a silicone replica. The Wilcoxon rank sum test was then used to compare and analyze the data obtained from the two groups (α=0.05). The total gap, as measured from the SLA and LW groups, was 98.6 and 66.6 µm, respectively. The results indicate that the gap in the SLA group is statistically significantly greater than that in the LW group (p<0.05). Further assessment and improvement of the SLA method for the fabrication of FDPs is evidently still required.

1 January 2015 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
KKKi-Baek Kim
Ki-Baek Kim
JKJae-Hong Kim
Jae-Hong Kim
SKSa-Hak Kim
Sa-Hak Kim
Kim KB, et al. J Adv Prosthodont. 2015 Jun;7(3):199-206. https://doi.org/10.4047/jap.2015.7.3.199

28 November 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
TKTae-Gyung Kim
Tae-Gyung Kim
SKSungtae Kim
Sungtae Kim
HCHyunmin Choi
Hyunmin Choi
JLJae Hoon Lee
Jae Hoon Lee
JKJae-Hong Kim
Jae-Hong Kim
Hong Seok MoonHong Seok Moon
Hong Seok Moon
The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P<0.05). No significant difference was observed between the CAD/CAM group and the cast group (P>0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.