Luis Martí-Bonmatí

Dr. Luis Martí-Bonmatí

1. Grupo de Investigación Biomédica en Imagen, Instituto de Investigación Sanitaria La Fe, 46026 Valencia, Spain
+1

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
JMJosé V. Manjón
José V. Manjón
PCPierrick Coupé
Pierrick Coupé
Luis Martí-BonmatíLuis Martí-Bonmatí
Luis Martí-Bonmatí
DCD. Louis Collins
D. Louis Collins
MRMontserrat Robles
Montserrat Robles
Purpose: To adapt the so‐called nonlocal means filter to deal with magnetic resonance (MR) images with spatially varying noise levels (for both Gaussian and Rician distributed noise).Materials and Methods: Most filtering techniques assume an equal noise distribution across the image. When this assumption is not met, the resulting filtering becomes suboptimal. This is the case of MR images with spatially varying noise levels, such as those obtained by parallel imaging (sensitivity‐encoded), intensity inhomogeneity‐corrected images, or surface coil‐based acquisitions. We propose a new method where information regarding the local image noise level is used to adjust the amount of denoising strength of the filter. Such information is automatically obtained from the images using a new local noise estimation method.Results: The proposed method was validated and compared with the standard nonlocal means filter on simulated and real MRI data showing an improved performance in all cases.Conclusion: The new noise‐adaptive method was demonstrated to outperform the standard filter when spatially varying noise is present in the images. J. Magn. Reson. Imaging 2010;31:192–203.

1 August 2008 in Medical Image Analysis
Verified
Journal Article
Closed access
JMJ Manjon
J Manjon
JCJosé Carbonell-Caballero
José Carbonell-Caballero
JLJ Lull
J Lull
GGG Garciamarti
G Garciamarti
Luis Martí-BonmatíLuis Martí-Bonmatí
Luis Martí-Bonmatí
MRM Robles
M Robles

17 January 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
NMNathaniel Mercaldo
Nathaniel Mercaldo
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
BBBettina Baeßler
Bettina Baeßler
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical

1 August 2007 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Open access
PDF file
CAClaudio Álvarez
Claudio Álvarez
Luis Martí-BonmatíLuis Martí-Bonmatí
Luis Martí-Bonmatí
ENEdurne Novella-Maestre
Edurne Novella-Maestre
RSRoberto Sanz-Requena
Roberto Sanz-Requena
RGRaúl Gómez
Raúl Gómez
APAntonio Pellicer
Antonio Pellicer
Context: Ovarian hyperstimulation syndrome (OHSS) results from increased vascular permeability (VP) caused by ovarian hypersecretion of vascular endothelial growth factor (VEGF), which activates its receptor-2. In animals, the dopamine receptor 2 agonist cabergoline (Cb2) inactivates VEGF receptor-2 and prevents increased VP. Objective: Our objective was to test whether Cb2 reduces VP and prevents OHSS in humans. Design: We conducted a prospective, randomized, double-blind study on oocyte donors at risk of developing OHSS (>20 follicles, >12 mm developed, and >20 oocytes retrieved). Interventions: Cb2 0.5 mg/d (n = 37) or a placebo (n = 32) was administered from the day of human chorionic gonadotropin (d 0) until d 8. Ascites (a pocket of peritoneal fluid > 9 cm2 in lithotomy position), hemoconcentration, and serum prolactin were recorded. Pharmacokinetic studies with magnetic resonance employing the transfer constant rate (Ktrans, measure of permeability) and the extravascular extracellular space (υe, marker of cellular leakage) were performed to measure VP objectively. Results: Hematocrit (P < 0.01), hemoglobin (P = 0.003), and ascites (P = 0.005) were significantly lower on d 4 and 6 after treatment with Cb2 as compared with placebo. The incidence of moderate OHSS was 20.0 and 43.8%, respectively (P = 0.04). Magnetic resonance studies showed an increase in VP and extravascular leakage of fluid 5 d after human chorionic gonadotropin injection that was significantly prevented with Cb2 (KtransP = 0.04 and υeP = 0.001, respectively). Conclusions: Given that Cb2 is a well-established and safe medication, this study provides proof of concept for the use of dopamine agonists in the prevention of OHSS in women undergoing assisted reproduction.

1 April 2023 in Radiology
Verified
Journal Article
Closed access
SRScott B. Reeder
Scott B. Reeder
TYTakeshi Yokoo
Takeshi Yokoo
MFManuela França
Manuela França
DHDiego Hernando
Diego Hernando
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
Luis Martí-BonmatíLuis Martí-Bonmatí
Luis Martí-Bonmatí
Based on the available literature and the collective expertise of this consensus panel, confounder-corrected R2*-based liver iron concentration (LIC) is the preferred method with the strongest leve... Accumulation of excess iron in the body, or systemic iron overload, results from a variety of causes. The concentration of iron in the liver is linearly related to the total body iron stores and, f...

25 June 2004 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
MMM.Carmen Martínez-Bisbal
M.Carmen Martínez-Bisbal
Luis Martí-BonmatíLuis Martí-Bonmatí
Luis Martí-Bonmatí
JPJosé Piquer
José Piquer
ARAntonio Revert
Antonio Revert
PFPilar Ferrer
Pilar Ferrer
BCBernardo Celda
Bernardo Celda