José Anchieta Gomes Neto

José Anchieta Gomes Neto

Auto-generated profile, based on publicly available information

José Anchieta Gomes Neto


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
EOEvilim M. Oliveira
Evilim M. Oliveira
MRMarilia Rogero
Marilia Rogero
EFEdilene C. Ferreira
Edilene C. Ferreira
JNJosé A. Gomes Neto
José A. Gomes Neto


23 March 2012 in Microchemical Journal
Verified
Journal Article
Closed access
PDF file
MBMarcos André Bechlin
Marcos André Bechlin
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
JNJoaquim Araújo Nóbrega
Joaquim Araújo Nóbrega

30 November 2005 in Food Chemistry
Verified
Journal Article
Closed access
AOAdriana Paiva Oliveira
Adriana Paiva Oliveira
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
JNJoaquim Araújo Nóbrega
Joaquim Araújo Nóbrega
Paulo R.M. CorreiaPaulo R.M. Correia
Paulo R.M. Correia
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira

24 October 2002 in Food Chemistry
Verified
Journal Article
Closed access
CRCássia Regina Rosa
Cássia Regina Rosa
MMMercedes de Moraes
Mercedes de Moraes
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
JNJoaquim Araújo Nóbrega
Joaquim Araújo Nóbrega
ANAna Rita Nogueira
Ana Rita Nogueira

29 November 2001 in The Analyst
Verified
Journal Article
Closed access
PDF file
KFKelly G. Fernandes
Kelly G. Fernandes
MMMercedes de Moraes
Mercedes de Moraes
JNJosé A. Gomes Neto
José A. Gomes Neto
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
POPedro V. Oliveira
Pedro V. Oliveira
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)2 plus Mg(NO3)2 as chemical modifier to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0–50 μg l−1 Pb in 0.2% v/v HNO3 ) were spiked with 25 μg l−1 Bi. For a 20 μl aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rosé wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91–104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 μg l−1 Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.