Disc herniation is one of the most ubiquitous healthcare problems in modern cities—severe patients eventually require surgical intervention. However, the existing operations—spinal fusion and artificial disc replacement—alter the biomechanics of the spine, leaving much room for improvement. The appropriateness of polyvinyl alcohol (PVA) for biomedical applications has been recognised due to its high water content, excellent biocompatibility, and versatile mechanical properties. In this study, a newly-designed PVA–bacterial cellulose (PVA-BC) composite was assembled to mimic both the biomechanics and annular structure of natural intervertebral discs (IVDs). PVA-BC composites of various concentrations were fabricated and tested under unconfined compression and compressive creep in order to acquire the values of the normalised compressive stiffness and whole normalised deformation. The normalised compressive stiffness increased considerably with an increasing PVA concentration, spanning from 1.82 (±0.18) to 3.50 (±0.14) MPa, and the whole normalised deformation decreased from 0.25 to 0.13. Formulations of 40% PVA provided the most accurate mimicry of natural human IVDs in normalised whole deformation, and demonstrated higher dimensional stability. The biocompatible results further confirmed that the materials had excellent biocompatibility. The novel bionic structure and formulations of the PVA-BC materials mimicked the biomechanics and structure of natural IVDs, and ensured dimensional stability under prolonged compression, reducing the risk of impingement on the surrounding tissue. The PVA-BC composite is a promising material for third-generation artificial IVDs with integrated construction.
Creep responses of intervertebral discs (IVDs) are essential for spinal biomechanics clarification. Yet, there still lacks a well-recognized investigation protocol for this phenomenon. Current work aims at providing researchers with an overview of the in vitro creep tests reported by previous studies, specifically specimen species, testing environment, loading regimes and major results, based on which a preliminary consensus that may guide future creep studies is proposed. Specimens used in creep studies can be simplified as a “bone–disc–bone” structure where three mathematical models can be adopted for describing IVDs’ responses. The preload of 10–50 N for 30 min or three cycles followed by 4 h-creep under constant compression is recommended for ex vivo simulation of physiological condition of long-time sitting or lying. It is worth noticing that species of specimens, environment temperature and humidity all have influences on biomechanical behaviors, and thus are summarized and compared through the literature review. All factors should be carefully set according to a guideline before tests are conducted to urge comparable results across studies. To this end, this review also provides a guideline, as mentioned before, and specific steps that might facilitate the community of biomechanics to obtain more repeatable and comparable results from both natural specimens and novel biomaterials.
Creep-associated changes in disc bulging and axial strains are essential for the research and development of mechano-bionic biomaterials and have been assessed in various ways in ex vivo creep studies. Nonetheless, the reported methods for measurement were limited by location inaccuracy, a lack of synchronousness, and destructiveness. To this end, this study focuses on the accurate, synchronous, and noninvasive assessment of bugling and strains using the 3D digital image correlation (3D-DIC) system and the impact of creep on them. After a preload of 30 min, the porcine cervical discs were loaded with different loads for 4 h of creep. Axial strains and lateral bulging of three locations on the discs were synchronously measured. The three-parameter solid model and the newly proposed horizontal asymptote model were used to fit the acquired data. The results showed that the load application reduced disc strains by 6.39% under 300 N, 11.28% under 400 N, and 12.59% under 500 N. Meanwhile, the largest protrusion occurred in the middle of discs with a bugling of 1.50 mm, 1.67 mm, and 1.87 mm. Comparison of the peer results showed that the 3D-DIC system could be used in ex vivo biomechanical studies with reliability and had potential in the assessment of the mechanical behavior of novel biomaterials. The phenomenon of the largest middle protrusion enlightened further the strength of spinal implants in this area. The mathematical characterizations of bulging and strains under different loads yielded various model parameters, which are prerequisites for developing implanted biomaterials.