Masateru Kawakubo

Dr. Masateru Kawakubo

Saga University, Saga, Japan
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
AWAdi Wibowo
Adi Wibowo
PTPandji Triadyaksa
Pandji Triadyaksa
ASAris Sugiharto
Aris Sugiharto
ESEko Adi Sarwoko
Eko Adi Sarwoko
FNFajar Agung Nugroho
Fajar Agung Nugroho
MKMasateru Kawakubo
Masateru Kawakubo
Cardiac cine magnetic resonance imaging (MRI) is a widely used technique for the noninvasive assessment of cardiac functions. Deep neural networks have achieved considerable progress in overcoming various challenges in cine MRI analysis. However, deep learning models cannot be used for classification because limited cine MRI data are available. To overcome this problem, features from cine image settings are derived by handcrafting and addition of other clinical features to the classical machine learning approach for ensuring the model fits the MRI device settings and image parameters required in the analysis. In this study, a novel method was proposed for classifying heart disease (cardiomyopathy patient groups) using only segmented output maps. In the encoder–decoder network, the fully convolutional EfficientNetB5-UNet was modified to perform the semantic segmentation of the MRI image slice. A two-dimensional thickness algorithm was used to combine the segmentation outputs for the 2D representation of images of the end-diastole (ED) and end-systole (ES) cardiac volumes. The thickness images were subsequently used for classification by using a few-shot model with an adaptive subspace classifier. Model performance was verified by applying the model to the 2017 MICCAI Medical Image Computing and Computer-Assisted Intervention dataset. High segmentation performance was achieved as follows: the average Dice coefficients of segmentation were 96.24% (ED) and 89.92% (ES) for the left ventricle (LV); the values for the right ventricle (RV) were 92.90% (ED) and 86.92% (ES). The values for myocardium were 88.90% (ED) and 90.48% (ES). An accuracy score of 92% was achieved in the classification of various cardiomyopathy groups without clinical features. A novel rapid analysis approach was proposed for heart disease diagnosis, especially for cardiomyopathy conditions using cine MRI based on segmented output maps.

21 February 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
MKMasateru Kawakubo
Masateru Kawakubo
YYYuzo Yamasaki
Yuzo Yamasaki
TKTakeshi Kamitani
Takeshi Kamitani
KSKoji Sagiyama
Koji Sagiyama
YMYuko Matsuura
Yuko Matsuura
HHHiroshi Honda
Hiroshi Honda

27 April 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
RKRisa Kanatani
Risa Kanatani
TSTakashi Shirasaka
Takashi Shirasaka
TKTsukasa Kojima
Tsukasa Kojima
TKToyoyuki Kato
Toyoyuki Kato
MKMasateru Kawakubo
Masateru Kawakubo
In this study, we investigated the influence of beam hardening on the dual-energy computed tomography (DECT) values of iodine maps, virtual monoenergetic (VME) images, and virtual non-contrast (VNC) images. 320-row DECT imaging was performed by changing the x-ray tube energy for the first and second rotations. DECT values of 5 mg/mL iodine of the multi-energy CT phantom were compared with and without a 2-mm-thick attenuation rubber layer (~700 HU) wound around the phantom. It was found that the CT density values UH, with/without the rubber layer had statistical differences in the iodine map (184 ± 0.7 versus 186 ± 1.8), VME images (125 ± 0.3 versus 110 ± 0.4), and VNC images (−58 ± 0.7 versus −76 ± 1.7) (p < 0.010 for all). This suggests that iodine mapping may be underestimated by DECT and overestimated by VME imaging because of x-ray beam hardening. The use of VNC images instead of plain CT images requires further investigation because of underestimation.

26 August 2023 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
YYYuzo Yamasaki
Yuzo Yamasaki
TKTakeshi Kamitani
Takeshi Kamitani
KSKoji Sagiyama
Koji Sagiyama
THTakuya Hino
Takuya Hino
MKMegumi Kisanuki
Megumi Kisanuki
KIKousei Ishigami
Kousei Ishigami
Dynamic chest radiography (DCR) is a novel functional radiographic imaging technique that can be used to visualize pulmonary perfusion without using contrast media. Although it has many advantages and clinical utility, most radiologists are unfamiliar with this technique because of its novelty. This review aims to (1) explain the basic principles of lung perfusion assessment using DCR, (2) discuss the advantages of DCR over other imaging modalities, and (3) review multiple specific clinical applications of DCR for pulmonary vascular diseases and compare them with other imaging modalities.

28 December 2023 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MKMasateru Kawakubo
Masateru Kawakubo
MNMichinobu Nagao
Michinobu Nagao
YKYoko Kaimoto
Yoko Kaimoto
RNRisako Nakao
Risako Nakao
AYAtsushi Yamamoto
Atsushi Yamamoto
SSShuji Sakai
Shuji Sakai
Objective: Deep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECTSPT) against PET in 17 segments according to the American Heart Association (AHA). Methods: This retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECTSPT generation model was trained (stress: 979 image pairs, rest: 987 image pairs) and validated (stress: 421 image pairs, rest: 425 image pairs) using 31 cases of SPECT and PET image pairs using an image-to-image translation network. Forty of 71 cases of left ventricular base-to-apex short-axis images were translated to SPECTSPT in the stress and resting state (stress: 1830 images, rest: 1856 images). Representative voxel values of SPECT and SPECTSPT in the 17 AHA segments against PET were compared. The stress, resting, and difference scores of 40 cases of SPECT and SPECTSPT were also compared in each of the 17 segments. Results: For AHA 17-segment-wise analysis, stressed SPECT but not SPECTSPT voxel values showed significant error from PET at basal anterior regions (segments #1, #6), and at mid inferoseptal regions (segments #8, #9, and #10). SPECT, but not SPECTSPT, voxel values at resting state showed significant error at basal anterior regions (segments #1, #2, and #6), and at mid inferior regions (segments #8, #9, and #11). Significant SPECT overscoring was observed against PET in basal-to-apical inferior regions (segments #4, #10, and #15) during stress. No significant overscoring was observed in SPECTSPT at stress, and only moderate over and underscoring in the basal inferior region (segment #4) was found in the resting and difference states. Conclusions: Our PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECTSPT generation model may be applied as a low-cost and practical clinical tool that provides powerful auxiliary information for the diagnosis of myocardial blood flow.

30 December 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
MKMasateru Kawakubo
Masateru Kawakubo
HWHiroto Waki
Hiroto Waki
TSTakashi Shirasaka
Takashi Shirasaka
TKTsukasa Kojima
Tsukasa Kojima
RMRyoji Mikayama
Ryoji Mikayama
KIKousei Ishigami
Kousei Ishigami