View All Publications
11 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
JCJoan Lambert Cause
Joan Lambert Cause
BEBaciu Vlad Eusebiu
Baciu Vlad Eusebiu
Bruno da SilvaBruno da Silva
Bruno da Silva
JNJuan Carlos García Naranjo
Juan Carlos García Naranjo
JSJohan Stiens
Johan Stiens
The grown interest in healthcare applications has made biomedical engineering one of the fastest growing disciplines in recent years. Photoplethysmography (PPG) has gained popularity in recent years due to its versatility for noninvasive monitoring of vital signs such as heart rate, respiratory rate, blood oxygen saturation and blood pressure. In this work, an adjustable PPG-based educational device called PPG EduKit, which aims to facilitate the learning of the PPG technology for a wide range of engineering and medical disciplines is proposed. Through the use of this educational platform, the PPG signal can be understood, modified and implemented along with the extraction of its relevant physiological information from a didactic, intuitive and practical way. The PPG Edukit is evaluated for the extraction of physiological parameters such as heart rate and blood oxygen level, demonstrating how its features contribute to engineering and medical students to assimilate technical concepts in electrical circuits, biomedical instrumentation, and human physiology.

29 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJoan Lambert Cause
Joan Lambert Cause
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
JNJuan Carlos García Naranjo
Juan Carlos García Naranjo
JSJohan Stiens
Johan Stiens
Bruno da SilvaBruno da Silva
Bruno da Silva
Photoplethysmography (PPG) is widely used to assess cardiovascular health. Yet, its effectiveness is often hindered by external factors like contact force (CF), which significantly affects the accuracy and reliability of measurements. This study investigates how variations in the CF at the index fingertips influence six signal quality indices (SQIs)—including the perfusion index, skewness, kurtosis, entropy, zero-crossing rate, and relative power—using data from 11 healthy participants. Our analysis of normalized CF values reveals that lower CF ranges (0.2 to 0.4) may be optimal for extracting information about perfusion and blood flow. However, they may not be the best range to capture all the physiological details within the PPG pulse. In contrast, higher CF ranges (0.4 to 0.6) enable capturing more complex signals that could be physiologically representative. The findings underscore the necessity of considering viscoelastic tissue properties and individual biomechanical differences, advocating for both the normalization of CF for improved cross-subject comparison and personalized CF calibration to adapt PPG devices to diverse populations. These strategies ensure measurement reliability and consistency, thereby advancing the accuracy of cardiac and vascular assessments. Our study offers guidelines for adjusting the CF levels to balance signal detail and perfusion quality, customized to meet specific analytical requirements, with direct implications for both clinical and research environments.

24 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JCJoan Lambert Cause
Joan Lambert Cause
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
Bruno da SilvaBruno da Silva
Bruno da Silva
JNJuan Carlos García Naranjo
Juan Carlos García Naranjo
JSJohan Stiens
Johan Stiens
Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.

24 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JCJoan Lambert Cause
Joan Lambert Cause
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
Bruno da SilvaBruno da Silva
Bruno da Silva
JNJuan Carlos García Naranjo
Juan Carlos García Naranjo
JSJohan Stiens
Johan Stiens
Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.

4 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BEBaciu Vlad Eusebiu
Baciu Vlad Eusebiu
JCJoan Lambert Cause
Joan Lambert Cause
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
JNJuan Carlos García Naranjo
Juan Carlos García Naranjo
JSJohan Stiens
Johan Stiens
Bruno da SilvaBruno da Silva
Bruno da Silva
Over the past few years, there has been increased interest in photoplethysmography (PPG) technology, which has revealed that, in addition to heart rate and oxygen saturation, the pulse shape of the PPG signal contains much more valuable information. Lately, the wearable market has shifted towards a multi-wavelength and multichannel approach to increase signal robustness and facilitate the extraction of other intrinsic information from the signal. This transition presents several challenges related to complexity, accuracy, and reliability of algorithms. To address these challenges, anomaly detection stages can be employed to increase the accuracy and reliability of estimated parameters. Powerful algorithms, such as lightweight machine learning (ML) algorithms, can be used for anomaly detection in multi-wavelength PPG (MW-PPG). The main contributions of this paper are (a) proposing a set of features with high information gain for anomaly detection in MW-PPG signals in the classification context, (b) assessing the impact of window size and evaluating various lightweight ML models to achieve highly accurate anomaly detection, and (c) examining the effectiveness of MW-PPG signals in detecting artifacts.

27 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Angel Solé MorilloAngel Solé Morillo
Angel Solé Morillo
JCJoan Lambert Cause
Joan Lambert Cause
KPKevin De Pauw
Kevin De Pauw
Bruno da SilvaBruno da Silva
Bruno da Silva
JSJohan Stiens
Johan Stiens
Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source–detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance. The coefficient of variation (CV) is proposed as a new signal quality index (SQI) to evaluate signal variabilities. This study first characterizes the PPG system, which is then used to acquire PPG signals in the chest of 14 healthy participants. Results show a great DC variability at 6 mm, homogenizing at 9 and 12 mm. This suggests that PPG systems are also sensitive to the near- and far-field effects commonly reported and studied in optics, which can impact the accuracy of physiological parameters dependent on the DC component, such as oxygen saturation (SpO2).