Aim. To compare implant survival rate and marginal bone loss (MBL) of immediately loaded single implants inserted by using ultrasonic implant site preparation (UISP) (test) and conventional rotary instrumentation (control). Methods. Two single implants were inserted for each patient: after randomization, test site was prepared by using an ultrasonic device (Piezosurgery Touch, Mectron, Italy) and control site was prepared by using the drills of the selected implant system (Premium AZT, Sweden & Martina, Italy), until reaching a final diameter of 3 mm in both groups. Identical implants (3.8x11.5 mm) were inserted in all sites at crestal level. Impressions were taken and screwed resin single crowns with platform-switched provisional abutments were delivered with 48 hours. Periapical radiographs were taken at provisional crown insertion (T0), 6 months (T1) and one year (T2) after prosthetic loading to measure MBL. All data were tested for normality and subsequently analyzed by paired samples t-test and forward multiple linear regression. Results. Forty-eight patients were treated in six centers with the insertion of ninety-six implants (48 test; 48 control). Four implants in four patients failed within the first six months of healing (two in test group; two in control group; no difference between groups). Forty patients (age 60.1±10.7 years; 22 female, 18 male) were included in the final analysis. Mean MBL after six months of loading was 1.39±1.03 mm in the test group and 1.42±1.16 mm in the control group (p>0.05) and after one year was 1.92±1.14 mm and 2.14±1.55 mm in test and control, respectively (p>0.05). Conclusions. No differences in survival rate and MBL were demonstrated between UISP and conventional site preparation with rotary instruments in immediately loaded dental implants: UISP, with its characteristics of enhanced surgical control and safety in proximity of delicate structures, may be used as a reliable alternative to the traditional drilling systems.
Background: The surgical dental treatment of subjects admitted for anticoagulants therapy represents a consistent risk for peri-operative bleeding. The aim of the present study was to investigate the clinical findings of dental surgery operative management of the patients under anticoagulants drugs protocol. Methods: The literature screening was performed using Pubmed/Medline, EMBASE and Cochrane library, considering only randomized clinical trials (RCTs) papers. No limitations about the publication’s period, follow-up time or clinical parameters were considered. Results: A total of eight RCTs were included for the qualitative synthesis. No thromboembolic complications were reported in any studies. Several bleeding episodes associated with anticoagulant drugs in dental surgery were mild and generally happened on the first day after the treatment. Conclusions: The use of local haemostatic measures is generally effective for bleeding control with no further pharmacological drug management or suspension.
Background: To compare the influence of different temperatures and curvature radii on the cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC) single file nickel-titanium rotary instruments. Methods: A total of 120 instruments of F6ST and OC #25.06 were evaluated in 5 mm and 3 mm curvature radii at two temperatures (20 °C ± 1 °C and 37 °C ± 1 °C) in 16 mm stainless steel artificial canals associated with a curvature of 60°. The cyclic fatigue of tested files was assessed by employing a customized testing apparatus and expressed as times to fracture (TtF). A statistical analysis was performed with the significance level set at 95%. Results: All instruments decreased their TtF at 37 °C except for OC in the 3 mm radius, in which no significant difference was detected between 20 °C and 37 °C. A 3 mm curvature radius negatively affected TtF of all tested instruments, except for F6ST at 20 °C. F6ST had higher TtF than OC in the 3 mm radius at 20 °C, with no significant difference between them in the other tested conditions. Conclusions: Under the limits of the present in vitro study, body temperature impaired cyclic fatigue resistance of all files, except for OC in the 3 mm curvature radius. All instruments exhibited lower times to fracture in the 3 mm radius, excluding F6ST at 20 °C.
Tribology is the discipline concerning the application of friction, lubrication, and wear concepts of interacting surfaces in relative motion. A growing interest has developed in tribology application in medical biomaterials, such as resin composites used in restorative dentistry. Yet, the keywords “tribology” and “biotribology” are little applied in the pertinent publications. The aim of this scoping review was to offer an overview of tribology application in dental composites research and to identify knowledge gaps and address future research. A literature search was conducted on Pubmed and Scopus databases and the studies investigating the tribological behavior of resin composites were included for qualitative synthesis. The majority of studies on dental tribology were published in the research areas of mechanical engineering/nanotechnology and differed in several methodological aspects. The preponderant engineering approach and the lack of standardized testing make the laboratory findings poorly informative for clinicians. Future research should focus on the tribological behavior of dental materials composites by means of an integrated approach, i.e., engineering and clinical, for improving development and advancement in this field of research.