John David Thompson

Dr. John David Thompson

University Hospitals of Morecambe Bay NHS Foundation Trust, Kendal, Cumbria, UK
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

2 September 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AMAmit Mistry
Amit Mistry
Cemal UcerCemal Ucer
Cemal Ucer
John David ThompsonJohn David Thompson
John David Thompson
Rabia Sannam KhanRabia Sannam Khan
Rabia Sannam Khan
Emina K. SherEmina K. Sher
Emina K. Sher
FSF Sher
F Sher
An increase in the number of implants placed has led to a corresponding increase in the number of complications reported. The complications can vary from restorative complications due to poor placement to damage to collateral structures such as nerves and adjacent teeth. A large majority of these complications can be avoided if the implant has been placed accurately in the optimal position. Therefore, the aim of this in vitro pilot study was to investigate the effect of freehand (FH) and fully guided (FG) surgery on the accuracy of implants placed in close proximity to vital structures such as the inferior alveolar nerve (IAN). Cone-beam computed tomography (CBCT) and intraoral scans of six patients who have had previous dental implants in the posterior mandible were used in this study. The ideal implant position was planned. FG surgical guides were manufactured for each case. In this study, the three-dimensional 3D printed resin models of each of the cases were produced and the implants placed using FG and FH methods on the respective models. The outcome variables of the study, angular deviations were calculated and the distance to the IAN was measured. The mean deviations for the planned position observed were 1.10 mm coronally, 1.88 mm apically with up to 6.3 degrees’ angular deviation for FH surgery. For FG surgical technique the mean deviation was found to be at 0.35 mm coronally, 0.43 mm apically with 0.78 degrees angularly respectively. The maximum deviation from the planned position for the apex of the implant to the IAN was 2.55 mm using FH and 0.63 mm FG. This bench study, within its limitations, demonstrated surgically acceptable accuracy for both FH and FG techniques that would allow safe placement of implants to vital structures such as the IAN when a safety zone of 3 mm is allowed. Nevertheless, a better margin of error was observed for FG surgery with respect to the angular deviation and controlling the distance of the implant to the IAN using R2 Gate® system.

16 June 2017 in British Journal of Radiology
Verified
Journal Article
Closed access
AAAhmed K Abdullah
Ahmed K Abdullah
JKJudith Kelly
Judith Kelly
John David ThompsonJohn David Thompson
John David Thompson
CMClaire Mercer
Claire Mercer
RARob Aspin
Rob Aspin
PHPeter Hogg
Peter Hogg
Objective: Motion blur is a known phenomenon in full-field digital mammography, but the impact on lesion detection is unknown. This is the first study to investigate detection performance with varying magnitudes of simulated motion blur. Methods: 7 observers (15 ± 5 years' reporting experience) evaluated 248 cases (62 containing malignant masses, 62 containing malignant microcalcifications and 124 normal cases) for 3 conditions: no blurring (0 mm) and 2 magnitudes of simulated blurring (0.7 and 1.5 mm). Abnormal cases were biopsy proven. Mathematical simulation was used to provide a pixel shift in order to simulate motion blur. A free-response observer study was conducted to compare lesion detection performance for the three conditions. The equally weighted jackknife alternative free-response receiver operating characteristic was used as the figure of merit. Test alpha was set at 0.05 to control probability of Type I error. Results: The equally weighted jackknife alternative free-response receiver operating characteristic analysis found a statistically significant difference in lesion detection performance for both masses [F(2,22) = 6.01, p = 0.0084] and microcalcifications [F(2,49) = 23.14, p < 0.0001]. The figures of merit reduced as the magnitude of simulated blurring increased. Statistical differences were found between some of the pairs investigated for the detection of masses (0.0 vs 0.7 and 0.0 vs 1.5 mm) and all pairs for microcalcifications (0.0 vs 0.7, 0.0 vs 1.5 and 0.7 vs 1.5 mm). No difference was detected between 0.7 and 1.5 mm for masses. Conclusion: The mathematical simulation of motion blur caused a statistically significant reduction in lesion detection performance. These false-negative decisions could have implications for clinical practice. Advances in knowledge: This research demonstrates for the first time that motion blur has a negative and statistically significant impact on lesion detection performance in digital mammography.

1 November 2020 in Radiography
Verified
Journal Article
Closed access
SPS. Papathanasiou
S. Papathanasiou
LWL.A. Walton
L.A. Walton
John David ThompsonJohn David Thompson
John David Thompson