Gokhan Tunc

Dr. Gokhan Tunc

Atilim University, Ankara, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
HMHalit Cenan Mertol
Halit Cenan Mertol
Gokhan TuncGokhan Tunc
Gokhan Tunc
TATolga Akış
Tolga Akış
YKYunus Kantekin
Yunus Kantekin
İAİshak Can Aydın
İshak Can Aydın
Two major earthquakes struck Pazarcık and Elbistan, towns in Kahramanmaraş, Türkiye, on 6 February 2023, approximately 9 h apart. The first earthquake, recorded at 04:17 local time, had a Mw = 7.7, with a focal depth of 8.6 km. At 13:24 local time, a second earthquake occurred with Mw = 7.6 at a focal depth of 7 km, approximately 90 km north of the first one. A total of 11 provinces were severely affected by these earthquakes. As of 15 April 2023, they caused close to 51,000 deaths and almost 215,000 completely destroyed/severely damaged buildings. At some locations, the largest horizontal peak ground acceleration (PGA) values of the first and second earthquakes exceeded the code-generated PGAs by almost 3 and 1.75 times, respectively. A technical team visited these areas within 15 h of the first earthquake. The purpose of this article is to present their observations, findings, and the characteristics of the two earthquakes, with comprehensive site survey results supported by photographs. This study concludes that most of the collapsed and severely/moderately damaged buildings in the region were built between 1975 and 2000, when site inspections were rare or non-existent. In addition to the high PGAs recorded in these earthquakes, it was verified that the design and construction of these buildings did not fully comply with the earthquake codes valid at the time. The collapsed buildings and their damage patterns confirm inadequate development length, violation of bending stirrup ends at 135°, deficiencies in construction materials and reinforcement configuration, noncompliance with confinement zones, violation of the strong beam-stronger column analogy, and issues related to building inspection. Based on the extent of the damage, it is strongly recommended that the structural performance inspection of all other buildings located near major fault lines, specifically those constructed between 1975 and 2000, should be completed. Since these earthquakes generated much higher PGAs, which is believed to be one of the main reasons for the extensive damage, a re-evaluation of all other PGAs along major fault lines is also recommended.

1 February 2004 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
BSBahram M. Shahrooz
Bahram M. Shahrooz
JDJeremy T. Deason
Jeremy T. Deason
Gokhan TuncGokhan Tunc
Gokhan Tunc
A key factor behind successful performance of outrigger beam–core wall connections in hybrid structures is the adequacy of headed studs that are typically used to connect a stud plate, onto which the outrigger beam is connected through a shear tab, to the wall. In an effort to better understand cyclic behavior of stud groups under combined action of gravity shear and cyclic diaphragm forces, the research reported was undertaken. Six 1/3-scale subassemblies that involve a portion of the wall, connection, and outrigger beam were fabricated and tested. The test results suggest that a design method which closely follows available equations for computing stud capacity results in connections that reach the design loads; however, the mode of failure is stud pullout. This mode of failure does not have any ductility and lacks energy dissipation capabilities. Moreover, the available design equations fail to capture the substantial increase in strength due to wall boundary element reinforcement around the studs. The boundary element also alters the mode of failure from stud pullout to stud fracture. A new design technique based on dissipating the input energy through yielding and eventual fracture of the shear tab was developed. The performance of a test specimen designed based on this methodology was found to be satisfactory in terms of strength, ductility, and energy dissipation characteristics. Two simple adjustments to available equations were also identified to account for the effects of confinement, by wall boundary element reinforcement, around headed studs.

1 February 2004 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
BSBahram M. Shahrooz
Bahram M. Shahrooz
Gokhan TuncGokhan Tunc
Gokhan Tunc
JDJeremy T. Deason
Jeremy T. Deason
Adequate strength of headed studs under cyclic loads is a prerequisite for satisfactory performance of outrigger beam–core wall connections that commonly use multiple headed studs. Previous studies have typically not investigated the effects of reinforcement around studs, and have not accounted for the effects of cracking, damage, and yielding of reinforcement on the strength of studs. To remedy these deficiencies, two 1/4-scale subassemblies that contain a cantilever wall and two outrigger beams with and without floor diaphragms were subjected to cyclic loading. The wall reinforcement around the connection was selected according to the anticipated level of cracking and plastic hinge formation. The design methodology followed in this research resulted in connections that could develop and exceed the design forces despite extensive cracking and yielding of wall reinforcement around the headed studs. The presence of heavily confined wall boundary elements around headed studs increases the capacity. Simple methods to account for the influence of cracks and strengthening effects of boundary elements were developed. The resulting analytical model was able to accurately establish the expected mode of failure and capacity of outrigger beam–wall connections. For the outrigger beam–wall connection detail selected, the outrigger beam was found to transfer the majority of diaphragm forces directly to the core wall with negligible participation by the floor. Therefore, floor slab–wall connections can be based on simple details that resist only gravity loads unless the connections are specifically designed to transfer the diaphragm forces to the wall.

1 April 2001 in Progress in Structural Engineering and Materials
Verified
Journal Article
Closed access
PDF file
BSBahram M Shahrooz
Bahram M Shahrooz
BGBingnian Gong
Bingnian Gong
Gokhan TuncGokhan Tunc
Gokhan Tunc
JDJeremy T Deason
Jeremy T Deason

30 May 2021 in Afet ve Risk Dergisi
Verified
Journal Article
Open access
PDF file
MAMerşa ARAL
Merşa ARAL
Gokhan TuncGokhan Tunc
Gokhan Tunc
Türkiye tektonik konumu itibariyle yıkıcı etkileri olan büyük magnitüdlü depremleri üretebilen fay hatlarına sahip aktif bir deprem kuşağı üzerinde yer almaktadır. Bu konumu itibarı ile ülke her an deprem tehlikesiyle karşı karşıyadır. Depremlerin yer ve zaman ile ilgili özelliklerinin tahmin edilemez oluşu, insanların bu tür bir doğal afete konutlarında veya çalışma ortamında yakalanma ihtimallerini de yüksek riskli hale getirmektedir. Bu yüzden zaman geçirilen mekânı temsil eden binaların ve yapıların deprem sırasında veya sonrasındaki performansları önemli bir değerlendirme kriteri haline gelmektedir. Bu çalışmada, konutlar özelinde gerekli inceleme ve değerlendirmeler yapılarak kullanıcının (tüketicinin) mekânın yapısal sağlamlığına yönelik endişeleri ve beklentileri ele alınacaktır. Dolayısı ile yaşam alanını tarifleyen binaların teknik özellikleri ile depreme dayanıklılık durumuna ait bilgilerin tüketiciye nasıl ulaşacağı bu çalışmanın özünü teşkil edecektir. Bu kapsam dâhilinde binalar için kimlik bilgisi oluşturulmasına yönelik altyapı çalışması hakkında detaylı bilgiler verilecek, gerekli görüş ve önerilerde bulunulacaktır. Bu öneriler doğrultusunda bilinçli tüketici kitlesinin oluşumu hedeflenerek depremin yaratabileceği yıkıcı etkiler ve can kaybının en az düzeyde gerçekleşmesi sağlanmış olacaktır.

1 October 2021 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
PDF file
HMHalit Cenan Mertol
Halit Cenan Mertol
Gokhan TuncGokhan Tunc
Gokhan Tunc
TATolga Akis
Tolga Akis
An earthquake with a magnitude of Mw=6.8 and a depth of approximately 8.06 km occurred on January 24, 2020, with the epicenter near the town of Sivrice in Elazığ province, Turkey. The earthquake resulted in numerous collapses and severe structural damage to the buildings located in the downtowns and villages of Elazığ and Malatya provinces. A technical team investigated the earthquake-affected areas, and this study presents their observations and findings with respect to reinforced concrete buildings. It was concluded that almost all of the collapsed or severely-damaged reinforced concrete buildings were constructed between 1975 and 1998. The design and construction of these buildings did not comply with the specifications of the Turkish earthquake codes valid at that time. The failures and severe damage of the buildings are associated with poor material quality, inadequate reinforcement configuration, and framing problems related to their lateral load-carrying systems. Therefore, it is recommended that buildings constructed between 1975 and 1998 in the region be structurally re-evaluated to avoid additional loss of life and property in future earthquakes.