Solvent-assisted grinding (SAG) and solution slow evaporation (SSE) methods are generally used for the preparation of cocrystals. However, even by using the same solvent, active pharmaceutical ingredient (API), and cocrystal coformer (CCF), the cocrystals prepared using the two methods above are sometimes inconsistent. In the present study, in the cocrystal synthesis of praziquantel (PRA) with polyhydroxy phenolic acid, including protocatechuic acid (PA), gallic acid (GA), and ferulic acid (FA), five different cocrystals were prepared using SAG and SSE. Three of the cocrystals prepared using the SAG method have the structural characteristics of carboxylic acid dimer, and two cocrystals prepared using the SSE method formed cocrystal solvates with the structural characteristics of carboxylic acid monomer. For phenolic acids containing only one phenolic hydroxyl group (ferulic acid), when preparing cocrystals with PRA by using SAG and SSE, the same product was obtained. In addition, the weak molecular interactions that were observed in the cocrystal are explained at the molecular level by using theoretical calculation methods. Finally, the in vitro solubility of cocrystals without crystal solvents and in vivo bioavailability of PRA-FA were evaluated to further understand the influence on the physicochemical properties of API for the introduction of CCF.
At present, there are many kinds of wearable ECG devices in the market, but there are many problems such as large volume, low precision, high power consumption, and discomfort in wearing. The wearable ECG monitoring system is designed, which be small, deformable, comfortable to wear, and can continuously measure ECG signals in real-time. In this paper, STM32F411 is used as the microcontroller. Furthermore, TI's 24-bit ADS1292R is used as the acquisition module of the ECG signals. The measured ECG signals are passed through a 0.5-70Hz band-pass and 50Hz notch digital filter to remove motion noise signals. The processed ECG data are stored in a Micro-SD card. At the same time, the data are sent to the upper computer (Labview) through Bluetooth to display the ECG waveform and heart rate in real-time. The device was used to measure the ECG signals of people of different ages and genders under other exercise states. The results show that the device has the advantages of comfortable wearing and low power consumption. It can display the electrocardiogram and heart rate in real-time. The ECG data transmission delay does not exceed 0.5s, and the accuracy of heart rate measurement is 92.45%.