Bessam Abdulrazak

Prof. Bessam Abdulrazak

Université de Sherbrooke, Sherbrooke, Quebec, Canada
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2019 in Health Information Science and Systems
Verified
Journal Article
Closed access
PDF file
Ibrahim SadekIbrahim Sadek
Ibrahim Sadek
JBJit Biswas
Jit Biswas
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak

15 December 2017 in IEEE Access
Verified
Journal Article
Open access
Ibrahim SadekIbrahim Sadek
Ibrahim Sadek
ESEdwin Seet
Edwin Seet
JBJit Biswas
Jit Biswas
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak
MMMounir Mokhtari
Mounir Mokhtari
Sleep is a fundamental and vital physiological function. Getting enough quality sleep is necessary to a person's mental health, physiological well-being, quality of life, and safety. Sleep-disordered breathing, specifically obstructive sleep apnea can result in serious health issues, including hypertension and stroke. The current approaches for diagnosing sleep disorders are burdensome, intrusive, and can affect the patient's sleep quality. As a result, there is a crucial need for less cumbersome systems to diagnose sleep-related problems. In this paper, we evaluated the capacity of the microbend fiber optic sensor to monitor heart rate and respiration in a nonintrusive manner. In addition, we tested the capacity of the sensor in discriminating between shallow breathing and no breathing. The proposed sensor was compared with the three-channel portable monitoring device (ApneaLink) in a clinical setting during a drug-induced sleep endoscopy. Across all ten patients recruited for our study, the system achieved satisfactory results in the mean heart rate and the mean respiratory rate with an error of 0.55 ± 0.59 beats/minute and 0.38 ± 0.32 breaths/minute, respectively. Besides, the Pearson correlation coefficient between the proposed sensor and the reference device was 0.96 and 0.78 for heart rate and respiration, respectively. On the contrary, the proposed sensor provided a very low sensitivity (24.24 ± 12.81%) and a relatively high specificity (85.88 ± 6.01%) for sleep apnea detection. It is expected that this preliminary research will pave the way toward unobtrusive detection of vital signs in real time.

18 September 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Ibrahim SadekIbrahim Sadek
Ibrahim Sadek
THTerry Tan Soon Heng
Terry Tan Soon Heng
Edwin SeetEdwin Seet
Edwin Seet
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak
Background: At present, there is an increased demand for accurate and personalized patient monitoring because of the various challenges facing health care systems. For instance, rising costs and lack of physicians are two serious problems affecting the patient’s care. Nonintrusive monitoring of vital signs is a potential solution to close current gaps in patient monitoring. As an example, bed-embedded ballistocardiogram (BCG) sensors can help physicians identify cardiac arrhythmia and obstructive sleep apnea (OSA) nonintrusively without interfering with the patient’s everyday activities. Detecting OSA using BCG sensors is gaining popularity among researchers because of its simple installation and accessibility, that is, their nonwearable nature. In the field of nonintrusive vital sign monitoring, a microbend fiber optic sensor (MFOS), among other sensors, has proven to be suitable. Nevertheless, few studies have examined apnea detection. Objective: This study aims to assess the capabilities of an MFOS for nonintrusive vital signs and sleep apnea detection during an in-lab sleep study. Data were collected from patients with sleep apnea in the sleep laboratory at Khoo Teck Puat Hospital. Methods: In total, 10 participants underwent full polysomnography (PSG), and the MFOS was placed under the patient’s mattress for BCG data collection. The apneic event detection algorithm was evaluated against the manually scored events obtained from the PSG study on a minute-by-minute basis. Furthermore, normalized mean absolute error (NMAE), normalized root mean square error (NRMSE), and mean absolute percentage error (MAPE) were employed to evaluate the sensor capabilities for vital sign detection, comprising heart rate (HR) and respiratory rate (RR). Vital signs were evaluated based on a 30-second time window, with an overlap of 15 seconds. In this study, electrocardiogram and thoracic effort signals were used as references to estimate the performance of the proposed vital sign detection algorithms. Results: For the 10 patients recruited for the study, the proposed system achieved reasonable results compared with PSG for sleep apnea detection, such as an accuracy of 49.96% (SD 6.39), a sensitivity of 57.07% (SD 12.63), and a specificity of 45.26% (SD 9.51). In addition, the system achieved close results for HR and RR estimation, such as an NMAE of 5.42% (SD 0.57), an NRMSE of 6.54% (SD 0.56), and an MAPE of 5.41% (SD 0.58) for HR, whereas an NMAE of 11.42% (SD 2.62), an NRMSE of 13.85% (SD 2.78), and an MAPE of 11.60% (SD 2.84) for RR. Conclusions: Overall, the recommended system produced reasonably good results for apneic event detection, considering the fact that we are using a single-channel BCG sensor. Conversely, satisfactory results were obtained for vital sign detection when compared with the PSG outcomes. These results provide preliminary support for the potential use of the MFOS for sleep apnea detection.

1 October 2022 in Computer Methods and Programs in Biomedicine Update
Verified
Journal Article
Open access
Ibrahim SadekIbrahim Sadek
Ibrahim Sadek
JCJosué Codjo
Josué Codjo
SRShafiq Ul Rehman
Shafiq Ul Rehman
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak

1 January 2010 in International Journal of Web and Grid Services
Verified
Journal Article
Closed access
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak
BCBelkacem Chikhaoui
Belkacem Chikhaoui
CGCharles Gouin-Vallerand
Charles Gouin-Vallerand
BFBenoit Fraikin
Benoit Fraikin
This paper presents a universal ontology for smart environments aiming to overcome the limitations of the existing ontologies. We enrich our ontology by adding new environmental aspects such as the referentiality and environmental change, that can be used to describe domains as well as applications. We show through a case study how our ontology is used and integrated in a self-organising middleware for smart environments.

1 September 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
Ibrahim SadekIbrahim Sadek
Ibrahim Sadek
Bessam AbdulrazakBessam Abdulrazak
Bessam Abdulrazak