Christoph Seger

Dr. Christoph Seger

Labordiagnostic St. Gallen West AG, St. Gallen, Switzerland
orcid
CMO @ labordiagnostic.ch

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
MBMercè Brunet
Mercè Brunet
TGTeun van Gelder
Teun van Gelder
AÅAnders Åsberg
Anders Åsberg
VHVincent Haufroid
Vincent Haufroid
DHDennis A. Hesselink
Dennis A. Hesselink
SBStein Bergan
Stein Bergan
Ten years ago, a consensus report on the optimization of tacrolimus was published in this journal. In 2017, the Immunosuppressive Drugs Scientific Committee of the International Association of Therapeutic Drug Monitoring and Clinical Toxicity (IATDMCT) decided to issue an updated consensus report considering the most relevant advances in tacrolimus pharmacokinetics (PK), pharmacogenetics (PG), pharmacodynamics, and immunologic biomarkers, with the aim to provide analytical and drug-exposure recommendations to assist TDM professionals and clinicians to individualize tacrolimus TDM and treatment. The consensus is based on in-depth literature searches regarding each topic that is addressed in this document. Thirty-seven international experts in the field of TDM of tacrolimus as well as its PG and biomarkers contributed to the drafting of sections most relevant for their expertise. Whenever applicable, the quality of evidence and the strength of recommendations were graded according to a published grading guide. After iterated editing, the final version of the complete document was approved by all authors. For each category of solid organ and stem cell transplantation, the current state of PK monitoring is discussed and the specific targets of tacrolimus trough concentrations (predose sample C0) are presented for subgroups of patients along with the grading of these recommendations. In addition, tacrolimus area under the concentration–time curve determination is proposed as the best TDM option early after transplantation, at the time of immunosuppression minimization, for special populations, and specific clinical situations. For indications other than transplantation, the potentially effective tacrolimus concentrations in systemic treatment are discussed without formal grading. The importance of consistency, calibration, proficiency testing, and the requirement for standardization and need for traceability and reference materials is highlighted. The status for alternative approaches for tacrolimus TDM is presented including dried blood spots, volumetric absorptive microsampling, and the development of intracellular measurements of tacrolimus. The association betweenCYP3A5genotype and tacrolimus dose requirement is consistent (Grading A I). So far, pharmacodynamic and immunologic biomarkers have not entered routine monitoring, but determination of residual nuclear factor of activated T cells–regulated gene expression supports the identification of renal transplant recipients at risk of rejection, infections, and malignancy (B II). In addition, monitoring intracellular T-cell IFN-g production can help to identify kidney and liver transplant recipients at high risk of acute rejection (B II) and select good candidates for immunosuppression minimization (B II). Although cell-free DNA seems a promising biomarker of acute donor injury and to assess the minimally effective C0of tacrolimus, multicenter prospective interventional studies are required to better evaluate its clinical utility in solid organ transplantation. Population PK models includingCYP3A5andCYP3A4genotypes will be considered to guide initial tacrolimus dosing. Future studies should investigate the clinical benefit of time-to-event models to better evaluate biomarkers as predictive of personal response, the risk of rejection, and graft outcome. The Expert Committee concludes that considerable advances in the different fields of tacrolimus monitoring have been achieved during this last decade. Continued efforts should focus on the opportunities to implement in clinical routine the combination of new standardized PK approaches with PG, and valid biomarkers to further personalize tacrolimus therapy and to improve long-term outcomes for treated patients.

1 August 2020 in Clinical Biochemistry
Verified
Journal Article
Open access
CSChristoph Seger
Christoph Seger
LSLinda Salzmann
Linda Salzmann
Tandem mass spectrometry - especially in combination with liquid chromatography (LC-MS/MS) - is applied in a multitude of important diagnostic niches of laboratory medicine. It is unquestioned in its routine use and is often unreplaceable by alternative technologies. This overview illustrates the development in the past decade (2009-2019) and intends to provide insight into the current standing and future directions of the field. The instrumentation matured significantly, the applications are well understood, and the in vitro diagnostics (IVD) industry is shaping the market by providing assay kits, certified instruments, and the first laboratory automated LC-MS/MS instruments as an analytical core. In many settings the application of LC-MS/MS is still burdensome with locally lab developed test (LDT) designs relying on highly specialized staff. The current routine applications cover a wide range of analytes in therapeutic drug monitoring, endocrinology including newborn screening, and toxicology. The tasks that remain to be mastered are, for example, the quantification of proteins by means of LC-MS/MS and the transition from targeted to untargeted omics approaches relying on pattern recognition/pattern discrimination as a key technology for the establishment of diagnostic decisions.

1 August 2010 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
MVMichael Vogeser
Michael Vogeser
CSChristoph Seger
Christoph Seger
BACKGROUND: Novel mass spectrometric techniques such as atmospheric pressure ionization and tandem mass spectrometry have substantially extended the spectrum of clinical chemistry methods during the past decade. In particular, liquid chromatography tandem–mass spectrometry (LC-MS/MS) has become a standard tool in research laboratories as well as in many clinical laboratories. Although LC-MS/MS has features that suggest it has a very high analytical accuracy, potential sources of inaccuracy have recently been identified. CONTENT: The sources of inaccuracy in LC-MS/MS methods used in the routine quantification of small molecules are described and discussed. Inaccuracy of LC-MS/MS methods can be related to the process of ionization through the insource transformation of conjugate metabolites or target analytes and may also be attributable to ionization matrix effects that have a differential impact on target analytes and internal-standard compounds. Inaccuracy can also be associated with the process of ion selection, which mainly occurs when compounds from the sample matrix share mass transitions with a target analyte. In individual assays, most potential sources of inaccuracy can be controlled by sufficient LC separation–based sample workup before MS analysis. SUMMARY: LC-MS/MS methods should undergo rigorous and systematic validation before introduction into patient care.

1 June 2008 in Clinical Biochemistry
Verified
Journal Article
Closed access
MVMichael Vogeser
Michael Vogeser
CSChristoph Seger
Christoph Seger

11 May 2002 in Journal of Natural Products
Verified
Journal Article
Closed access
TPT. Pacher
T. Pacher
CSChristoph Seger
Christoph Seger
DED. Engelmeier
D. Engelmeier
SVSrunya Vajrodaya
Srunya Vajrodaya
OHO. Hofer
O. Hofer
HGH. Greger
H. Greger

1 April 2016 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
CSChristoph Seger
Christoph Seger
MSMaria Shipkova
Maria Shipkova
UCUwe Christians
Uwe Christians
EBElaine M. Billaud
Elaine M. Billaud
PWPing Wang
Ping Wang
PWPierre Wallemacq
Pierre Wallemacq
Monitoring immunosuppressive drugs (ISDs) in blood or plasma is still a key therapeutic drug monitoring (TDM) application in clinical settings. Narrow target ranges and severe side effects at drug underexposure or overexposure make accurate and precise measurements a must. This overview prepared by the Immunosuppressive Drugs Scientific Committee of the International Association of Therapeutic Drug Monitoring and Clinical Toxicology is intended to serve as a summary and guidance document describing the current state-of-the-art in the TDM of ISDs.