Kazuyuki Araki

Prof. Kazuyuki Araki

Showa University, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2013 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
JBJ Bamba
J Bamba
KAKazuyuki Araki
Kazuyuki Araki
AEA Endo
A Endo
TOT Okano
T Okano
Objectives:The SEDENTEXCT Project proposed quality assurance (QA) methods and introduced a QA image quality phantom. A new prototype was recently introduced that may be improved according to previous reports. The purpose of this study is to evaluate image quality in various protocols of three cone beam CT (CBCT) machines using the proposed QA phantom.Methods:Using three CBCT machines, nine image quality parameters, including image homogeneity (noise), uniformity, geometrical distortion, pixel intensity value, contrast resolution, spatial resolution [line pair (LP) chart, point spread function (PSF) and modulation transfer function (MTF)] and metal artefacts, were evaluated using a QA phantom proposed by SEDENTEXCT. Exposure parameters, slice thickness and field of view position changed variously, and the number of total protocols was 22.Results:Many protocols showed a uniform gray value distribution except in the minimum slice thickness image acquired using 3D Accuitomo 80 (Morita, Kyoto, Japan) and Verav...

17 November 2011 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
KAKazuyuki Araki
Kazuyuki Araki
TOTomohiro Okano
Tomohiro Okano

17 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MLMinh Luong
Minh Luong
Yasushi ShimadaYasushi Shimada
Yasushi Shimada
KAKazuyuki Araki
Kazuyuki Araki
MYMasahiro Yoshiyama
Masahiro Yoshiyama
JTJunji Tagami
Junji Tagami
Alireza  SadrAlireza Sadr
Alireza Sadr
Detecting the extent of occlusal caries is a clinically important but challenging task required for treatment decision making. The aim of this study was to assess the diagnostic power of 3D swept-source optical coherence tomography (OCT) for evaluation of occlusal caries in comparison with X-ray radiography. Extracted human molars not exhibiting American Dental Association (ADA) criteria advanced caries were mounted in a silicone block and digital dental radiographs were captured from the buccal side. Subsequently, occlusal surfaces were scanned with a prototype Yoshida Dental OCT. Thirteen examiners evaluated the presence and extent of caries on radiographs and dynamically sliced 3D OCT video images, using a 4 level scale—0: intact; 1: enamel demineralization without cavitation; 2: enamel caries with cavitation; 3: dentin caries with or without cavitation. Sensitivity, specificity and area under operating characteristic curves (Az) were statistically analyzed (α = 0.05). Reliability analysis showed an excellent agreement among the 13 examiners for both methods. The OCT presented a significantly higher sensitivity and Az value for the detection of caries compared to radiographs (p < 0.05). Radiography showed especially low sensitivity for dentin caries (0–2 versus 3). Dynamic slicing of 3D OCT volumes is a powerful adjunct tool to visual inspection to diagnose the dentin occlusal caries in vitro.

26 June 2009 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
KAKazuyuki Araki
Kazuyuki Araki
YMYukiko Matsuda
Yukiko Matsuda
KSKenji Seki
Kenji Seki
TOTomohiro Okano
Tomohiro Okano

1 May 2013 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
KAKazuyuki Araki
Kazuyuki Araki
SPS Patil
S Patil
AEA Endo
A Endo
TOT Okano
T Okano
Objectives:In the 2011 project “Safety and efficacy of a new and emerging dental X-ray modality (SEDENTEXCT)”, it was suggested that dose index (DI) and dose–area product (DAP) could be easily measured and used as diagnostic reference levels (DRLs), which would help in the management of radiation doses to patients in optimum exposure settings. Such indices could be directly related to effective dose. The purposes of this study, therefore, were to measure and calculate the DI and DAP in cone beam CT (CBCT) machines and to evaluate the correlation between the two.Methods:Dose measurements were performed on three-dimensional cone beam CT (3D-CBCT) machines [3D Accuitomo (J. Morita Mfg. Corp., Kyoto, Japan), Veraviewepocs (J. Morita Mfg. Corp.) and CS9300 (Carestream, New York, NY)] by exposing a cylindrical poly-methyl methacrylate (PMMA) phantom using a CT ionization chamber. These dose measurements were used for the calculation of Dose Indices 1 and 2, according to the methodology suggested by SEDENTEXCT. ...

18 January 2015 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
KAKazuyuki Araki
Kazuyuki Araki
MFMamiko Fujikura
Mamiko Fujikura
TSTsukasa Sano
Tsukasa Sano