Chidurala Saiprakash

Dr. Chidurala Saiprakash

Electrical and Electronics Engineering, SR University, Warangal, India
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
AMAlivarani Mohapatra
Alivarani Mohapatra
BNByamakesh Nayak
Byamakesh Nayak
SGSriparna Roy Ghatak
Sriparna Roy Ghatak

9 December 2022 in IEEE Access
Verified
Journal Article
Open access
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
AMAlivarani Mohaopatra
Alivarani Mohaopatra
BNByamakesh Nayak
Byamakesh Nayak
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
Partial shading (PS) phenomena significantly degrade the power output from the photovoltaic (PV) array. Due to the PS effect, there is a mismatch in current between the PV modules of a series-connected PV string. As a result, in-shaded module power dissipates, resulting in increased module temperature and the creation of local hotspots. To avoid the hotspot effect, bypass diodes are connected anti-parallel to the PV modules. But the activation of bypass diodes creates multiple peaks in I-V and P-V characteristics. The effect of PS can be reduced by using a suitable array configuration and the performance of the PV array gets improved. Among all the existing PV array configurations, the total cross-tied (TCT) configuration performs better under partial shading conditions (PSCs). But the disadvantage of TCT is that it has an enormous number of tie connections, creating complexity in an array configuration and, therefore, more cable losses. The main objective of this paper is to propose a novel array configuration named benzene (BZ) configuration, which eliminates the demerits of the TCT array configuration. Benzene configuration has improved performance with fewer tie connections compared to conventional tie-connected configurations such as TCT, bridge link (BL), and honeycomb (HC). The performance of the tie-connected array configurations is analyzed under different PSCs by considering the various performance parameters such as global maximum power (GMP), the voltage at maximum power (Vmp), current at maximum power (Imp), mismatch loss (ML), shading loss (SL), fill factor (FF) and performance ratio. It is observed that the proposed benzene array configuration gives better output performance, even having lower mismatch losses with a reduced amount of tie connections. Further, the effect of the bypass diode on a partially shaded PV string is investigated through MATLAB Simulation and experimental analysis.

1 February 2019
Verified
Conference Paper
Closed access
AMAlivarani Mohapatra
Alivarani Mohapatra
BNByamakesh Nayak
Byamakesh Nayak
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
Maximum power point tracking (MPPT) plays a vital role in photovoltaic (PV) system to utilize PV energy efficiently. The maximum power point (MPP) of PV system varies with atmospheric conditions and to track it, an efficient tracking system is needed. There are different MPPT algorithms available to track the maximum power. Among different MPPT techniques P&O MPPT is mostly used because of its plain structure and it is easy to implement. But conventional P&O method is slow in nature and suffers from steady state oscillations. To avoid this, this paper emphasizes on an adaptive P&O MPPT which can able to track the MPP rapidly with less steady state oscillation as compared with conventional P&O MPPT algorithm. The efficacy of the proposed method is verified considering both simulation and experimental results.

21 July 2022
Verified
Conference Paper
Closed access
S Ramana Kumar JogaS Ramana Kumar Joga
S Ramana Kumar Joga
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
AMAlivarani Mohaopatra
Alivarani Mohaopatra
PSPampa Sinha
Pampa Sinha
BNByamakesh Nayak
Byamakesh Nayak
MMM K Maharana
M K Maharana
The output power of a photovoltaic (PV) system is dependent on the perfect operation of the PV array. PV arrays may experience various fault conditions as a result of open circuit, short circuit, and partial shading. A fault is an aberrant situation that can interfere with the effective execution of a PV system. To reduce power loss and harm to the PV system, design engineers must identify faults. The most common problems in PV array systems are open circuit, partial shading, hotspots, cracks and short circuit faults. Several scientists suggested fault diagnosis methods to recognize faults in PV arrays, however the majority failed to detect problems accurately and quickly. In this paper, a two-stage algorithm based on wavelet transform and ensemble KNN method is used to detect and classify faults in PV array. A 6X6 series parallel PV array is used to test the proposed methodology. MATLAB Simulink is used to model the 6X6 PV array. Wavelet Analysis tool bar is used for signal analysis.

1 February 2020
Verified
Conference Paper
Closed access
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
AMAlivarani Mohapatra
Alivarani Mohapatra
BNByamakesh Nayak
Byamakesh Nayak
SGSriparna Roy Ghatak
Sriparna Roy Ghatak
The performance of PV array degrades due to uncertain solar irradiance characteristics. These situations become worsen at the time of partial shading (PS). Due to PS, there is a mismatch in electrical characteristics of the PV module in an array, which results in a significant reduction in PV output power. The output power reduction depends upon the amount of mismatch, which depends on factors such as array size, type of configuration and shading patterns. To reduce the partial shading effect and to improve the PV output power under different shading conditions, a modified Bridge link (BL) array configuration has been proposed in this paper. The performance of the proposed array configuration has been compared with different conventional array configuration, and its superiority has been discussed.

2 January 2021
Verified
Conference Paper
Closed access
Chidurala SaiprakashChidurala Saiprakash
Chidurala Saiprakash
AMAlivarani Mohapatra
Alivarani Mohapatra
BNByamakesh Nayak
Byamakesh Nayak
In solar photovoltaic system, partial shading condition (PSC) is one of the main obstructions in constant power generation. PSC is caused due to the passing clouds, shadows of the nearby buildings and trees, dust particles accumulated on the PV modules etc. Under PSC, PV modules experience the mismatch in power generation and exhibit the uneven PV characteristics. Partial shading effect on PV system can be reduced by choosing a suitable PV array configuration. In this paper, a new array configuration named as Alternative Tri Tie (ATT) is proposed. For performance comparison, a PV array of size 6×6 is modeled in MATLAB Simulink. Different PV configurations such as series-parallel (SP), Bridge link (BL), Total cross tied (TCT), Honey Comb (HC) and Alternative Tri Tie (ATT) are considered under various shading conditions. Performance of different array configurations are compared in terms of voltage at maximum power (V m), current at maximum power (Im), maximum power (Pm) and fill factor. It is observed that proposed array configuration outperforms the conventional array configurations.