This work proposes a mixed-integer linear programming model for the operational cost function of lithium-ion batteries that should be applied in a microgrid centralized controller. Such a controller aims to supply loads while optimizing the leveled cost of energy, and for that, the cost function of the battery must compete with the cost functions of other energy resources, such as distribution network, dispatchable generators, and renewable sources. In this paper, in order to consider the battery lifetime degradation, the proposed operational cost model is based on the variation in its state of health (SOH). This variation is determined by experimental data that relate the number of charge and discharge cycles to some of the most important factors that degrade the lifespan of lithium-ion batteries, resulting in a simple empirical model that depends on the battery dispatch power and the current state of charge (SOC). As proof-of-concept, hardware-in-the-loop (HIL) simulations of a real microgrid are performed considering a centralized controller with the proposed battery degradation cost function model. The obtained results demonstrate that the proposed cost model properly maintains the charging/discharging rates and the SOC at adequate levels, avoiding accelerating the battery degradation with use. For the different scenarios analyzed, the battery is only dispatched to avoid excess demand charges and to absorb extra power produced by the non-dispatchable resources, while the daily average SOC ranges from 48.86% to 65.87% and the final SOC converges to a value close to 50%, regardless of the initial SOC considered.
This paper presents the development of a microgrid centralized controller (MGCC) designed to work under different grid configurations and ensuring energy cost reduction and reliability in both islanded and connected modes by solving a mixed integer linear programming optimization problem containing the energy resources configured in the controller's software. The work will tackle the creation a generic controller for energy resources, as well as the mathematical model for the optimization problem and its interaction to a graphic user interface prepared for non-specialized operators. In addition, simulation and experimental results demonstrate the controller's capability to dispatch these resources rightly, always respecting the power balance within the microgrid, a feature needed for operation under islanded mode. Experimental results were taken from a test bed comprised of a real office building installed in the city of Bauru, SP, in Brazil, where the controller may dispatch energy resources to achieve its goals in a real system.
This work presents a load prioritization approach for a microgrid centralized-controller operating in islanded mode. The optimization in islanded mode aims to maximize the provision of the loads while following a list of priorities, which is set by the user. Controllable loads can be dragged within the priority list according to the user's preferences. Loads and groups of loads take priority among others according to their position on the list. In addition, the user may set preferences according to: the loads and groups of loads’ supply options; the amount of energy that must be saved as a backup during connected mode in order to being able to meet selected loads in an occasional islanded mode; and which loads should be automatically shut down in the islanded mode. We present a mathematical model to describe these options, as well as simulations and results.
This article deals with the Demand Response (DR) application on refrigeration equipment for the hotel sector, establishing strategies at various levels of aggressiveness, by taking into account the thermal comfort in the facilities. The simulations are based on DRQAT software adapted to the Brazilian scenario. The analysis consists in a comparison of the results obtained with the electricity price in the short-term market, in order to obtain an estimate of profits from DR, besides establishing a relation between the value of DR per period of application and levels of thermal comfort. In this way, the circumstances in which DR becomes viable for the hotel sector are verified. The result of this analysis indicates that, in order to provide opportunities for supplying DR with maximum efficiency of use of the resource, it is necessary to create mechanisms for load aggregation. Thus, the added flexibility becomes significant in both economic and energy terms.
In-stream hydrokinetic turbines, devices that generate electrical power from moving currents without the use of dams, have the potential to significantly impact the electrical power portfolio of many countries. This work focuses on improving the power production of in-stream hydrokinetic turbines by implementing an adaptive controller that regulates shaft torque. This controller is evaluated using a numerical rotor simulation that utilizes a blade element momentum approach with a dynamic wake in-flow model. The conducted numerical simulations demonstrate that adaptive control can effectively converge a sub-optimal controller gain to an optimal one that maximizes shaft power using only measured RPM and flow speed values.