Chao Wang

Dr. Chao Wang

Linyi University, Linyi, Shandong, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
CWChao Wang
Chao Wang
HYHao Yu
Hao Yu
QZQiang Zhao
Qiang Zhao
Aflatoxin B1 (AFB1) is one of the mycotoxins produced by Aspergillus flavus and Aspergillus parasiticus, and it causes contamination in foods and great risk to human health. Simple sensitive detection of AFB1 is important and demanded for food safety and quality control. Aptamers can specifically bind to targets with high affinity, showing advantages in affinity assays and biosensors. We reported an aptamer structure-switch for fluorescent detection of aflatoxin B1 (AFB1), using a label-free aptamer, a fluorescein (FAM)-labeled complementary strand (FDNA), and a quencher (BHQ1)-labeled complementary strand (QDNA). When AFB1 is absent, these three strands assemble into a duplex DNA structure through DNA hybridization, making FAM close to BHQ1, and fluorescence quenching occurs. In the presence of AFB1, the aptamer binds with AFB1, instead of hybridizing with QDNA. Thus, FAM is apart from BHQ1, and fluorescence increases with the addition of AFB1. This assay allowed detection of AFB1 with a detection limit of 61 pM AFB1 and a dynamic concentration range of 61 pM to 4 μM. This aptamer-based method enabled detection of AFB1 in complex sample matrix (e.g., beer and corn flour samples).


28 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
CWChao Wang
Chao Wang
KZKexiao Zhu
Kexiao Zhu
JYJie Yu
Jie Yu
PSpengfei shi
pengfei shi
This paper reported an improved molecular beacon method for the rapid detection of aflatoxin B1 (AFB1), a natural mycotoxin with severe carcinogenicity. With the assistance of a complementary DNA (cDNA) chain, the molecular beacon which consists of a DNA aptamer flanked by FAM and BHQ1 displayed a larger fluorescent response to AFB1, contributing to the sensitive detection of AFB1. Upon optimization of some key experimental factors, rapid detection of AFB1 ranging from 1 nM to 3 μM, within 20 min, was realized by using this method. A limit of detection (LoD) of 1 nM was obtained, which was lower than the LoD (8 nM) obtained without cDNA assistance. This aptamer-based molecular beacon detection method showed advantages in easy operation, rapid analysis and larger signal response. Good specificity and anti-interference ability were demonstrated. This method showed potential in real-sample analysis.

3 January 2025 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
WZWenhan Zhang
Wenhan Zhang
CWChao Wang
Chao Wang
KRKangci Ren
Kangci Ren
XSXiaoyu Song
Xiaoyu Song
QWQing Wang
Qing Wang
PSpengfei shi
pengfei shi

31 August 2023 in The Analyst
Verified
Journal Article
Closed access
PDF file
JYJie Yu
Jie Yu
SAShuheng Ai
Shuheng Ai
WZWenhan Zhang
Wenhan Zhang
CWChao Wang
Chao Wang
PSpengfei shi
pengfei shi
Based on the principle of fluorescence resonance energy transfer (FRET), a simple ratiometric fluorescent aptasensor for convenient detection of ochratoxin A (OTA), a Group IIB carcinogen secreted by some fungi, was established. Initially, the anti-OTA aptamer with a quadruplex structure was flanked with FAM and BHQ1, and its partially complementary DNA (cDNA) was tagged with Cy3. In the absence of OTA, this aptamer hybridized with the cDNA strand forming a DNA duplex structure, in which BHQ1 was adjacent to Cy3 and distant from FAM. Due to the FRET principle, the fluorescence intensity emitted by Cy3 (FCy3) was quenched by BHQ1, and the fluorescence intensity emitted by FAM (FFAM) recovered. In the presence of OTA, the prepared aptamer preferred to bind with OTA instead of cDNA, forming an aptamer–OTA complex structure in which BHQ1 was adjacent to FAM and distant from Cy3. As a result, FFAM was quenched and FCy3 was restored. OTA can be accurately detected via the determination of the FCy3/FFAM ratio value. Under optimal conditions, this ratiometric fluorescent aptasensor offers excellent OTA detection in the range of 0.6 nmol L−1–5 μmol L−1, with a limit of detection (LOD) of 0.3 nmol L−1. This ratiometric aptasensor showed the advantages of easy operation, accuracy and sensitive analysis. Good specificity of this aptasensor was demonstrated. This ratiometric aptasensor could be used for the detection of OTA in real samples, e.g. beer and orange juice, showing its promising application potential.

11 March 2026 in Analytical Biochemistry
Verified
Journal Article
Closed access
YCYalin Chang
Yalin Chang
YGYinuo Gai
Yinuo Gai
CWChao Wang
Chao Wang
PSPengfei Shi
Pengfei Shi