Rodward Lorenzo Hewlin

Dr. Rodward Lorenzo Hewlin

Engineering Technology, University of North Carolina at Charlotte, Charlotte, Michigan, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
BYBenjamin B. Yellen
Benjamin B. Yellen
RERandall M. Erb
Randall M. Erb
HSHui S. Son
Hui S. Son
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
HSHao Shang
Hao Shang
GLGil U. Lee
Gil U. Lee
A new mode of magnetophoresis is described that is capable of separating micron-sized superparamagnetic beads from complex mixtures with high sensitivity to their size and magnetic moment. This separation technique employs a translating periodic potential energy landscape to transport magnetic beads horizontally across a substrate. The potential energy landscape is created by superimposing an external, rotating magnetic field on top of the local fixed magnetic field distribution near a periodic arrangement of micro-magnets. At low driving frequencies of the external field rotation, the beads become locked into the potential energy landscape and move at the same velocity as the traveling magnetic field wave. At frequencies above a critical threshold, defined by the bead's hydrodynamic drag and magnetic moment, the motion of a specific population of magnetic beads becomes uncoupled from the potential energy landscape and its magnetophoretic mobility is dramatically reduced. By exploiting this frequency dependence, highly efficient separation of magnetic beads has been achieved, based on fractional differences in bead diameter and/or their specific attachment to two microorganisms, i.e., B. globigii and S. cerevisiae.

Verified
Journal Article
Open access
PDF file
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
JTJoseph Murphy Tindall
Joseph Murphy Tindall
This paper presents the methodology and computational results of simulated medical drug targeting (MDT) via induced magnetism intended for administering intravenous patient-specific doses of therapeutic agents in a Circle of Willis (CoW) model. The multi-physics computational model used in this work is from our previous works. The computational model is used to analyze pulsatile blood flow, particle motion, and particle capture efficiency in a magnetized region using the magnetic properties of magnetite (Fe3O4) and equations describing the magnetic forces acting on particles produced by an external cylindrical electromagnetic coil. A Eulerian–Lagrangian technique is implemented to resolve the hemodynamic flow and the motion of particles under the influence of a range of magnetic field strengths (Br = 2T, 4T, 6T, and 8T). Particle diameter sizes of 10 nm to 4 µm in diameter were assessed. Two dimensionless numbers are also investigated a priori in this study to characterize relative effects of Brownian motion (BM), magnetic force-induced particle motion, and convective blood flow on particle motion. Similar to our previous works, the computational simulations demonstrate that the greatest particle capture efficiency results for particle diameters within the micron range, specifically in regions where flow separation and vortices are at a minimum. Additionally, it was observed that the capture efficiency of particles decreases substantially with smaller particle diameters, especially in the superparamagnetic regime. The highest capture efficiency observed for superparamagnetic particles was 99% with an 8T magnetic field strength and 95% with a 2T magnetic field strength when analyzing 100 nm particles. For 10 nm particles and an 8T magnetic field strength, the particle capture efficiency was 48%, and for a 2T magnetic field strength the particle capture efficiency was 33%. Furthermore, it was found that larger magnetic field strengths, large particle diameter sizes (1 µm and above), and slower blood flow velocity increase the particle capture efficiency. The key finding in this work is that favorable capture efficiencies for superparamagnetic particles were observed in the CoW model for weak fields (Br < 4T) which demonstrates MDT as a possible viable treatment candidate for cardiovascular disease.

9 November 2017 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
JKJohn P. Kizito
John P. Kizito

21 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
MEMaegan Edwards
Maegan Edwards
CSChristopher Schultz
Christopher Schultz
The timely detection and diagnosis of diseases and accurate monitoring of specific genetic conditions require rapid and accurate separation, sorting, and direction of target cell types toward a sensor device surface. In that regard, cellular manipulation, separation, and sorting are progressively finding application potential within various bioassay applications such as medical disease diagnosis, pathogen detection, and medical testing. The aim of this paper is to present the design and development of a simple traveling wave ferro-microfluidic device and system rig purposed for the potential manipulation and magnetophoretic separation of cells in water-based ferrofluids. This paper details in full: (1) a method for tailoring cobalt ferrite nanoparticles for specific diameter size ranges (10–20 nm), (2) the development of a ferro-microfluidic device for potentially separating cells and magnetic nanoparticles, (3) the development of a water-based ferrofluid with magnetic nanoparticles and non-magnetic microparticles, and (4) the design and development of a system rig for producing the electric field within the ferro-microfluidic channel device for magnetizing and manipulating nonmagnetic particles in the ferro-microfluidic channel. The results reported in this work demonstrate a proof of concept for magnetophoretic manipulation and separation of magnetic and non-magnetic particles in a simple ferro-microfluidic device. This work is a design and proof-of-concept study. The design reported in this model is an improvement over existing magnetic excitation microfluidic system designs in that heat is efficiently removed from the circuit board to allow a range of input currents and frequencies to manipulate non-magnetic particles. Although this work did not analyze the separation of cells from magnetic particles, the results demonstrate that non-magnetic (surrogates for cellular materials) and magnetic entities can be separated and, in some cases, continuously pushed through the channel based on amperage, size, frequency, and electrode spacing. The results reported in this work establish that the developed ferro-microfluidic device may potentially be used as an effective platform for microparticle and cellular manipulation and sorting.

29 March 2019 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
ACAshley Ciero
Ashley Ciero
JKJohn P. Kizito
John P. Kizito

Verified
Journal Article
Open access
PDF file
RHRodward Lorenzo Hewlin
Rodward Lorenzo Hewlin
MEMaegan Edwards
Maegan Edwards
Cell counting and sorting is a vital step in the purification process within the area of biomedical research. It has been widely reported and accepted that the use of hydrodynamic focusing in conjunction with the application of a dielectrophoretic (DEP) force allows efficient separation of biological entities such as platelets from red blood cell (RBC) samples due to their size difference. This paper presents computational results of a multiphysics simulation modelling study on evaluating continuous separation of RBCs and platelets in a microfluidic device design with saw-tooth profile electrodes via DEP. The theoretical cell particle trajectory, particle cell counting, and particle separation distance study results reported in this work were predicted using COMSOL v6.0 Multiphysics simulation software. To validate the numerical model used in this work for the reported device design, we first developed a simple y-channel microfluidic device with square “in fluid” electrodes similar to the design reported previously in other works. We then compared the obtained simulation results for the simple y-channel device with the square in fluid electrodes to the reported experimental work done on this simple design which resulted in 98% agreement. The design reported in this work is an improvement over existing designs in that it can perform rapid separation of RBCs (estimated 99% purification) and platelets in a total time of 6–7 s at a minimum voltage setting of 1 V and at a minimum frequency of 1 Hz. The threshold for efficient separation of cells ends at 1000 kHz for a 1 V setting. The saw-tooth electrode profile appears to be an improvement over existing designs in that the sharp corners reduced the required horizontal distance needed for separation to occur and contributed to a non-uniform DEP electric field. The results of this simulation study further suggest that this DEP separation technique may potentially be applied to improve the efficiency of separation processes of biological sample scenarios and simultaneously increase the accuracy of diagnostic processes via cell counting and sorting.