COVID-19 disease is characterised by a wide range of symptoms that in most cases resemble flu or cold. Early detection of infections, monitoring of patients’ conditions, and identification of patients with worsening symptoms became crucial during the peak of pandemic. The aim of this study was to assess and compare the performance of common early warning scores at the time of admission to an emergency department in predicting in-hospital mortality in patients with COVID-19. The study was based on a retrospective analysis of patients with SARS-CoV-2 infection admitted to an emergency department between March 2020 and April 2022. The prognostic value of early warning scores in predicting in-hospital mortality was assessed using the receiver operating characteristic (ROC) curve. Patients’ median age was 59 years, and 52.33% were male. Among all the EWS we assessed, REMS had the highest overall accuracy (AUC 0.84 (0.83–0.85)) and the highest NPV (97.4%). REMS was the most accurate scoring system, characterised by the highest discriminative power and negative predictive value compared to the other analysed scoring systems. Incorporating these tools into clinical practice in a hospital emergency department could provide more effective assessment of mortality and, consequently, avoid delayed medical assistance.
The purpose of the study was to present the characteristics of Helicopter Emergency Medical Service (HEMS) and Emergency Medical Service (EMS) interventions concerning newborns in Poland. The study involved a retrospective analysis of missions by Polish Medical Air Rescue crews concerning newborns, carried out in Poland between January 2011 and December 2020. Polish Medical Air Rescue crews were most commonly dispatched to urban areas (86.83%), for patient transfer (59.67%), using an airplane (65.43%), between 7 AM and 6:59 PM (93.14%), and in the summer (28.67%). Further management involved handing over the neonatal patient to a ground neonatal ambulance team. Most of the patients studied were male (58.02%), and the most common diagnosis requiring the HEMS or EMS intervention was a congenital heart defect (31.41%). The most common medical emergency procedure performed by Polish Medical Air Rescue crew members for the neonatal patients was intravenous cannulation (43.07%). The odds ratio for congenital malformations was higher in male newborns. The type of Polish Medical Air Rescue mission was associated with the location of the call, time of the call, ICD-10 diagnosis associated with the dispatch, selected clinical findings, most commonly performed medical emergency procedures, and mission duration and distance covered.
Background and Objectives: Massive extremity haemorrhage remains the leading cause of preventable death on the battlefield and among trauma victims in civilian settings. Tourniquets are an effective, low-cost tool used to rapidly control bleeding. However, the availability of certified tourniquet models during a full-scale armed conflict can be significantly limited. This favours the emergence of locally manufactured devices. The aim of this study was to compare the effectiveness of the DNIPRO Gen 2 and SICH tourniquets with the CAT Gen 7 and SOFTT W Gen 4 tourniquets recommended by the Committee on Tactical Combat Casualty Care. Materials and Methods: The study included 51 Ukrainian medics experienced in prehospital care. Application speed was measured with a stopwatch, and occlusion success was confirmed by Doppler ultrasound. Pain was measured using the NRS, and participants were also able to provide subjective comments regarding the ergonomics and design of the tourniquets. Results: The four tourniquets tested demonstrated different occlusion success rates in arm and leg application. In upper extremity application, the SICH had the highest success rate (98.0%) and was associated with higher odds of successful application compared with the SOFTT-W Gen 4 (OR 25.14). In lower extremity application, the CAT Gen 7 had the highest rate of success (94.1%) and was 7.5 times more likely to achieve occlusion than the SOFTT-W Gen 4 (OR 7.54). The DNIPRO Gen 2 was rated most painful (Median 6), with significantly lower pain levels reported for the SICH (Median 4), the CAT Gen 7 (Median 5), and the SOFTT-W Gen 4 (Median 4). Conclusions: The DNIPRO Gen 2 and SICH tourniquets demonstrated high occlusion success rates, comparable to the CAT Gen 7 and superior to the SOFTT-W Gen 4. These findings suggest that Ukrainian-manufactured tourniquets may demonstrate comparable performance to CoTCCC-recommended tourniquets in a simulated prehospital setting.