Florian Thomas Kriwanek

Dr. Florian Thomas Kriwanek

Medical University of Vienna, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Cancers
Verified
Journal Article
Open access
PDF file
FKFlorian Thomas Kriwanek
Florian Thomas Kriwanek
LULeo Ulbrich
Leo Ulbrich
WLWolfgang Lechner
Wolfgang Lechner
CLCarola Lütgendorf-Caucig
Carola Lütgendorf-Caucig
SKStefan Konrad
Stefan Konrad
IRIvo Rausch
Ivo Rausch
Aim: The aim of this study was to assess the effects of including somatostatin receptor agonist (SSTR) PET imaging in meningioma radiotherapy planning by means of changes in inter-observer variability (IOV). Further, the possibility of using threshold-based delineation approaches for semiautomatic tumor volume definition was assessed. Patients and Methods: Sixteen patients with meningioma undergoing fractionated radiotherapy were delineated by five radiation oncologists. IOV was calculated by comparing each delineation to a consensus delineation, based on the simultaneous truth and performance level estimation (STAPLE) algorithm. The consensus delineation was used to adapt a threshold-based delineation, based on a maximization of the mean Dice coefficient. To test the threshold-based approach, seven patients with SSTR-positive meningioma were additionally evaluated as a validation group. Results: The average Dice coefficients for delineations based on MRI alone was 0.84 ± 0.12. For delineation based on MRI + PET, a significantly higher dice coefficient of 0.87 ± 0.08 was found (p < 0.001). The Hausdorff distance decreased from 10.96 ± 11.98 mm to 8.83 ± 12.21 mm (p < 0.001) when adding PET for the lesion delineation. The best threshold value for a threshold-based delineation was found to be 14.0% of the SUVmax, with an average Dice coefficient of 0.50 ± 0.19 compared to the consensus delineation. In the validation cohort, a Dice coefficient of 0.56 ± 0.29 and a Hausdorff coefficient of 27.15 ± 21.54 mm were found for the threshold-based approach. Conclusions: SSTR-PET added to standard imaging with CT and MRI reduces the IOV in radiotherapy planning for patients with meningioma. When using a threshold-based approach for PET-based delineation of meningioma, a relatively low threshold of 14.0% of the SUVmax was found to provide the best agreement with a consensus delineation.