For decades high voltage alternating current (HVAC) was considered as most economical solution to transmit and deliver electric power. With the recent developments in power electronic devices, high voltage direct current (HVDC) system becomes most prominent technology. Multi-terminal direct current (MTDC) based system as a promising technology for future power system is the major focus area for researchers and industries these days. A number of MTDC systems have been implemented physically. The major motivation to construct such MTDC systems is the integration of large-scale offshore power sources such as wind turbines and solar systems. This paper discusses the most critical challenges and issues related to operation, control and protection schemes for integration of modular multi-level converter (MMC) based MTDC systems. At first detailed literature survey has been presented to show the challenges for MMC based MTDC systems, then an analysis related to those challenges for operation, control and protection schemes for existing MMC based MTDC systems has been provided. Finally, a road map to tackle such challenges has been suggested.
Historically, the power system has relied on synchronous generators (SGs) to provide inertia and maintain grid stability. However, because of the increased integration of power-electronics-interfaced renewable energy sources, the grid’s stability has been challenged in the last decade due to a lack of inertia. Currently, the system predominantly uses grid-following (GFL) converters, built on the assumption that inertial sources regulate the system stability. Such an assumption does not hold for the low-inertia grids of the future. Grid-forming (GFM) converters, which mimic the traditional synchronous machinery’s functionalities, have been identified as a potential solution to support the low-inertia grids. The performance analysis of GFM converters for small-signal instability can be found in the literature, but large-signal instability is still an open research question. Moreover, various topologies and configurations of GFM converters have been proposed. Still, no comparative study combining all GFC configurations from the perspective of large-signal stability issues can be found. This paper combines and compares all the existing GFM control schemes from the perspective of large-signal stability issues to pave the way for future research and development of GFM converters for large-signal stability analysis and stabilization of the future low-inertia grids.
The adoption of electric vehicles (EVs) is increasing due to governmental policies focused on curbing climate change. EV batteries are retired when they are no longer suitable for energy-intensive EV operations. A large number of EV batteries are expected to be retired in the next 5–10 years. These retired batteries have 70–80% average capacity left. Second-life use of these battery packs has the potential to address the increasing energy storage system (ESS) demand for the grid and also to create a circular economy for EV batteries. The needs of modern grids for frequency regulation, power smoothing, and peak shaving can be met using retired batteries. Moreover, these batteries can also be employed for revenue generation for energy arbitrage (EA). While there are articles reviewing the general applications of retired batteries, this paper presents a comprehensive review of the research work on applications of the second-life batteries (SLBs) specific to the power grid and SLB degradation. The power electronics interface and battery management systems for the SLB are also thoroughly reviewed.
Grid-connected converters (GCCs) are used extensively for the integration of DC power sources with AC power sources. However, since it is a complex topic, there are many possibilities for regulating grid-injected currents, as well as different modulation techniques for generating full-bridge PWM voltages. The control techniques are directly related to the type of output filter, as well as to the topology of the converter, since a complex plant can require more sophisticated controllers to keep the system stable, and with good regulation performance. Furthermore, a discussion of the applicability of these converters in weak and very weak grids with high inductance content has recently been growing, which adds a greater degree of complexity to the control structure of the converter. In this brief overview are outlined some topics about topologies, output filters, and control, focusing on the current regulation of grid-connected converters. In addition, a discussion of the main challenges and critical areas in operating on weak and very weak grids is also presented.
Second-order ripples occur in the voltage and current during any DC–AC power conversion. These conversions occur in the voltage source inverters (VSIs), current source inverters (CSIs), and various single-stage inverters (SSIs) topologies. The second-order ripples lead to oscillating source node currents and DC bus voltages when there is an interconnection between the AC and DC microgrids or when an AC load is connected to the DC bus of the microgrid. Second-order ripples have various detrimental effects on the sources and the battery storage. In the storage battery, they lead to the depletion of electrodes. They also lead to stress in the converter or inverter components. This may lead to the failure of a component and hence affect the reliability of the system. Furthermore, the second-order ripple currents (SRCs) lead to ripple torque in wind turbines and lead to mechanical stress. SRCs cause a rise in the temperature of photovoltaic panels. An increase in the temperature of PV panels leads to a reduction in the power generated. Furthermore, the second-order voltage and current oscillations lead to a varying maximum power point in PV panels. Hence, the maximum power may not be extracted from it. To mitigate SRCs, oversizing of the components is needed. To improve the lifespan of the sources, storage, and converter components, the SRCs must be mitigated or kept within the desired limits. In the literature, different methodologies have been proposed to mitigate and regulate these second-order ripple components. This manuscript presents a comprehensive review of different effects of second-order ripples on different sources and the methodologies adopted to mitigate the ripples. Different active power decoupling methodologies, virtual impedance-based methodologies, pulse width modulation-based signal injection methodologies, and control methods adopted in distributed power generation methods for DC microgrids have been presented. The application of ripple control methods spans from single converters such as SSIs and VSIs to a network of interconnected converters. Furthermore, different challenges in the field of virtual impedance control and ripple mitigation in distributed power generation environments are discussed. This paper brings a review regarding control methodologies to mitigate and regulate second-order ripples in DC–AC conversions and microgrids.
8 October 2020 in Journal of Electrical Engineering & Technology