Peng Du

Dr. Peng Du

Hebei University of Engineering, Handan, Hebei, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2016 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
ZCZhenggang Cao
Zhenggang Cao
PDPeng Du
Peng Du
ZCZheming Chen
Zheming Chen
ZWZongshuai Wan
Zongshuai Wan

26 July 2016 in Advances in Structural Engineering
Verified
Journal Article
Closed access
CZCao Zhenggang
Cao Zhenggang
PDPeng Du
Peng Du
FFFan Feng
Fan Feng
FMFang Ming
Fang Ming
The influence of autoclaved aerated concrete panels on the mechanical properties of fabricated steel frames was experimentally investigated. Two fabricated steel frame specimens, which were with and without autoclaved aerated concrete panels, respectively, were tested under reversed cyclic loads. They were 1/2-scale, two-storey, and single-bay steel frames that were assembled by bolted beam-height adjustable steel beam-to-column connections. The effect of autoclaved aerated concrete panel dimensions on the mechanical behavior of infilled frames was also parametrically analyzed with the proposed numerical models which were verified on the basis of experimental data. The results indicate that the fabricated steel frames, assembled by beam-height adjustable connections, could behave in a ductile manner with sufficient stiffness and strength under cyclic loads; compared with bare steel frames, autoclaved aerated concrete panels could postpone the failure of structures and increase their initial stiffness, peak load, and energy dissipation capacity; moreover, the geometric details of autoclaved aerated concrete panels could significantly change the mechanical properties of infilled steel frames.

31 March 2017 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
ZCZhenggang Cao
Zhenggang Cao
PDPeng Du
Peng Du
FFFeng Fan
Feng Fan
JLJiangdong Li
Jiangdong Li

9 June 2017 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
PDF file
ZCZheng-Gang Cao
Zheng-Gang Cao
PDPeng Du
Peng Du
FFFeng Fan
Feng Fan
ZCZhe-Ming Chen
Zhe-Ming Chen
A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic performance. The specimen was a three-storey single-bay frame, which was composed of H-section steel columns and composite beams, and was assembled by bolted height-adjustable steel beam-to-column connections (BHA connections). Beam-only-connected SPSWs were selected as lateral load resisting members. The specimen was subjected to four ground motions of progressively increasing intensity. The results showed that: (1) beam-only-connected SPSWs provided sufficient lateral load resistance, lateral stiffness, and energy dissipation capacity to the fabricated frame via the tension field action developed in their infill panels; (2) the fabricated frame, assembled by BHA connections, exhibited substantial redundancy and good ductility; (3) an undesirable failure mode of the fabricated frame, in huge earthquakes, included severe cracking in composite beams and block shear failure in SPSWs’ connections; (4) the inter-storey shear force distribution determined by ASCE/SEI 7-10 was verified with experimental data.