Francisco Macedo Júnior

Prof. Francisco Macedo Júnior

State University of Feira de Santana, Feira de Santana, Bahia, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2022 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
EREvaldo A. Rodrigues
Evaldo A. Rodrigues
Daniel CostaDaniel Costa
Daniel Costa
FJFrancisco Macedo Júnior
Francisco Macedo Júnior
LDLeila T. B. L. Dantas
Leila T. B. L. Dantas
GDGustavo De-Deus
Gustavo De-Deus
ESEmmanuel Silva
Emmanuel Silva
Endodontic reciprocating motors are largely used to support a series of procedures in dentistry treatments, useful for those different circular movement patterns. In the last years, different motors have been available on the market, with varying costs and promised performance for the users; however, since their reciprocating angles and rotation speeds may have significant outcomes on the employed endodontic files, there should be an affordable and practical way to assess the actual performance of such motors concerning their expected operation. Actually, endodontic files attached to reciprocating motors will move too fast to be easily accounted, which has fostered the development of computational methods to allow the proper validation of their movements according to their official datasheets. In this scenario, this paper describes a feasible method to detect the movement patterns of different reciprocating endodontic motors by the processing of a set of consecutive images taken by a high-speed camera. The performed experiments for three different off-the-shelf reciprocating endodontic motors showed that their actual movement characteristics are slightly different from their specifications, and that each considered motor has a particular movement pattern.

6 October 2026 in International Endodontic Journal
Verified
Journal Article
Open access
MCMarco Simões de Carvalho
Marco Simões de Carvalho
DODiogo da Silva Oliveira
Diogo da Silva Oliveira
ESEmmanuel Silva
Emmanuel Silva
FJFrancisco Macedo Júnior
Francisco Macedo Júnior
ESErick Miranda Souza
Erick Miranda Souza
GDGustavo De‐Deus
Gustavo De‐Deus
Aim: To evaluate the bond strength of the reformulated epoxy resin‐based sealer AH Plus Ribbon to gutta‐percha using a previously described microshear bond strength test, and to compare its performance with that of six commercially available endodontic sealers representing different chemical classes. Methodology: One hundred and forty gutta‐percha discs (10 mm × 2 mm) were fabricated from standardized sheets and randomly allocated to seven groups ( n = 10 microshear specimens per group, assembled from 20 discs) according to the sealer evaluated: AH Plus Ribbon, AH Plus, EndoSequence BC Sealer, NeoSealer Flo, Pulp Canal Sealer, Endomethasone N and Sealapex. A standardized volume of sealer (0.1 mL) was placed between two gutta‐percha discs under a constant load (0.0981 N) for 200 s. After storage at 37°C for 7 days in contact with phosphate‐buffered saline‐moistened gauze, microshear bond strength was determined using a universal testing machine at a crosshead speed of 0.5 mm/min. Bond strength values (MPa) were analysed by one‐way ANOVA and Tukey's HSD post hoc test ( α = 0.05). Results: No premature failures occurred during specimen preparation, storage, or testing. Sealer type significantly influenced bond strength to gutta‐percha ( p < 0.001). AH Plus Ribbon and AH Plus exhibited the highest bond strengths and did not differ significantly from each other ( p = 0.722). Pulp Canal Sealer and Endomethasone N showed intermediate bond strength, whereas EndoSequence BC Sealer, NeoSealer Flo and Sealapex exhibited the lowest values, with no significant differences among them ( p > 0.05). Conclusions: AH Plus Ribbon exhibited bond strength to gutta‐percha comparable to that of AH Plus and significantly higher than that of EndoSequence BC Sealer, NeoSealer Flo, Pulp Canal Sealer, Endomethasone N and Sealapex under the experimental conditions employed.